Let op! Deze app werkt mogelijk niet.

Deze app versie wordt op dit moment getest, en is nog niet goedgekeurd.
Let extra goed op bij het gebruiken van deze app.

« Terug naar de reguliere versie

Connect every Modbus devices

Lees meer ›

Ondersteunde apparaten

Flow-kaarten

Klik op een apparaat hierboven om gerelateerde Flow-kaarten te zien.

Dan...

Modbus Device
Connect device
i
Connect a device if needed. The connection can be disconnected by a flow action.
Modbus Device
Disconnect device
i
Disconnect a device if needed.
Modbus Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Bit # Bit number from Holding Register Register with addressing Addressing
i
Reads a Bit from a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Bit # Bit of Holding Register Register with value Value with addressing Addressing in Mode
i
Reads Bit of a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Modbus Slave-Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Bit # Bit number from Holding Register Register with addressing Addressing
i
Reads a Bit from a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Bit # Bit of Holding Register Register with value Value with addressing Addressing in Mode
i
Reads Bit of a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.

Ondersteuning

Heb je een probleem met deze app? Neem contact op met de ontwikkelaar via het Homey Community Forum.

Wat is nieuw

Versie 0.12.0 — Added device setting to prevent register writing if unchanged.

Bekijk changelog

Modbus

Modbus is niet compatibel met de geselecteerde Homey

Modbus wordt op Homey geïnstalleerd.
Installeer App