Keep an eye on your Remeha heat pump and adjust it on the fly, all from Homey. See what your system is doing in real time and tweak settings whenever you need to. Use Flows to automate your comfort and save on energy costs.
Supports the Remeha Elga Ace Split, Monoblock and All-in-One models. You will need a GTW-08 gateway with an RS485-to-Ethernet adapter to get your heat pump on the network. Optionally pair it with a Homey power meter for complete energy insights.
Read more ›
Flow cards
Click on a device above to show related Flow cards only.
When...
Remeha Heat Pump
The thermostat mode changed to ...
Remeha Heat Pump
The target temperature changed
Remeha Heat Pump
The temperature changes
Remeha Heat Pump
The pressure changed
Remeha Heat Pump
The waterflow changed
Remeha Heat Pump
The power meter changed
Remeha Heat Pump
The power changed
Remeha Heat Pump
COP dropped below Threshold
Remeha Heat Pump
Defrost cycle started
Remeha Heat Pump
Defrost cycle ended
Remeha Heat Pump
An error was cleared
Remeha Heat Pump
An error occurred
Remeha Heat Pump
Hybrid mode changed
Remeha Heat Pump
Status changed to Status
And...
Remeha Heat Pump
The thermostat mode is ...
Remeha Heat Pump
Domestic hot water is active
Remeha Heat Pump
Heat pump has an active error
Remeha Heat Pump
Hybrid mode is Mode
Remeha Heat Pump
Heat pump is actively heating
Remeha Heat Pump
Heat pump is defrosting
Remeha Heat Pump
Heat pump status is Status
Then...
Remeha Heat Pump
Set the thermostat mode to ...
Remeha Heat Pump
Set the temperature °C
Remeha Heat Pump
Set energy to Energy in kWh kWh
Remeha Heat Pump
Set power to Power in watts W
Remeha Heat Pump
Set gas tariff to Tariff in ct/m³ ct/m³
Remeha Heat Pump
Set electricity off-peak tariff to Tariff in ct/kWh ct/kWh
Remeha Heat Pump
Set electricity peak tariff to Tariff in ct/kWh ct/kWh
Support
Having an issue with this app?
Contact the developer via the developer website.
What’s new
Version 1.1.1 — Bugfix release. All 7 Flow triggers introduced in 1.1.0 (defrost, error, status change, hybrid mode, COP threshold) now actually fire — a bug prevented every one of them from triggering. Changing the gateway IP address, port or slave ID in the device settings now works, with validation, instead of silently failing; no re-pairing needed. Hot water setpoint now offers the documented 35–65 °C range and room setpoint 5–30 °C — existing devices receive the corrected ranges automatically, no re-pairing needed. Fixed nonsense energy meter readings (such as 238 million kWh) when the gateway serves partially unavailable registers. Failed register writes now report an error instead of appearing to succeed. Faster polling thanks to a reduced Modbus inter-read delay. The device now identifies as a Heat Pump instead of a Thermostat — if a Flow card no longer matches your device, re-select the device in that card. Removed the misleading 15 W standby power estimate; use the external energy meter Flow integration for real power and energy readings. New device images and refreshed icons.
View changelog