Delta Dore Tydom

Native, local Tydom heating in your Homey flows.
Native, local Tydom heating in your Homey flows.

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Thermostat
La temperatura è cambiata
Thermostat
La temperatura nominale è cambiata
Thermostat
La modalità del termostato è cambiata ...
Thermostat
Attivato
Thermostat
Disattivato
Thermostat
L'allarme della batteria è stato attivato
Thermostat
L'allarme della batteria è stato disattivato
Thermostat
Setpoint reached — within Tolerance°C tolerance
i
MODE-AWARE. Fires when the room temperature has hit or passed the setpoint, within [tolerance]°C margin. • In HEATING mode: fires when the room has warmed up to at least (setpoint − tolerance). • In COOLING mode: fires when the room has cooled down to at most (setpoint + tolerance). • In AUTO / OFF: does NOT fire (unclear which direction is 'reached'). Typical use: trigger 'Turn boost off' once the target is reached, regardless of season. Set tolerance to 0 for exact match, or e.g. 0.2°C to end boost slightly before hitting setpoint.
Thermostat
Cannot reach setpoint — off by at least Shortfall°C in the wrong direction
i
MODE-AWARE. Fires when the room temperature is at least [delta]°C off the setpoint in the direction the HVAC is failing. • In HEATING mode: fires when the room is colder than (setpoint − delta). • In COOLING mode: fires when the room is warmer than (setpoint + delta). • In AUTO / OFF: does NOT fire (unclear which direction is 'wrong'). Typical use: trigger 'Turn boost on' when the HVAC is falling behind, regardless of season.
Thermostat
Temperature is at least Delta°C above setpoint
i
Fires when the measured room temperature rises at or above (setpoint + delta). Evaluated on every temperature or setpoint update the thermostat reports.
Thermostat
Temperature is at least Delta°C below setpoint
i
Fires when the measured room temperature falls at or below (setpoint − delta). Evaluated on every temperature or setpoint update the thermostat reports.

E...

Thermostat
La modalità del termostato è ...
Thermostat
È attivato
Thermostat
L'allarme della batteria è acceso

Poi...

Thermostat
Imposta la temperatura °C
Thermostat
Imposta la modalità ...
Thermostat
Attiva
Thermostat
Disattiva
Thermostat
Attiva o disattiva
Thermostat
Turn boost off
i
Cancels the thermostat boost (clears the setpoint derogation) so the normal schedule / setpoint resumes.
Thermostat
Turn boost on
i
Forces the thermostat to run at max (setpoint 30°C for heating, 10°C for cooling) until boost is turned off. Uses the Tydom setpoint-derogation mechanism.
Thermostat
Turn boost on for Duration (minutes) minute(s)
i
Forces the thermostat to max (30°C heating / 10°C cooling) for a specific duration, then auto-cancels. The Tydom gateway owns the countdown — if power cycles or the app restarts, boost continues until the timer elapses.

Supporto

Hai un problema con questa app? Contatta lo sviluppatore qui.

Novità

Versione 1.0.3 — Rewritten README that better explains what the app does and why it is useful in Homey flows.

Visualizza il changelog

Delta Dore Tydom

Delta Dore Tydom non è compatibile con l’Homey selezionato.

Delta Dore Tydomverrà installato a breve su Homey.
Installa