Modbus

Connect every Modbus devices

Advarsel! Denne appen fungerer kanskje ikke som den skal.

Denne appen er under testing, og har aldri blitt anmeldt. Den fungerer kanskje ikke som forventet.
Vær ekstra forsiktig når du installerer denne appen.

« Tilbake til standardversjonen

Connect every Modbus devices

Les mer ›

Støttede enheter

Flow-kort

Klikk på en enhet ovenfor for å kun vise relaterte Flow-kort.

Så …

Modbus Device
Connect device
i
Connect a device if needed. The connection can be disconnected by a flow action.
Modbus Device
Disconnect device
i
Disconnect a device if needed.
Modbus Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Bit # Bit number from Holding Register Register with addressing Addressing
i
Reads a Bit from a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Bit # Bit of Holding Register Register with value Value with addressing Addressing in Mode
i
Reads Bit of a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Modbus Slave-Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Bit # Bit number from Holding Register Register with addressing Addressing
i
Reads a Bit from a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Bit # Bit of Holding Register Register with value Value with addressing Addressing in Mode
i
Reads Bit of a Modbus register. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.

Støtte

Har du et problem med denne appen? Kontakt utvikleren via Homey-fellesskapsforum.

Nyheter

Versjon 0.12.0 — Added device setting to prevent register writing if unchanged.

Vis endringslogg

Modbus

Modbus er ikke kompatibel med den valgte Homey.

Modbus vil straks installeres på Homey.
Installer