Modbus

Connect every Modbus devices
Connect every Modbus devices

Læs mere ›

Understøttede enheder

Flow-kort

Klik på en enhed ovenfor for kun at vise relaterede Flow-kort.

Så...

Modbus Device
Connect device
i
Connect a device if needed. The connection can be disconnected by a flow action.
Modbus Device
Disconnect device
i
Disconnect a device if needed.
Modbus Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Modbus Slave-Device
Read Holding Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Coil Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Discrete Input Register Register with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Read Input Register Register with size Size for type STRING or BYTE of type Type with addressing Addressing
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Holding Register Register with value Value of type Type with addressing Addressing in Mode
i
Reads a Modbus register from a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.
Advanced
Modbus Slave-Device
Write Coil Register Register with value Value with addressing Addressing in Mode
i
Writes a Coil-Modbus register of a Modbus device. Depending on the manufacturer documentation, register values (starting with #1) or address values (starting with #0) can be used. Choose the appropriate addressing.

Support

Har du et problem med denne app? Kontakt udvikleren via Homey community forum.

Hvad er nyt

Version 0.9.3 — Added delay for auto reconnect. Added error handling for wromg IP in settings.

Se ændringslog