Warning! This app might not work properly.
This app version is currently being tested, and has not yet been reviewed. It might not work as expected.
Be extra careful when installing this app.
« Back to the regular version
Bring your Komfovent DOMEKT ventilation into Homey. Change modes, build everyday routines with Flow, and keep an eye on power use, air quality and room temperature. See the wall-panel reading alongside the active temperature target, or change a saved profile's target with Flow. Choose Mini, Compact or Advanced for your Dashboard. Everything runs over your local network, without a Komfovent cloud account.
You need Homey Pro and a compatible C6M controller with Modbus TCP enabled. Readings depend on your unit and sensors. Advanced controls and optional room-sensor automation need separate setup. Temperature targets do not force heating on; CAV control is experimental and needs checking on your unit. This is an independent community app, not an official Komfovent app.
Read more ›
Flow cards
Click on a device above to show related Flow cards only.
When...
C6/C6M ventilation unit
The power changed
C6/C6M ventilation unit
The power meter changed
C6/C6M ventilation unit
The generic alarm turned on
C6/C6M ventilation unit
The generic alarm turned off
C6/C6M ventilation unit
Active airflow target changed
C6/C6M ventilation unit
Control failed
C6/C6M ventilation unit
Actual fan level changed
C6/C6M ventilation unit
Filter remaining reached or fell below Remaining threshold % %
C6/C6M ventilation unit
Operating mode changed
C6/C6M ventilation unit
Active temperature target changed
C6/C6M ventilation unit
Ventilation unit turned off
C6/C6M ventilation unit
Ventilation unit turned on
And...
C6/C6M ventilation unit
The generic alarm is on
C6/C6M ventilation unit
Control is ready
C6/C6M ventilation unit
Fresh measurements are available
C6/C6M ventilation unit
Measured fan level Measurement is above Threshold % %
C6/C6M ventilation unit
Measured fan level Measurement is below Threshold % %
C6/C6M ventilation unit
Measured air volume Measurement is above Threshold m³/h m³/h
C6/C6M ventilation unit
Measured air volume Measurement is below Threshold m³/h m³/h
C6/C6M ventilation unit
An alarm is active
C6/C6M ventilation unit
Ventilation mode is Mode
Then...
C6/C6M ventilation unit
End the holiday period
C6/C6M ventilation unit
Report Requested mode because Reason (room and threshold)
C6/C6M ventilation unit
Set Profile CAV targets to Supply target/Extract target Unit
C6/C6M ventilation unit
Schedule holiday from Start date to End date
C6/C6M ventilation unit
Set Intensive profile to Supply target/Extract target percent
C6/C6M ventilation unit
Set Profile to Target capacity (%)% target capacity and preserve the ratio
C6/C6M ventilation unit
Set ventilation to Mode
C6/C6M ventilation unit
Set ventilation unit State
C6/C6M ventilation unit
Set Profile airflow targets to Supply target/Extract target percent
C6/C6M ventilation unit
Set reheating permission for Profile: Permission
C6/C6M ventilation unit
Set Profile temperature target to Temperature °C
What’s new
Version 1.9.1 — Adds active-target Flow triggers, on/off control and optional native holiday scheduling with an early-end card. Removes the duplicate fan-slider page while keeping saved profiles and all three widgets. Corrects an old power-trigger hint and CAV control notes; the control code is unchanged from 1.9.0. Holiday remains beta on other firmware and CAV units.
View changelog