Sensible lets the heat pump you already have in Homey regulate on the temperature where you actually are, not up by the ceiling. It learns how far the heat pump's own sensor is off compared to your room sensors and corrects the setpoint by exactly that, so the heat pump keeps running steadily at low power where it is most efficient – like a Sensibo with a room sensor, without extra hardware.
Add a Sensible heating device, choose the heat pump and one or more room sensors, and use it like any thermostat. Optional extras include away and night temperatures, vacation mode, fireplace detection, a power meter, emergency and cold weather fan, and pause on open windows. Sensible also works with panel heaters and floor heating thermostats, so the whole house can be controlled the same way. Questions and details are in the Sensible topic on the Homey Community Forum.
Read more ›
Flow cards
Click on a device above to show related Flow cards only.
When...
Sensible heating
The target temperature changed
Sensible heating
The temperature changes
Sensible heating
Turned on
Sensible heating
Turned off
Sensible heating
Started heating
Sensible heating
Stopped heating
Sensible heating
Paused because a window opened
Sensible heating
Resumed after window closed
Sensible heating
Room sensor stopped reporting
Sensible heating
The room is colder than 5 °C while the thermostat is off
Sensible heating
Room sensor is back
Sensible heating
The heater cannot keep up
And...
Sensible heating
Is turned on
Sensible heating
Is heating
Sensible heating
Away mode is on
Sensible heating
Is paused by an open window
Sensible heating
Room with fireplace is on
Sensible heating
A fire is detected
Sensible heating
The heater cannot keep up
Then...
Sensible heating
Set the temperature °C
Sensible heating
Turn off
Sensible heating
Toggle on or off
Sensible heating
... cooling
Sensible heating
Turn away mode ...
Sensible heating
Set 23 °C for 60 minutes
Sensible heating
Turn off in 60 minutes
Sensible heating
Cancel timer
Sensible heating
Turn window pause ...
Sensible heating
Turn soft adjustment ...
Sensible heating
Turn room with fireplace ...
Sensible heating
The fire is ...
Sensible heating
Forget what Sensible has learned
Sensible heating
Turn emergency fan ...
Sensible heating
Turn frost protection ...
Sensible heating
Turn cold weather fan ...
Support
Having an issue with this app?
Contact the developer via the developer website.
What’s new
Version 1.25.0 — Heat pumps keep running at low power near the target: unless the room is clearly too warm, Sensible no longer takes the setpoint more than 0.5 °C below what the heat pump reads at the target (an inverter stops when its setpoint is below its own reading, so the room fell and it started again – thanks to a tester for the detailed analysis). New settings: Highest setpoint sent to the heater, and how far below its reading a heat pump may be set. New: Forget what is learned (configuration page and flow card), for example after moving the room sensor. Heat pumps with a power meter now learn how fast the room warms up also while the inverter modulates at low power (before, only high power counted, so many heat pumps never learned it – which the predictive brake and Smart start need). Less overshoot after a long time below the target: when the room reaches the target, the built-up correction is halved at once instead of slowly unwinding.