Delta Dore Tydom

Native, local Tydom heating in your Homey flows.
Native, local Tydom heating in your Homey flows.

Läs mer ›

Enheter som stöds

Flow-kort

Klicka på en enhet ovan för att visa endast relaterade Flow-kort.

När...

Thermostat
Temperaturen ändrades
Thermostat
Måltemperaturen ändrades
Thermostat
Termostatläge ändrades ...
Thermostat
Aktiverad
Thermostat
Inaktiverad
Thermostat
Batterialarmet aktiverat
Thermostat
Batterialarmet aktiverat
Thermostat
Setpoint reached — within Tolerance°C tolerance
i
MODE-AWARE. Fires when the room temperature has hit or passed the setpoint, within [tolerance]°C margin. • In HEATING mode: fires when the room has warmed up to at least (setpoint − tolerance). • In COOLING mode: fires when the room has cooled down to at most (setpoint + tolerance). • In AUTO / OFF: does NOT fire (unclear which direction is 'reached'). Typical use: trigger 'Turn boost off' once the target is reached, regardless of season. Set tolerance to 0 for exact match, or e.g. 0.2°C to end boost slightly before hitting setpoint.
Thermostat
Cannot reach setpoint — off by at least Shortfall°C in the wrong direction
i
MODE-AWARE. Fires when the room temperature is at least [delta]°C off the setpoint in the direction the HVAC is failing. • In HEATING mode: fires when the room is colder than (setpoint − delta). • In COOLING mode: fires when the room is warmer than (setpoint + delta). • In AUTO / OFF: does NOT fire (unclear which direction is 'wrong'). Typical use: trigger 'Turn boost on' when the HVAC is falling behind, regardless of season.
Thermostat
Temperature is at least Delta°C above setpoint
i
Fires when the measured room temperature rises at or above (setpoint + delta). Evaluated on every temperature or setpoint update the thermostat reports.
Thermostat
Temperature is at least Delta°C below setpoint
i
Fires when the measured room temperature falls at or below (setpoint − delta). Evaluated on every temperature or setpoint update the thermostat reports.

Och...

Thermostat
Termostatläge är ...
Thermostat
Är på
Thermostat
Batterialarmet är på

Då...

Thermostat
Ställ in temperaturen °C
Thermostat
Ställ in läget ...
Thermostat
Aktivera
Thermostat
Stäng av
Thermostat
Växla på och av
Thermostat
Turn boost off
i
Cancels the thermostat boost (clears the setpoint derogation) so the normal schedule / setpoint resumes.
Thermostat
Turn boost on
i
Forces the thermostat to run at max (setpoint 30°C for heating, 10°C for cooling) until boost is turned off. Uses the Tydom setpoint-derogation mechanism.
Thermostat
Turn boost on for Duration (minutes) minute(s)
i
Forces the thermostat to max (30°C heating / 10°C cooling) for a specific duration, then auto-cancels. The Tydom gateway owns the countdown — if power cycles or the app restarts, boost continues until the timer elapses.

Support

Har du problem med den här appen? Kontakta utvecklaren här.

Vad är nytt?

Version 1.0.3 — Rewritten README that better explains what the app does and why it is useful in Homey flows.

Visa ändringslogg

Delta Dore Tydom

Delta Dore Tydom är inte kompatibelt med vald Homey.

Delta Dore Tydom installeras på Homey inom kort.
Installera