Toshiba Estia

Control heating, cooling and hot water for your Toshiba Estia heat pump.
Control heating, cooling and hot water for your Toshiba Estia heat pump.

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

Estia Heat Pump
Turned on
Estia Heat Pump
Turned off
Estia Heat Pump
The thermostat mode changed to ...
Estia Heat Pump
The target temperature changed
Estia Heat Pump
The temperature changes
Estia Heat Pump
The generic alarm turned on
Estia Heat Pump
The generic alarm turned off
Estia Heat Pump
The power changed
Estia Heat Pump
The power meter changed
Estia Heat Pump
Heat pump faulted
i
Fires once when the heat pump's alarm flag transitions from inactive to active. Tokens carry the fault code and origin so you can branch logic.
Estia Heat Pump
The season changed
i
Use it with the "Season is" condition to switch between heating and cooling.

And...

Estia Heat Pump
Is turned on
Estia Heat Pump
The thermostat mode is ...
Estia Heat Pump
The generic alarm is on
Estia Heat Pump
Heat pump alarm is active
Estia Heat Pump
Hot water is on
Estia Heat Pump
Season is ...

Then...

Estia Heat Pump
Turn on
Estia Heat Pump
Turn off
Estia Heat Pump
Toggle on or off
Estia Heat Pump
Set the thermostat mode to ...
Estia Heat Pump
Set the temperature °C
Estia Heat Pump
Turn auto temperature ...
i
Auto temperature (the "A" mode) lets the heat pump pick the water temperature from the outdoor temperature.
Estia Heat Pump
Boost DHW for Minutes minutes
i
Turns DHW boost on immediately, then off after the specified number of minutes. Requires a DHW tank (device setting).
Estia Heat Pump
Turn hot water ...
i
Switches hot water (DHW) operation on or off, as on the remote controller.
Estia Heat Pump
Set the season to ...
i
With automatic season detection on, the app changes the season again as soon as the average outdoor temperature is past one of its switch points.
Estia Heat Pump
SG Ready Forced ON is ...
i
Use this when a Flow switches the SG Ready contacts (I/P7 + I/P8 closed = System Forced ON). The app can't read the contacts; knowing about the boost lets it count the backup heater, which Forced ON switches on at once (DN 6CE = 0).
Estia Heat Pump
Set water temperature to Temperature °C
i
Sets the Zone 1 setpoint (the water temperature for the floor). Has no effect while auto temperature is on — turn that off first.

Support

Having an issue with this app? Contact the developer via the developer website.

What’s new

Version 1.2.1 — Much better power and energy estimate. On R32 units the app now follows the compressor's own frequency and refrigerant temperatures, checked against a power meter, including the unit's own use (standby, pump and fan). Calibrate it once by typing the CT current from the remote controller in the settings. Other units use the water temperatures, with the water flow learnt from hot-water heat-ups. Hot-water runs are no longer mistaken for cooling and the backup heater is recognised. Also new: flow cards to turn hot water on or off and to check whether it's on. The estimate is now flagged as calculated, not measured; if a separate meter already measures the heat pump, exclude this device from Homey Energy. Also new since 1.0.27: season detection (summer, mid-season, winter) from the average outdoor temperature, with flow cards to switch between heating and cooling.