Monitor your Deye solar inverter directly on your local network — no cloud account, no internet dependency.
This app communicates with the Solarman Wi-Fi data logger stick using the SolarmanV5 protocol over TCP port 8899, polling your inverter every 60 seconds.
SUPPORTED MODELS
- Deye Microinverter 2 MPPT (SUN600G3 / SUN800G3 / SUN1000G3)
- Deye Microinverter 4 MPPT (SUN2000G3)
- Deye String Inverter 3-phase, 2 MPPT
- Deye Hybrid Inverter with battery, 2 MPPT
- Deye Hybrid Inverter 3-phase SG04LP3 (SUN-8K / SUN-10K / SUN-12K-SG04LP3-EU)
REQUIREMENTS
- Homey Pro (firmware 13.0 or later)
- Solarman Wi-Fi data logger stick connected to your local network
- TCP port 8899 accessible from Homey (no firewall blocking)
AVAILABLE DATA
Depending on inverter model:
- Real-time AC output power (W)
- PV string voltage and current per channel (PV1–PV4)
- Grid voltage, current and frequency
- Inverter temperature
- Daily and total production (kWh)
- Battery power, voltage, current and state of charge (hybrid models)
- Grid import / export energy (hybrid models)
- Load power consumption (hybrid models)
- Fault / Alarm state
HOMEY ENERGY
Fully integrated with Homey Energy. Your inverter appears as a solar panel device and contributes to your energy dashboard automatically.
PAIRING
1. Open Homey and add a new device
2. Leave the IP field empty to auto-discover loggers on your network, or enter the IP manually
3. The logger serial number is detected automatically (or enter it manually from the sticker)
4. Select your inverter model from the list
5. Capabilities are configured automatically based on your model
NOTES
- Local communication only — no Deye cloud or SolarmanCloud required.
- Auto-discovery uses UDP broadcast on port 48899 (Solarman discovery protocol).
- Night-time detection pauses polling between sunset and sunrise to avoid false unavailability alerts.
- Inverter definitions based on the home_assistant_solarman open-source project.
Klikk på en enhet ovenfor for å kun vise relaterte Flow-kort.
Når …
Deye Vekselretter
Batteriet begynte å lade
i
Triggered when the battery transitions from discharging or standby to charging.
Deye Vekselretter
Batteriet begynte å utlade
i
Triggered when the battery transitions from charging or standby to discharging.
Deye Vekselretter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
Deye Vekselretter
Vekselretter-data oppdatert
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
Deye Vekselretter
Feil/alarm oppdaget
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
Deye Vekselretter
Netteksport startet
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
Deye Vekselretter
Nettimport startet
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
Deye Vekselretter
Nettilkobling mistet
i
Triggered when the inverter reports a grid outage (hybrid models only).
Deye Vekselretter
Nettilkobling gjenopprettet
i
Triggered when the inverter reports grid power has returned (hybrid models only).
Deye Vekselretter
Loggeren gikk offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
Deye Vekselretter
Loggeren kom tilbake online
i
Triggered when the logger responds again after an offline period.
Deye Vekselretter
Solproduksjon startet
i
Triggered when the inverter starts producing power (e.g. at sunrise).
Deye Vekselretter
Solproduksjon stoppet
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).
SOFAR Vekselretter
Batteriet begynte å lade
i
Triggered when the battery transitions from discharging or standby to charging.
SOFAR Vekselretter
Batteriet begynte å utlade
i
Triggered when the battery transitions from charging or standby to discharging.
SOFAR Vekselretter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
SOFAR Vekselretter
Vekselretter-data oppdatert
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
SOFAR Vekselretter
Feil/alarm oppdaget
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
SOFAR Vekselretter
Netteksport startet
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
SOFAR Vekselretter
Nettimport startet
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
SOFAR Vekselretter
Nettilkobling mistet
i
Triggered when the inverter reports a grid outage (hybrid models only).
SOFAR Vekselretter
Nettilkobling gjenopprettet
i
Triggered when the inverter reports grid power has returned (hybrid models only).
SOFAR Vekselretter
Loggeren gikk offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
SOFAR Vekselretter
Loggeren kom tilbake online
i
Triggered when the logger responds again after an offline period.
SOFAR Vekselretter
Solproduksjon startet
i
Triggered when the inverter starts producing power (e.g. at sunrise).
SOFAR Vekselretter
Solproduksjon stoppet
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).
Og …
Deye Vekselretter
Batteri SOC er over ...%
i
Kun tilgjengelig på hybridinvertere med en paret batterienhet.
Deye Vekselretter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
Deye Vekselretter
Feil/alarm er aktiv
Deye Vekselretter
Batteriet lades
i
Kun tilgjengelig på hybridinvertere med en paret batterienhet.
Deye Vekselretter
Vekselretteren mater nettet
i
Kun tilgjengelig på hybridinvertere med CT-klemme og nettimport/-eksport aktivert under paring.
Deye Vekselretter
Solproduksjon er aktiv
SOFAR Vekselretter
Batteri SOC er over ...%
i
Kun tilgjengelig på hybridinvertere med en paret batterienhet.
SOFAR Vekselretter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
SOFAR Vekselretter
Feil/alarm er aktiv
SOFAR Vekselretter
Batteriet lades
i
Kun tilgjengelig på hybridinvertere med en paret batterienhet.
SOFAR Vekselretter
Vekselretteren mater nettet
i
Kun tilgjengelig på hybridinvertere med CT-klemme og nettimport/-eksport aktivert under paring.
SOFAR Vekselretter
Solproduksjon er aktiv
Kontrollprogrammer
Du kan legge kontrollprogrammene for denne appen til dashboard eller startskjermen i mobilappen.
Energioversikt
Støtte
Har du et problem med denne appen?
Kontakt utvikleren her.
Nyheter
Versjon 1.4.15 — New maintenance action "Restore capabilities" (device settings → Maintenance): re-adds missing values, such as advanced sensors skipped at pairing (e.g. house load power, L2/L3), with their correct names — on the same device, without re-pairing and without removing anything, so Flows and Insights are kept. The repair screen's "Add advanced sensors" option uses the same logic.