Monitor your Deye solar inverter directly on your local network — no cloud account, no internet dependency.
This app communicates with the Solarman Wi-Fi data logger stick using the SolarmanV5 protocol over TCP port 8899, polling your inverter every 60 seconds.
SUPPORTED MODELS
- Deye Microinverter 2 MPPT (SUN600G3 / SUN800G3 / SUN1000G3)
- Deye Microinverter 4 MPPT (SUN2000G3)
- Deye String Inverter 3-phase, 2 MPPT
- Deye Hybrid Inverter with battery, 2 MPPT
- Deye Hybrid Inverter 3-phase SG04LP3 (SUN-8K / SUN-10K / SUN-12K-SG04LP3-EU)
REQUIREMENTS
- Homey Pro (firmware 13.0 or later)
- Solarman Wi-Fi data logger stick connected to your local network
- TCP port 8899 accessible from Homey (no firewall blocking)
AVAILABLE DATA
Depending on inverter model:
- Real-time AC output power (W)
- PV string voltage and current per channel (PV1–PV4)
- Grid voltage, current and frequency
- Inverter temperature
- Daily and total production (kWh)
- Battery power, voltage, current and state of charge (hybrid models)
- Grid import / export energy (hybrid models)
- Load power consumption (hybrid models)
- Fault / Alarm state
HOMEY ENERGY
Fully integrated with Homey Energy. Your inverter appears as a solar panel device and contributes to your energy dashboard automatically.
PAIRING
1. Open Homey and add a new device
2. Leave the IP field empty to auto-discover loggers on your network, or enter the IP manually
3. The logger serial number is detected automatically (or enter it manually from the sticker)
4. Select your inverter model from the list
5. Capabilities are configured automatically based on your model
NOTES
- Local communication only — no Deye cloud or SolarmanCloud required.
- Auto-discovery uses UDP broadcast on port 48899 (Solarman discovery protocol).
- Night-time detection pauses polling between sunset and sunrise to avoid false unavailability alerts.
- Inverter definitions based on the home_assistant_solarman open-source project.
Klik på en enhed ovenfor for kun at vise relaterede Flow-kort.
Når...
Deye Inverter
Batteriet begyndte at oplade
i
Triggered when the battery transitions from discharging or standby to charging.
Deye Inverter
Batteriet begyndte at aflade
i
Triggered when the battery transitions from charging or standby to discharging.
Deye Inverter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
Deye Inverter
Inverterdata opdateret
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
Deye Inverter
Fejl/alarm registreret
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
Deye Inverter
Neteksport startet
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
Deye Inverter
Netimport startet
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
Deye Inverter
Nettilslutning mistet
i
Triggered when the inverter reports a grid outage (hybrid models only).
Deye Inverter
Nettilslutning genoprettet
i
Triggered when the inverter reports grid power has returned (hybrid models only).
Deye Inverter
Loggeren gik offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
Deye Inverter
Loggeren kom tilbage online
i
Triggered when the logger responds again after an offline period.
Deye Inverter
Solproduktion startet
i
Triggered when the inverter starts producing power (e.g. at sunrise).
Deye Inverter
Solproduktion stoppet
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).
SOFAR Inverter
Batteriet begyndte at oplade
i
Triggered when the battery transitions from discharging or standby to charging.
SOFAR Inverter
Batteriet begyndte at aflade
i
Triggered when the battery transitions from charging or standby to discharging.
SOFAR Inverter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
SOFAR Inverter
Inverterdata opdateret
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
SOFAR Inverter
Fejl/alarm registreret
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
SOFAR Inverter
Neteksport startet
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
SOFAR Inverter
Netimport startet
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
SOFAR Inverter
Nettilslutning mistet
i
Triggered when the inverter reports a grid outage (hybrid models only).
SOFAR Inverter
Nettilslutning genoprettet
i
Triggered when the inverter reports grid power has returned (hybrid models only).
SOFAR Inverter
Loggeren gik offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
SOFAR Inverter
Loggeren kom tilbage online
i
Triggered when the logger responds again after an offline period.
SOFAR Inverter
Solproduktion startet
i
Triggered when the inverter starts producing power (e.g. at sunrise).
SOFAR Inverter
Solproduktion stoppet
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).
Og...
Deye Inverter
Batteri SOC er over ...%
i
Kun tilgængelig på hybridinvertere med en paret batterienhed.
Deye Inverter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
Deye Inverter
Fejl/alarm er aktiv
Deye Inverter
Batteriet oplades
i
Kun tilgængelig på hybridinvertere med en paret batterienhed.
Deye Inverter
Inverteren leverer til nettet
i
Kun tilgængelig på hybridinvertere med CT-klemme og netimport/-eksport aktiveret under parring.
Deye Inverter
Solproduktion er aktiv
SOFAR Inverter
Batteri SOC er over ...%
i
Kun tilgængelig på hybridinvertere med en paret batterienhed.
SOFAR Inverter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
SOFAR Inverter
Fejl/alarm er aktiv
SOFAR Inverter
Batteriet oplades
i
Kun tilgængelig på hybridinvertere med en paret batterienhed.
SOFAR Inverter
Inverteren leverer til nettet
i
Kun tilgængelig på hybridinvertere med CT-klemme og netimport/-eksport aktiveret under parring.
SOFAR Inverter
Solproduktion er aktiv
Widgets
Du kan tilføje denne apps widgets til dit dashboard eller din startskærm i mobil-appen.
Energioversigt
Support
Har du et problem med denne app?
Kontakt udvikleren her.
Hvad er nyt
Version 1.4.15 — New maintenance action "Restore capabilities" (device settings → Maintenance): re-adds missing values, such as advanced sensors skipped at pairing (e.g. house load power, L2/L3), with their correct names — on the same device, without re-pairing and without removing anything, so Flows and Insights are kept. The repair screen's "Add advanced sensors" option uses the same logic.