Panasonic Aquarea via HeishaMon

Local control and monitoring of Panasonic Aquarea heat pumps through a HeishaMon MQTT gateway. Instant updates, COP and energy tracking, seven dashboard widgets and 41 Flow cards.

Warning! This app might not work properly.

This app version is currently being tested, and has not yet been reviewed. It might not work as expected.
Be extra careful when installing this app.

« Back to the regular version

Local control and monitoring of Panasonic Aquarea heat pumps through a HeishaMon MQTT gateway. Instant updates, COP and energy tracking, seven dashboard widgets and 41 Flow cards.

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

Aquarea heat pump
The target temperature changed
Aquarea heat pump
The temperature changes
Aquarea heat pump
The power changed
Aquarea heat pump
The power meter changed
Aquarea heat pump
Defrost started
Aquarea heat pump
Defrost ended
Aquarea heat pump
Error code changed
Aquarea heat pump
3-way valve switched
Aquarea heat pump
Operating mode changed
Aquarea heat pump
COP changed
Aquarea heat pump
Daily COP calculated
i
Fires just after midnight with the completed day's energy-weighted COP.
Aquarea heat pump
Heating curve advice available
i
Fires when the app has learned enough to conclude your curve shape is off.
Aquarea heat pump
A command was sent to the heat pump
i
Fires for every write, including blocked ones in monitoring-only mode. Useful for logging what changed your heat pump and why.
Aquarea hot water
The target temperature changed
Aquarea hot water
The temperature changes
Aquarea hot water
The power changed
Aquarea hot water
Sterilization state changed

And...

Aquarea heat pump
Is defrosting
Aquarea heat pump
Is heating hot water
Aquarea heat pump
Compressor is running
Aquarea heat pump
Has an error
Aquarea heat pump
Operating mode is ...
Aquarea heat pump
Quiet mode is ...
Aquarea heat pump
Today's COP is above ...
Aquarea heat pump
Heat pump is on
Aquarea hot water
Hot water is being forced

Then...

Aquarea heat pump
Set the temperature °C
Aquarea heat pump
Turn heat pump ...
Aquarea heat pump
Set operating mode to ...
Aquarea heat pump
Set zone ... ... request to ...
i
In compensation-curve mode this is a shift of -5 to +5 K; in direct mode it's the absolute setpoint.
Aquarea heat pump
Set hot water to ... °C
Aquarea heat pump
Set quiet mode to ...
Aquarea heat pump
Set powerful mode to ...
Aquarea heat pump
Turn force hot water ...
i
Only effective when the operating mode includes hot water (DHW only, Heat+DHW, Cool+DHW or Auto+DHW).
Aquarea heat pump
Turn holiday mode ...
Aquarea heat pump
Set ... backup heater to ...
Aquarea heat pump
Set zone ... curve: Target high/Target low °C at Outside low/Outside high °C outside
Aquarea heat pump
Force defrost
Aquarea heat pump
Force sterilization
Aquarea heat pump
Reset error code
Aquarea heat pump
Send Command = Value
i
Advanced: sends any documented SET topic directly. The value is validated against the documented range.
Aquarea heat pump
Reset energy meters
Aquarea heat pump
Set target temperature to ...
i
Accepts tenths of a degree. Requires fractional setpoints to be enabled in the device settings.
Aquarea heat pump
Room temperature is ... °C
i
Feed a Homey temperature sensor into the adaptive control loop. Trigger this whenever the sensor reports a new value.
Aquarea heat pump
Apply curve recommendation
i
Writes the learned slope correction to the zone 1 heating curve. Requires "Allow writing configuration" to be enabled.
Aquarea heat pump
Turn adaptive tuning ...
Aquarea hot water
Set the temperature °C
Aquarea hot water
Set hot water to ... °C
Aquarea hot water
Turn forced hot water ...
Aquarea hot water
Start sterilization

Widgets

You can add this app’s widgets to your dashboard or homescreen in the mobile app.

Heat pump
Heat pump
Heat pump (compact)
Heat pump (compact)
Heat pump chart
Heat pump chart
Energy by hour
Energy by hour
Energy balance
Energy balance
Heat pump controls
Heat pump controls
Heating curve
Heating curve

Support

Having an issue with this app? Contact the developer via the developer website.

What’s new

Version 1.10.2 — Fixed: power, kWh and COP did not come through on K, L and M series. The heat pump now runs its boiler by itself and can no longer be switched off by flows or scenes that turn everything off; hot water is adjusted from the hot water device only. New: a monitoring-only mode and a log of every command sent. If you switched the heat pump with the standard on/off card, use Turn heat pump on/off instead.

View changelog

Panasonic Aquarea via HeishaMon

Panasonic Aquarea via HeishaMon is not compatible with the selected Homey.

Panasonic Aquarea via HeishaMon will install on Homey shortly.
Install App