Fronius GEN24 Modbus Control

Smarter Fronius GEN24 control over Modbus TCP.
Smarter Fronius GEN24 control over Modbus TCP.

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Fronius GEN24
L'energia è cambiata

Poi...

Fronius GEN24
Allow export (disable inverter limit)
i
Enables Modbus override: ramp=0, WMaxLimPct=100%, WMaxLim_Ena=1.
Fronius GEN24
Use inverter export limit
i
Disables Modbus override (WMaxLim_Ena=0) so the inverter's Grid Regulations/export limit setting controls export.
Fronius GEN24
Force discharge Discharge power (W) W
i
Forces battery discharge by writing negative rate. Uses device capacity/max kW + scale. Sets StorCtl_Mod=2.
Fronius GEN24
Reset battery control
i
Stops external control: zeros charge/discharge limits and sets StorCtl_Mod=0.
Fronius GEN24
Set charge power to Charge power (W) W
i
Uses device settings (max kW + scale, default -2) to write charge limit. StorCtl_Mod is set to charge.
Fronius GEN24
Set max discharge power to Discharge power (W) W
i
Sets battery max discharge limit (OutWRte). Uses device settings (capacity/max kW + scale). StorCtl_Mod is set to discharge.
Fronius GEN24
Limit inverter production to Max production (W) W
i
Caps total inverter production (feed-in limit) to this W target, regardless of house load.
Fronius GEN24
Charge up to Max charge (W) W without exceeding Max grid import (W) W import or Main fuse per phase (A, optional) A/phase (check every Check interval (s, min 30) s)
Fronius GEN24
Keep import under Peak target (W) W (duration Duration (minutes, 0 = until stopped) min, interval Update interval (seconds) s)
i
Discharge to keep import below the peak target. Runs periodically until duration expires or stopped.
Fronius GEN24
Limit inverter production to Max production (W) W
Fronius GEN24
Auto zero export (interval Update interval (seconds) s, duration Duration (minutes, 0 = until stopped) min)
i
Adjusts feed-in limit to keep export near 0 W using Smart Meter. Runs periodically until stopped or duration expires.
Fronius GEN24
Stop import-limited charging
Fronius GEN24
Stop peak shaving
Fronius GEN24
Remove production limit (restore 100%)
Fronius GEN24
Stop auto zero export

Supporto

Lo sviluppatore di questa app non offre un supporto diretto.

Novità

Versione 1.3.18 — Icon structure fix: copied exact SVG structure (DOCTYPE, version, preserveAspectRatio, g transform) from certified Kvartspris app.

Visualizza il changelog

Fronius GEN24 Modbus Control

Fronius GEN24 Modbus Control non è compatibile con l’Homey selezionato.

Fronius GEN24 Modbus Controlverrà installato a breve su Homey.
Installa