SNMP - Network Devices

UPS, NAS and network switches over SNMP — including a UPS plugged into your NAS

Attenzione! Questa app potrebbe non funzionare correttamente.

Questa app è in fase di test e non è mai stata recensita. Potrebbe non funzionare come previsto.
Fai molta attenzione quando installi questa app.

« Torna alla versione normale

UPS, NAS and network switches over SNMP — including a UPS plugged into your NAS

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

NAS or host
A volume fills above Percent %
i
Fires once, at the moment a volume crosses the threshold upwards — not on every reading while it stays above. One card covers every volume: which one crossed comes back as a token, because Homey generates no Flow card of its own for a per-volume sub-capability.
NAS or host
The host reboots
i
Fires when the host's uptime goes backwards, which means it restarted between two readings. One caveat, said plainly: the host counts uptime in a 32-bit counter that wraps after about 497 days, and a wrap is indistinguishable from a reboot.
Switch port
The link comes up
i
Something was plugged in, or came back. Fires on the change, not on the state — a port that stays up does not fire again.
Switch port
The link goes down
i
The cable was unplugged, or the device at the other end went off. A poll that gets no answer does NOT fire this card — an unreachable switch makes the device unavailable instead, so a dropped SNMP packet never looks like an unplugged cable.
Switch port
The link state becomes State
Switch port
The PoE socket reports a fault
i
The switch says it cannot power this port — a short, an overload, or a device drawing more than its class. Only fires on switches whose PoE sockets the app could match to a port reliably.
UPS
The UPS switches to battery
i
Fires within about ten seconds of a power cut. This is the card to use for shutting non-essential devices down.
UPS
Mains power comes back
i
Only fires when the UPS itself says it is back on mains. If the UPS is relayed by a NAS that the outage switched off, the app cannot see the end of the outage — see the app description.
UPS
Contact is lost while on battery
i
A NAS that relays the UPS is itself powered by it, and switches off partway through the outage. This card says the outage lasted long enough for that to happen — the reported status stays on "battery" rather than pretending the power is back.
UPS
The battery becomes low
i
Uses the UPS's own low-battery flag, which follows the thresholds configured on the UPS — not a percentage guessed by the app.
UPS
Runtime drops below Minutes minutes
i
Fires on the crossing, once per outage, not on every reading below the threshold. Each Flow can use its own number of minutes.
UPS
The UPS is overloaded
i
Too much is plugged into the UPS. Fires once when the alarm appears, not on every reading.
UPS
The battery needs replacing
i
Fires once when the UPS raises the flag. A worn battery stays flagged for weeks, so this is not repeated on every reading.
UPS
The status changes to Status

E...

NAS or host
A volume is above Percent %
i
True when the fullest volume is above the threshold. Answers false when no volume could be read: a measurement that was not taken is not free space, and this card is there to guard a backup.
NAS or host
CPU load is above Percent %
i
The average over every core the host reports, not the first one. Answers false when the load could not be read.
NAS or host
Memory used is above Percent %
i
Careful with a low threshold: on Linux the figure counts cache and buffers as used, so a perfectly healthy NAS sits at 80–95 %. Answers false when memory could not be read.
Switch port
The link is up
Switch port
The PoE socket is delivering power
i
False when the app could not match a PoE socket to this port — it does not claim to know.
Switch port
The negotiated speed is above Speed Mbit/s
i
Answers false when the speed is unknown. A value that was not read is not a fast link, and it is not a slow one either.
UPS
The UPS is on battery
UPS
Runtime is above Minutes minutes
i
False when the runtime is unknown: an unread value is not a comfortable margin.
UPS
Battery is above Percent %
i
False when the charge is unknown, for the same reason.

Poi...

NAS or host
Read the host now
i
Takes the fast reading — load, memory, uptime — outside the normal schedule. Read-only, like everything this app does to a host: nothing here can switch anything off.
Switch port
Read this port now
Switch port
Switch the port State
i
Writes ifAdminStatus on the switch. Refuses, with a message saying what to enable, unless "Allow switching this port" is ticked in the device settings — read the warning there first: switching off the port that feeds your Homey or your router leaves no way back except physical access.
Switch port
Switch PoE power on this port State
i
Writes pethPsePortAdminEnable. Cuts the power to what is plugged in without disabling the port itself — this is the card for power-cycling a camera or an access point. Same guard as above: it refuses unless port control is enabled, and it refuses when the app could not match a PoE socket to this port rather than aiming at a guess.
UPS
Read the UPS now
i
Reads the fast group outside the schedule. The app never writes to the UPS: switching it off or starting a battery test would cut power to everything plugged into it, this Homey included.

Supporto

Hai un problema con questa app? Contatta lo sviluppatore qui.

Novità

Versione 1.0.8 — A PoE socket could be matched to the wrong port, so switching it off would have cut power to a different device. The MIB does not say which port a socket belongs to, so the app now waits for proof — a socket drawing power must sit on a port whose link is up — and offers no PoE control until it has it. Also: the network sweep can no longer start twice at once, a NAS can no longer add an unbounded number of volumes, and the stored SNMP community is no longer shown in clear when repairing a device.

Visualizza il changelog

SNMP - Network Devices

SNMP - Network Devices non è compatibile con l’Homey selezionato.

SNMP - Network Devicesverrà installato a breve su Homey.
Installa