Marstek Homebatteries - Complete Energy Storage Management
Transform your home into a smart energy powerhouse! This Homey app brings full control of your energy storage system directly to your fingertips, enabling intelligent automation and optimal energy management like never before.
Unlock Your Energy Independence
Take complete control of your home's energy storage with sophisticated automation capabilities that adapt to your lifestyle and energy needs. Whether you want to maximize solar self-consumption, take advantage of dynamic energy pricing, or ensure backup power during outages - this app makes it all possible!
Läs mer ›
Flow-kort
Klicka på en enhet ovan för att visa endast relaterade Flow-kort.
När...
Venus D
Spänningen ändrades
Venus D
Den elektriska strömmen ändrades
Venus D
Strömmen ändrades
Venus D
Temperaturen ändrades
Venus D
Batteriets laddningsstatus har ändrats ...
Venus D
Det generiska larmet är aktiverat
Venus D
Det generiska larmet är inaktiverat
Venus D
Batterinivån ändrades
Venus D
Måleffekten ändrades
Venus D
Måleffektläget ändrades till ...
Venus D
Charging status changed
Venus D
Battery started charging
Venus D
Battery started discharging
Venus D
Battery level dropped below threshold
Venus D
Battery level rose above threshold
Venus D
Battery temperature too high
Venus D
Battery temperature too low
Venus D
Battery backup mode changed to Mode
Venus D
Force charge mode changed to Mode
Venus D
Operation mode changed to Mode
Venus D
Force charge power changed to Power (W) W
Venus D
Force discharge power changed to Power (W) W
Venus D
Force SOC target changed to SOC Target (%)%
Venus D
Battery fault detected
Venus D
Battery warning detected
Venus D
Grid fault detected
Venus D
Battery system fault detected
Venus E
Spänningen ändrades
Venus E
Den elektriska strömmen ändrades
Venus E
Strömmen ändrades
Venus E
Det generiska larmet är aktiverat
Venus E
Det generiska larmet är inaktiverat
Venus E
Temperaturen ändrades
Venus E
Batteriets laddningsstatus har ändrats ...
Venus E
Batterinivån ändrades
Venus E
Måleffekten ändrades
Venus E
Måleffektläget ändrades till ...
Venus E
Charging status changed
Venus E
Battery started charging
Venus E
Battery started discharging
Venus E
Battery level dropped below threshold
Venus E
Battery level rose above threshold
Venus E
Battery fault detected
Venus E
Battery warning detected
Venus E
Grid fault detected
Venus E
Battery system fault detected
Venus E
Hardware fault detected
Venus E
System fault detected
Venus E
Battery temperature too high
Venus E
Battery temperature too low
Venus E
Battery backup mode changed to Mode
Venus E
Force charge mode changed to Mode
Venus E
Operation mode changed to Mode
Venus E
Force charge power changed to Power (W) W
Venus E
Force discharge power changed to Power (W) W
Venus E
Force SOC target changed to SOC Target (%)%
Och...
Venus D
Batteriets laddningsstatus är ...
Venus D
Det generiska larmet är på
Venus D
Måleffektläget är ...
Venus D
Battery backup mode is Mode
Venus D
Force charge mode is Mode
Venus D
Operation mode is Mode
Venus D
Force charge power is greater than Power (W) W
Venus D
Force discharge power is greater than Power (W) W
Venus D
Force SOC target is greater than SOC Target (%)%
Venus D
Battery is charging
Venus D
Battery is discharging
Venus D
Battery level is above Percentage (%)%
Venus D
Battery level is below Percentage (%)%
Venus D
Temperature is above Temperature (°C)°C
Venus D
Max charge power limit is below Power (W) W
Venus D
Max discharge power limit is below Power (W) W
Venus D
Charging cutoff SOC is above Percentage (%)%
Venus D
Discharging cutoff SOC (reserve) is above Percentage (%)%
Venus D
Battery has a fault
Venus E
Det generiska larmet är på
Venus E
Batteriets laddningsstatus är ...
Venus E
Måleffektläget är ...
Venus E
Battery backup mode is Mode
Venus E
Force charge mode is Mode
Venus E
Operation mode is Mode
Venus E
Force charge power is greater than Power (W) W
Venus E
Force discharge power is greater than Power (W) W
Venus E
Force SOC target is greater than SOC Target (%)%
Venus E
Battery is charging
Venus E
Battery is discharging
Venus E
Battery level is above Percentage (%)%
Venus E
Battery level is below Percentage (%)%
Venus E
Battery has a fault
Venus E
Temperature is above Temperature (°C)°C
Venus E
Max charge power limit is below Power (W) W
Venus E
Max discharge power limit is below Power (W) W
Venus E
Charging cutoff SOC is above Percentage (%)%
Venus E
Discharging cutoff SOC (reserve) is above Percentage (%)%
Då...
Venus D
Ställ in måleffekten W
Venus D
Ställ in måleffektläget på ...
Venus D
Set battery backup mode to Mode
Venus D
Set force SOC target to SOC Target (%)%
Venus D
Set charging cutoff SOC to Percentage (%)%
Venus D
Set discharging cutoff SOC to Percentage (%)%
Venus E
Ställ in måleffekten W
Venus E
Ställ in måleffektläget på ...
Venus E
Set battery backup mode to Mode
Venus E
Set force SOC target to SOC Target (%)%
Venus E
Set charging cutoff SOC to Percentage (%)%
Venus E
Set discharging cutoff SOC to Percentage (%)%
Support
Har du problem med den här appen?
Kontakta utvecklaren här.
Vad är nytt?
Version 1.5.10 — Venus D: measure_power.battery is now available as a derived value. Native register 32102 returns garbage on Venus D hardware even on the working v147 firmware, so the driver skipped it entirely and users had no battery-power tile at all where Venus E users have one out of the box. Now reconstructed as MPPT_sum + (-measure_power) - solar in plus net AC contribution equals what the battery is receiving. Same charging-positive sign convention Venus E uses. Cap picks up automatically on existing devices via repairCapabilities.
Visa ändringslogg