Fronius GEN24 Modbus Control

Smarter Fronius GEN24 control over Modbus TCP.
Smarter Fronius GEN24 control over Modbus TCP.

Lire plus ›

Appareils pris en charge

Cartes Flow

Cliquez sur un appareil ci-dessus pour afficher uniquement les cartes Flow associées.

Quand...

Fronius GEN24
L'énergie a changé

Alors...

Fronius GEN24
Allow export (disable inverter limit)
i
Enables Modbus override: ramp=0, WMaxLimPct=100%, WMaxLim_Ena=1.
Fronius GEN24
Use inverter export limit
i
Disables Modbus override (WMaxLim_Ena=0) so the inverter's Grid Regulations/export limit setting controls export.
Fronius GEN24
Force discharge Discharge power (W) W
i
Forces battery discharge by writing negative rate. Uses device capacity/max kW + scale. Sets StorCtl_Mod=2.
Fronius GEN24
Reset battery control
i
Stops external control: zeros charge/discharge limits and sets StorCtl_Mod=0.
Fronius GEN24
Set charge power to Charge power (W) W
i
Uses device settings (max kW + scale, default -2) to write charge limit. StorCtl_Mod is set to charge.
Fronius GEN24
Set max discharge power to Discharge power (W) W
i
Sets battery max discharge limit (OutWRte). Uses device settings (capacity/max kW + scale). StorCtl_Mod is set to discharge.
Fronius GEN24
Limit inverter production to Max production (W) W
i
Caps total inverter production (feed-in limit) to this W target, regardless of house load.
Fronius GEN24
Charge up to Max charge (W) W without exceeding Max grid import (W) W import or Main fuse per phase (A, optional) A/phase (check every Check interval (s, min 30) s)
Fronius GEN24
Keep import under Peak target (W) W (duration Duration (minutes, 0 = until stopped) min, interval Update interval (seconds) s)
i
Discharge to keep import below the peak target. Runs periodically until duration expires or stopped.
Fronius GEN24
Limit inverter production to Max production (W) W
Fronius GEN24
Auto zero export (interval Update interval (seconds) s, duration Duration (minutes, 0 = until stopped) min)
i
Adjusts feed-in limit to keep export near 0 W using Smart Meter. Runs periodically until stopped or duration expires.
Fronius GEN24
Stop import-limited charging
Fronius GEN24
Stop peak shaving
Fronius GEN24
Remove production limit (restore 100%)
Fronius GEN24
Stop auto zero export

Assistance

Le développeur de cette appli ne propose pas d’assistance directe.

Nouveautés

Version 1.3.18 — Icon structure fix: copied exact SVG structure (DOCTYPE, version, preserveAspectRatio, g transform) from certified Kvartspris app.

Afficher le journal des modifications

Fronius GEN24 Modbus Control

Fronius GEN24 Modbus Control n’est pas compatible avec le Homey sélectionné.

Fronius GEN24 Modbus Control va s’installer sur Homey dans un instant.
Installer