Remeha

Make your heat pump work smarter, not harder
Make your heat pump work smarter, not harder

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Remeha Heat Pump
La modalità del termostato è cambiata ...
Remeha Heat Pump
La temperatura nominale è cambiata
Remeha Heat Pump
La temperatura è cambiata
Remeha Heat Pump
La pressione è cambiata
Remeha Heat Pump
Il flusso d'acqua è cambiato
Remeha Heat Pump
Il misuratore di potenza è cambiato
Remeha Heat Pump
L'energia è cambiata
Remeha Heat Pump
COP dropped below Threshold
i
Triggers once when the calculated COP crosses below the threshold (fires on the transition, not continuously).
Remeha Heat Pump
Defrost cycle started
i
Triggers when the heat pump enters a defrost cycle.
Remeha Heat Pump
Defrost cycle ended
i
Triggers when the heat pump finishes a defrost cycle.
Remeha Heat Pump
An error was cleared
i
Triggers when the heat pump returns to normal operation after an error.
Remeha Heat Pump
An error occurred
i
Triggers when the heat pump reports an error. Use the tokens to inspect the error code and priority.
Remeha Heat Pump
Hybrid mode changed
i
Triggers whenever the hybrid mode changes (auto / heat pump / boiler only).
Remeha Heat Pump
Status changed to Status
i
Triggers when the heat pump status transitions to the selected state.

E...

Remeha Heat Pump
La modalità del termostato è ...
Remeha Heat Pump
Domestic hot water is active
Remeha Heat Pump
Heat pump has an active error
Remeha Heat Pump
Hybrid mode is Mode
Remeha Heat Pump
Heat pump is actively heating
i
True when the compressor is running (status is Heat pump, Hybrid, or Defrost).
Remeha Heat Pump
Heat pump is defrosting
Remeha Heat Pump
Heat pump status is Status

Poi...

Remeha Heat Pump
Imposta la modalità ...
Remeha Heat Pump
Imposta la temperatura °C
Remeha Heat Pump
Set energy to Energy in kWh kWh
Remeha Heat Pump
Set power to Power in watts W
Remeha Heat Pump
Set gas tariff to Tariff in ct/m³ ct/m³
i
Warning: Do not change tariffs more than 6 times per day!
Remeha Heat Pump
Set electricity off-peak tariff to Tariff in ct/kWh ct/kWh
i
Warning: Do not change tariffs more than 6 times per day!
Remeha Heat Pump
Set electricity peak tariff to Tariff in ct/kWh ct/kWh
i
Warning: Do not change tariffs more than 6 times per day!

Supporto

Hai un problema con questa app? Contatta lo sviluppatore qui.

Novità

Versione 1.1.0 — Major Flow upgrade: 7 new triggers (defrost start/stop, error occurred/cleared, status changes, hybrid-mode changes, COP drops below threshold) and 6 new conditions (is active, is defrosting, has error, status is, hybrid mode is, DHW active). 7 new status sensors decoded from the bitfields (backup heater 1/2 active, DHW backup active, service required, water pressure low, cooling active, solar active). Writable COP switch-threshold (HP054) added for fine-tuning hybrid mode. Hybrid-mode labels now match the official Remeha spec (No hybrid / Cost / Efficiency / CO₂). Tariff writes are rate-limited per spec (max 6 per 24h) and all writes are clamped to safe register ranges. Support URL now points to the community forum.

Visualizza il changelog

Remeha

Remeha non è compatibile con l’Homey selezionato.

Remehaverrà installato a breve su Homey.
Installa