Connect every Modbus devices

Czytaj więcej ›

Obsługiwane urządzenia

Karty Flow

Kliknij na urządzenie powyżej, aby wyświetlić tylko powiązane karty Flow.

Wtedy...

Modbus Device
Connect device
i
Connect a device if needed. The connection can be disconnected by a flow action.
Modbus Device
Disconnect device
i
Disconnect a device if needed.
Modbus Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Modbus Slave-Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.

Pomoc

Masz problem z tą aplikacją? Skontaktuj się z twórcami aplikacji za pomocą forum Homey Community.

Nowości

Wersja 0.9.3 — Added delay for auto reconnect. Added error handling for wromg IP in settings.

Zobacz listę zmian

Modbus