Dantherm HCV

Fresh air on autopilot — and free cooling all summer, in every Flow
Fresh air on autopilot — and free cooling all summer, in every Flow

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Dantherm HCV
Attivato
Dantherm HCV
Disattivato
Dantherm HCV
L'umidità è cambiata
Dantherm HCV
L'energia è cambiata
Dantherm HCV
L'allarme generico è stato attivato
Dantherm HCV
L'allarme generico è stato disattivato
Dantherm HCV
Bypass damper changed
Dantherm HCV
An alarm occurred
Dantherm HCV
Filter needs replacement
Dantherm HCV
Operating mode changed
Dantherm HCV
Fan level changed
Dantherm HCV
Free cooling started
i
The app has run the fans up to pull cool outside air in.
Dantherm HCV
Free cooling stopped
i
The fan level has been handed back — either the house reached the setpoint or the cooling was no longer worth having.

E...

Dantherm HCV
È attivato
Dantherm HCV
L'allarme generico è acceso
Dantherm HCV
Operating mode is ...
Dantherm HCV
Bypass is open
Dantherm HCV
Fan level is ...
Dantherm HCV
Filter days remaining is below 14
Dantherm HCV
Free cooling is running

Poi...

Dantherm HCV
Attiva
Dantherm HCV
Disattiva
Dantherm HCV
Attiva o disattiva
Dantherm HCV
Set operating mode to ...
Dantherm HCV
Set fan level to ...
Dantherm HCV
... manual bypass
Dantherm HCV
Reset filter timer
Dantherm HCV
Reset alarm
Dantherm HCV
Turn away mode ...
Dantherm HCV
Turn night mode ...
Dantherm HCV
Select week program 1
Dantherm HCV
Set ... bypass to open between 12 and 24 °C
i
Overrides the free cooling thresholds, so a Flow can widen them on a hot day and narrow them again afterwards.
Dantherm HCV
Cool down to 21 °C
i
Lets a Flow hold a different temperature when nobody is home, or overnight.
Dantherm HCV
Hand the unit to ...
i
Normal operation gives the fan level and operating mode straight back and releases a manual bypass.

Widget

Puoi aggiungere i widget di questa app alla dashboard oppure alla schermata iniziale nell’app mobile.

Ventilation status
Ventilation status
Ventilation compact
Ventilation compact

Supporto

Hai un problema con questa app? Contatta lo sviluppatore inviando un’email.

Novità

Versione 1.1.0 — First release. Reads temperatures, humidity, fan speeds, bypass position and filter life from Dantherm HCV, HCC, RCV and WG units over Modbus TCP, and sets operating mode, fan level and bypass from Flows. Two dashboard widgets show the heat exchanger at work. Smarter cooling through the summer: say how cool you want the house, hand control to Homey, and the app runs the fans up while there is free cooling worth having outside, handing the level and operating mode straight back on arrival. Two plain questions replace the controller's four bypass thresholds. And when it is warmer outside than in — a hot afternoon, or a heat pump cooling the house — the bypass shuts and the exchanger runs the other way, so ventilating costs far less of the cooling you have paid for. Copy the six figures from your commissioning report and it also estimates airflow, power draw and recovered heat, working out the commissioned negative pressure from the exchanger itself. The capability set adapts to what each unit is actually fitted with, and the unit is found again automatically if its IP address changes.

Visualizza il changelog

Dantherm HCV

Dantherm HCV non è compatibile con l’Homey selezionato.

Dantherm HCVverrà installato a breve su Homey.
Installa