Sensible

Your heat pump, regulated on the temperature where you are

Avertissement ! Cette appli peut ne pas fonctionner correctement.

Cette appli est en cours de test, et n’a jamais été revue. Il se peut qu’elle ne fonctionne pas comme attendu.
Prenez des précautions supplémentaires en installant cette appli.

« Retour à la version normale

Your heat pump, regulated on the temperature where you are

Lire plus ›

Appareils pris en charge

Cartes Flow

Cliquez sur un appareil ci-dessus pour afficher uniquement les cartes Flow associées.

Quand...

Sensible heating
La température cible a été modifiée
Sensible heating
La température a changé
Sensible heating
Activé
Sensible heating
Désactivé
Sensible heating
Started heating
Sensible heating
Stopped heating
Sensible heating
Paused because a window opened
Sensible heating
Resumed after window closed
Sensible heating
Room sensor stopped reporting
i
No room sensor has reported for 2 hours. Meanwhile the heaters are set to the target and regulate themselves. Check the battery or the connection.
Sensible heating
The room is colder than 5 °C while the thermostat is off
i
Frost alert, for example for a cabin where frost protection is off on purpose. Runs once each time the room falls below the temperature while the Sensible thermostat is off.
Sensible heating
Room sensor is back
Sensible heating
The heater cannot keep up
i
The heater has worked hard for a while without bringing the room to the target – e.g. low fan speed, an open door or a very cold night.

Et...

Sensible heating
Est activé
Sensible heating
Is heating
Sensible heating
Away mode is on
Sensible heating
Is paused by an open window
Sensible heating
Room with fireplace is on
Sensible heating
A fire is detected
i
Room with fireplace: Sensible has detected (or a flow has said) that the fire is lit.
Sensible heating
The heater cannot keep up

Alors...

Sensible heating
Définir la température °C
Sensible heating
Activer
Sensible heating
Désactiver
Sensible heating
Alterner activé ou désactivé
Sensible heating
... cooling
Sensible heating
Turn away mode ...
Sensible heating
Set 23 °C for 60 minutes
Sensible heating
Turn off in 60 minutes
Sensible heating
Cancel timer
Sensible heating
Turn window pause ...
Sensible heating
Turn soft adjustment ...
Sensible heating
Turn room with fireplace ...
i
With it on, Sensible detects by itself when the fire is lit.
Sensible heating
The fire is ...
i
Overrides the automatic detection, e.g. from a sensor or a button by the fireplace. "Lit" lasts until "out" or at most 8 hours.
Sensible heating
Forget what Sensible has learned
i
Starts learning this room and its heaters again (difference between heater and room, stop margin, warm-up speed, power profile, fan hold, setpoint step). Settings and chosen devices are kept. Useful after moving the room sensor or replacing the heater.
Sensible heating
Turn emergency fan ...
i
Emergency fan: when the room is far from the target or the heater cannot keep up, Sensible raises the fan speed step by step – faster the further away – and turns it down gently again afterwards.
Sensible heating
Turn frost protection ...
Sensible heating
Turn cold weather fan ...

Assistance

Vous avez un problème avec cette appli ? Contacter le développeur ici.

Nouveautés

Version 1.25.0 — Heat pumps keep running at low power near the target: unless the room is clearly too warm, Sensible no longer takes the setpoint more than 0.5 °C below what the heat pump reads at the target (an inverter stops when its setpoint is below its own reading, so the room fell and it started again – thanks to a tester for the detailed analysis). New settings: Highest setpoint sent to the heater, and how far below its reading a heat pump may be set. New: Forget what is learned (configuration page and flow card), for example after moving the room sensor. Heat pumps with a power meter now learn how fast the room warms up also while the inverter modulates at low power (before, only high power counted, so many heat pumps never learned it – which the predictive brake and Smart start need). Less overshoot after a long time below the target: when the room reaches the target, the built-up correction is halved at once instead of slowly unwinding.

Afficher le journal des modifications

Sensible

Cette appli peut gérer tout votre Homey.

Sensible n’est pas compatible avec le Homey sélectionné.

Sensible va s’installer sur Homey dans un instant.
Installer