SMA Energy

My home. My energy. Our climate.
My home. My energy. Our climate.

Les mer ›

Støttede enheter

Flow-kort

Klikk på en enhet ovenfor for å kun vise relaterte Flow-kort.

Når …

Battery
Batterinivået ble endret
Battery
Strømmen ble endret
Battery
Spenningen ble endret
Battery
Den elektriska strømmen ble endret
Battery
Batteriladestatusen ble endret ...
Battery
Temperaturen endres
Energy Meter
Strømmen ble endret
Energy Meter
Strømmåleren ble endret
Energy Meter
Phase [[phase]] is utilized to [[percentageUtilized]]%
Energy summary
Strømmen ble endret
Energy summary
Strømmåleren ble endret
Inverter
Ønsket effekt ble endret
Inverter
Strømmen ble endret
Inverter
Spenningen ble endret
Inverter
Strømmåleren ble endret
Inverter
Condition changed to [[inverter_condition]]
Inverter
Operational status changed to [[inverter_status]]

Og …

Battery
Batteriladestatusen er ...
Energy Meter
Any phase is utilized above Utilization (%)%
Energy Meter
Phase ... is utilized above Utilization (%)%
Inverter
Daily yield is above Daily yield (kWh)
Inverter
Operational status contains Operational status
Inverter
Power is below Power (W)

Så …

Energy Meter
Set the export limit to Limit (%)
i
The limit is set in percentage of the total power of all PV inverters connected to the Home Manager device. The Home Manager device needs to be configured for this to work.
Inverter
Innstill ønsket effekt W
i
Dette bytter også ønsket effekt-modus til Homey. For elbilladere startes eller stoppes lading automatisk.
Inverter
Curtail active power to Percent (0–100) % of the manual power limit
i
Writes a curtailment percentage to register 40023. The value is applied as a fraction of the manual power limit (register 40915), e.g. 50 % of a 5000 W limit = 2500 W. This is SMA's intended pattern for repeated/automated power control and does NOT wear the flash memory. PREREQUISITES: External control must be enabled and a fallback value/time configured in EnnexOS or Sunny Portal beforehand. If no write occurs within the fallback time (typically 10 min), the inverter automatically returns to 100 %. Sufficient user rights (installer level) are required to enable external control.
Inverter
Limit the active power output to Power (W)
i
Writes the manual active power limit to the inverter's flash memory (register 40915). WARNING: SMA's flash memory has a finite write count. After ~1000 lifetime parameter writes the inverter restricts further changes to 1 per 20 operating hours, to protect the hardware from final damage. Use this action sparingly (e.g. one-time setup or rare adjustments). For continuous or flow-based control, use the 'Set active power curtailment (%)' action instead, which writes to a dedicated curtailment register without flash wear.

Kontrollprogrammer

Du kan legge kontrollprogrammene for denne appen til dashboard eller startskjermen i mobilappen.

Realtime Energy Summary
Realtime Energy Summary

Støtte

Har du et problem med denne appen? Kontakt utvikleren her.

Nyheter

Versjon 2.9.0 — New action 'Set active power curtailment (%)' for repeated/automated inverter control without flash memory wear (writes register 40023). Requires external control to be enabled in EnnexOS or Sunny Portal beforehand. The existing 'Limit the active power output' action remains for one-time setup; its hint now clearly warns about flash wear with repeated use.

Vis endringslogg

SMA Energy

SMA Energy er ikke kompatibel med den valgte Homey.

SMA Energy vil straks installeres på Homey.
Installer