Panasonic Aquarea via HeishaMon

Local control and monitoring of Panasonic Aquarea heat pumps through a HeishaMon MQTT gateway. Instant updates, COP and energy tracking, seven dashboard widgets and 41 Flow cards.

Attenzione! Questa app potrebbe non funzionare correttamente.

Questa app è in fase di test e non è mai stata recensita. Potrebbe non funzionare come previsto.
Fai molta attenzione quando installi questa app.

« Torna alla versione normale

Local control and monitoring of Panasonic Aquarea heat pumps through a HeishaMon MQTT gateway. Instant updates, COP and energy tracking, seven dashboard widgets and 41 Flow cards.

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Aquarea heat pump
La temperatura nominale è cambiata
Aquarea heat pump
La temperatura è cambiata
Aquarea heat pump
L'energia è cambiata
Aquarea heat pump
Il misuratore di potenza è cambiato
Aquarea heat pump
Defrost started
Aquarea heat pump
Defrost ended
Aquarea heat pump
Error code changed
Aquarea heat pump
3-way valve switched
Aquarea heat pump
Operating mode changed
Aquarea heat pump
COP changed
Aquarea heat pump
Daily COP calculated
i
Fires just after midnight with the completed day's energy-weighted COP.
Aquarea heat pump
Heating curve advice available
i
Fires when the app has learned enough to conclude your curve shape is off.
Aquarea heat pump
A command was sent to the heat pump
i
Fires for every write, including blocked ones in monitoring-only mode. Useful for logging what changed your heat pump and why.
Aquarea heat pump
Water flow dropped too low
i
Fires when the flow stays below your threshold while the compressor runs. Check the filter, air in the system, the circulation pump and whether enough zones are open.
Aquarea heat pump
Water pressure dropped too low
Aquarea heat pump
The heat pump is short cycling
Aquarea hot water
La temperatura nominale è cambiata
Aquarea hot water
La temperatura è cambiata
Aquarea hot water
L'energia è cambiata
Aquarea hot water
Sterilization state changed

E...

Aquarea heat pump
Is defrosting
Aquarea heat pump
Is heating hot water
Aquarea heat pump
Compressor is running
Aquarea heat pump
Has an error
Aquarea heat pump
Operating mode is ...
Aquarea heat pump
Today's COP is above ...
Aquarea heat pump
Heat pump is on
Aquarea heat pump
A price offset is active
Aquarea heat pump
Starts in the last hour is above ...
Aquarea hot water
Hot water is being forced

Poi...

Aquarea heat pump
Imposta la temperatura °C
Aquarea heat pump
Turn heat pump ...
Aquarea heat pump
Set operating mode to ...
Aquarea heat pump
Set zone ... ... request to ...
i
In compensation-curve mode this is a shift of -5 to +5 K; in direct mode it's the absolute setpoint.
Aquarea heat pump
Set hot water to ... °C
Aquarea heat pump
Set quiet mode to ...
Aquarea heat pump
Set powerful mode to ...
Aquarea heat pump
Turn force hot water ...
i
Only effective when the operating mode includes hot water (DHW only, Heat+DHW, Cool+DHW or Auto+DHW).
Aquarea heat pump
Turn holiday mode ...
Aquarea heat pump
Set ... backup heater to ...
Aquarea heat pump
Set zone ... curve: Target high/Target low °C at Outside low/Outside high °C outside
Aquarea heat pump
Force defrost
i
Asks the heat pump to defrost. It decides for itself whether the backup heater joins in; that is a setting in the unit, not something this app can change.
Aquarea heat pump
Force sterilization
Aquarea heat pump
Reset error code
Aquarea heat pump
Send Command = Value
i
Advanced: sends any documented SET topic directly. The value is validated against the documented range.
Aquarea heat pump
Reset energy meters
Aquarea heat pump
Set target temperature to ...
i
Accepts tenths of a degree. Requires fractional setpoints to be enabled in the device settings.
Aquarea heat pump
Room temperature is ... °C
i
Feed a Homey temperature sensor into the adaptive control loop. Trigger this whenever the sensor reports a new value.
Aquarea heat pump
Apply curve recommendation
i
Writes the learned slope correction to the zone 1 heating curve. Requires "Allow writing configuration" to be enabled.
Aquarea heat pump
Turn adaptive tuning ...
Aquarea heat pump
Shift the curve by Kelvin K for Minutes minutes (Reason (optional))
i
Adds to whatever the app is already doing and reverts by itself when the time is up, also after a restart. A new card replaces the previous offset.
Aquarea heat pump
Apply the ... offset for Minutes minutes
i
Uses the offsets you set under Price steering in the device settings.
Aquarea heat pump
Pause heating for Minutes minutes
i
Switches the heat pump off and back on when the time is up, also after a restart. Hot water is paused with it, so keep it short.
Aquarea heat pump
Clear the price offset
Aquarea heat pump
Forecast: Expected °C °C and Expected W/m² W/m² sun
i
Run this whenever your weather app has a new forecast for the coming hours. Leave the sun value at 0 if you only have a temperature.
Aquarea heat pump
Clear the weather forecast
Aquarea hot water
Imposta la temperatura °C
Aquarea hot water
Set hot water to ... °C
Aquarea hot water
Turn forced hot water ...
Aquarea hot water
Start sterilization

Widget

Puoi aggiungere i widget di questa app alla dashboard oppure alla schermata iniziale nell’app mobile.

Heat pump
Heat pump
Heat pump (compact)
Heat pump (compact)
Heat pump chart
Heat pump chart
Energy by hour
Energy by hour
Energy balance
Energy balance
Heat pump controls
Heat pump controls
Heating curve
Heating curve

Supporto

Hai un problema con questa app? Contatta lo sviluppatore qui.

Novità

Versione 1.17.1 — 1.14.0 — Fixed: running a fixed water temperature instead of a curve gave you a slider in kelvin rather than the temperature itself. Added: heat pumps that do not report which of the two they use are recognised from the value, and you can set it explicitly.

Visualizza il changelog

Panasonic Aquarea via HeishaMon

Panasonic Aquarea via HeishaMon non è compatibile con l’Homey selezionato.

Panasonic Aquarea via HeishaMonverrà installato a breve su Homey.
Installa