SMA Energy

My home. My energy. Our climate.
My home. My energy. Our climate.

Leer más ›

Dispositivos compatibles

Tarjetas Flow

Haz clic en el dispositivo de arriba para mostrar solo las tarjetas Flow relacionadas.

Cuando...

Battery
El nivel de la batería ha cambiado
Battery
La potencia ha cambiado
Battery
La tensión ha cambiado
Battery
La corriente eléctrica ha cambiado
Battery
El estado de carga de la batería ha cambiado ...
Battery
La temperatura ha cambiado
Energy Meter
La potencia ha cambiado
Energy Meter
El contador de energía ha cambiado
Energy Meter
Phase [[phase]] is utilized to [[percentageUtilized]]%
Energy summary
La potencia ha cambiado
Energy summary
El contador de energía ha cambiado
Inverter
La potencia objetivo ha cambiado
Inverter
La potencia ha cambiado
Inverter
La tensión ha cambiado
Inverter
El contador de energía ha cambiado
Inverter
Condition changed to [[inverter_condition]]
Inverter
Operational status changed to [[inverter_status]]

Y...

Battery
El estado de carga de la batería es ...
Energy Meter
Any phase is utilized above Utilization (%)%
Energy Meter
Phase ... is utilized above Utilization (%)%
Inverter
Daily yield is above Daily yield (kWh)
Inverter
Operational status contains Operational status
Inverter
Power is below Power (W)

Entonces...

Energy Meter
Set the export limit to Limit (%)
i
The limit is set in percentage of the total power of all PV inverters connected to the Home Manager device. The Home Manager device needs to be configured for this to work.
Inverter
Establecer la potencia objetivo W
i
Esto también cambia el modo de potencia objetivo a Homey. En el caso de cargadores de vehículos eléctricos, la carga se inicia o detiene automáticamente.
Inverter
Curtail active power to Percent (0–100) % of the manual power limit
i
Writes a curtailment percentage to register 40023. The value is applied as a fraction of the manual power limit (register 40915), e.g. 50 % of a 5000 W limit = 2500 W. This is SMA's intended pattern for repeated/automated power control and does NOT wear the flash memory. PREREQUISITES: External control must be enabled and a fallback value/time configured in EnnexOS or Sunny Portal beforehand. If no write occurs within the fallback time (typically 10 min), the inverter automatically returns to 100 %. Sufficient user rights (installer level) are required to enable external control.
Inverter
Limit the active power output to Power (W)
i
Writes the manual active power limit to the inverter's flash memory (register 40915). WARNING: SMA's flash memory has a finite write count. After ~1000 lifetime parameter writes the inverter restricts further changes to 1 per 20 operating hours, to protect the hardware from final damage. Use this action sparingly (e.g. one-time setup or rare adjustments). For continuous or flow-based control, use the 'Set active power curtailment (%)' action instead, which writes to a dedicated curtailment register without flash wear.

Widgets

Puedes añadir los widgets de esta aplicación a tu cuadro de mando o a la pantalla de inicio desde la aplicación móvil.

Realtime Energy Summary
Realtime Energy Summary

Asistencia

¿Tienes algún problema con esta aplicación? Contacta con el desarrollador aquí.

Novedades

Versión 2.9.0 — New action 'Set active power curtailment (%)' for repeated/automated inverter control without flash memory wear (writes register 40023). Requires external control to be enabled in EnnexOS or Sunny Portal beforehand. The existing 'Limit the active power output' action remains for one-time setup; its hint now clearly warns about flash wear with repeated use.

Ver registro de cambios

SMA Energy

SMA Energy no es compatible con el Homey seleccionado.

SMA Energy se instalará en Homey en breve.
Instalar