Sensible

Your heat pump, regulated on the temperature where you are

¡Advertencia! Es posible que esta aplicación no funcione correctamente.

Esta aplicación se está probando y nunca se ha revisado. Puede que no funcione como se espera.
Ten mucho cuidado al instalar esta aplicación.

« Volver a la versión normal

Your heat pump, regulated on the temperature where you are

Leer más ›

Dispositivos compatibles

Tarjetas Flow

Haz clic en el dispositivo de arriba para mostrar solo las tarjetas Flow relacionadas.

Cuando...

Sensible heating
La temperatura deseada ha cambiado
Sensible heating
La temperatura ha cambiado
Sensible heating
Encendido
Sensible heating
Apagado
Sensible heating
Started heating
Sensible heating
Stopped heating
Sensible heating
Paused because a window opened
Sensible heating
Resumed after window closed
Sensible heating
Room sensor stopped reporting
i
No room sensor has reported for 2 hours. Meanwhile the heaters are set to the target and regulate themselves. Check the battery or the connection.
Sensible heating
The room is colder than 5 °C while the thermostat is off
i
Frost alert, for example for a cabin where frost protection is off on purpose. Runs once each time the room falls below the temperature while the Sensible thermostat is off.
Sensible heating
Room sensor is back
Sensible heating
The heater cannot keep up
i
The heater has worked hard for a while without bringing the room to the target – e.g. low fan speed, an open door or a very cold night.

Y...

Sensible heating
Está encendido
Sensible heating
Is heating
Sensible heating
Away mode is on
Sensible heating
Is paused by an open window
Sensible heating
Room with fireplace is on
Sensible heating
A fire is detected
i
Room with fireplace: Sensible has detected (or a flow has said) that the fire is lit.
Sensible heating
The heater cannot keep up

Entonces...

Sensible heating
Ajustar la temperatura °C
Sensible heating
Encender
Sensible heating
Apagar
Sensible heating
Encender o apagar
Sensible heating
... cooling
Sensible heating
Turn away mode ...
Sensible heating
Set 23 °C for 60 minutes
Sensible heating
Turn off in 60 minutes
Sensible heating
Cancel timer
Sensible heating
Turn window pause ...
Sensible heating
Turn soft adjustment ...
Sensible heating
Turn room with fireplace ...
i
With it on, Sensible detects by itself when the fire is lit.
Sensible heating
The fire is ...
i
Overrides the automatic detection, e.g. from a sensor or a button by the fireplace. "Lit" lasts until "out" or at most 8 hours.
Sensible heating
Forget what Sensible has learned
i
Starts learning this room and its heaters again (difference between heater and room, stop margin, warm-up speed, power profile, fan hold, setpoint step). Settings and chosen devices are kept. Useful after moving the room sensor or replacing the heater.
Sensible heating
Turn emergency fan ...
i
Emergency fan: when the room is far from the target or the heater cannot keep up, Sensible raises the fan speed step by step – faster the further away – and turns it down gently again afterwards.
Sensible heating
Turn frost protection ...
Sensible heating
Turn cold weather fan ...

Asistencia

¿Tienes algún problema con esta aplicación? Contacta con el desarrollador aquí.

Novedades

Versión 1.25.0 — Heat pumps keep running at low power near the target: unless the room is clearly too warm, Sensible no longer takes the setpoint more than 0.5 °C below what the heat pump reads at the target (an inverter stops when its setpoint is below its own reading, so the room fell and it started again – thanks to a tester for the detailed analysis). New settings: Highest setpoint sent to the heater, and how far below its reading a heat pump may be set. New: Forget what is learned (configuration page and flow card), for example after moving the room sensor. Heat pumps with a power meter now learn how fast the room warms up also while the inverter modulates at low power (before, only high power counted, so many heat pumps never learned it – which the predictive brake and Smart start need). Less overshoot after a long time below the target: when the room reaches the target, the built-up correction is halved at once instead of slowly unwinding.

Ver registro de cambios

Sensible

Esta aplicación puede administrar todo tu Homey.

Sensible no es compatible con el Homey seleccionado.

Sensible se instalará en Homey en breve.
Instalar