Delta Dore Tydom

Native, local Tydom heating in your Homey flows.
Native, local Tydom heating in your Homey flows.

Leer más ›

Dispositivos compatibles

Tarjetas Flow

Haz clic en el dispositivo de arriba para mostrar solo las tarjetas Flow relacionadas.

Cuando...

Thermostat
La temperatura ha cambiado
Thermostat
La temperatura deseada ha cambiado
Thermostat
El modo del termostato ha cambiado ...
Thermostat
Encendido
Thermostat
Apagado
Thermostat
La alarma de la batería se ha activado
Thermostat
La alarma de la batería se ha desactivado
Thermostat
Setpoint reached — within Tolerance°C tolerance
i
MODE-AWARE. Fires when the room temperature has hit or passed the setpoint, within [tolerance]°C margin. • In HEATING mode: fires when the room has warmed up to at least (setpoint − tolerance). • In COOLING mode: fires when the room has cooled down to at most (setpoint + tolerance). • In AUTO / OFF: does NOT fire (unclear which direction is 'reached'). Typical use: trigger 'Turn boost off' once the target is reached, regardless of season. Set tolerance to 0 for exact match, or e.g. 0.2°C to end boost slightly before hitting setpoint.
Thermostat
Cannot reach setpoint — off by at least Shortfall°C in the wrong direction
i
MODE-AWARE. Fires when the room temperature is at least [delta]°C off the setpoint in the direction the HVAC is failing. • In HEATING mode: fires when the room is colder than (setpoint − delta). • In COOLING mode: fires when the room is warmer than (setpoint + delta). • In AUTO / OFF: does NOT fire (unclear which direction is 'wrong'). Typical use: trigger 'Turn boost on' when the HVAC is falling behind, regardless of season.
Thermostat
Temperature is at least Delta°C above setpoint
i
Fires when the measured room temperature rises at or above (setpoint + delta). Evaluated on every temperature or setpoint update the thermostat reports.
Thermostat
Temperature is at least Delta°C below setpoint
i
Fires when the measured room temperature falls at or below (setpoint − delta). Evaluated on every temperature or setpoint update the thermostat reports.

Y...

Thermostat
El modo del termostato está ...
Thermostat
Está encendido
Thermostat
La alarma de la batería está activada

Entonces...

Thermostat
Ajustar la temperatura °C
Thermostat
Configurar el modo ...
Thermostat
Encender
Thermostat
Apagar
Thermostat
Encender o apagar
Thermostat
Turn boost off
i
Cancels the thermostat boost (clears the setpoint derogation) so the normal schedule / setpoint resumes.
Thermostat
Turn boost on
i
Forces the thermostat to run at max (setpoint 30°C for heating, 10°C for cooling) until boost is turned off. Uses the Tydom setpoint-derogation mechanism.
Thermostat
Turn boost on for Duration (minutes) minute(s)
i
Forces the thermostat to max (30°C heating / 10°C cooling) for a specific duration, then auto-cancels. The Tydom gateway owns the countdown — if power cycles or the app restarts, boost continues until the timer elapses.

Asistencia

¿Tienes algún problema con esta aplicación? Contacta con el desarrollador aquí.

Novedades

Versión 1.0.3 — Rewritten README that better explains what the app does and why it is useful in Homey flows.

Ver registro de cambios

Delta Dore Tydom

Delta Dore Tydom no es compatible con el Homey seleccionado.

Delta Dore Tydom se instalará en Homey en breve.
Instalar