Aikion Controller
Run mode changed
Aikion Controller
Device compliance error
Aikion Controller
Grid congestion limit reached
Aikion Controller
Cloud connection status changed
i
Triggered when the controller connects to or disconnects from the Aikion cloud (realtime server). The 'Connected' token is true when connected, false when disconnected.
Aikion Controller
Write to device failed
i
Triggered when Aikion exhausts retries trying to write a value to a connected inverter or charger. The same trigger is rate-limited to once every 30 minutes per device + register.
Charger Box - GLBDC
Den elektriska strømmen ble endret
Charger Box - GLBDC
Strømmåleren ble endret
Charger Box - GLBDC
Strømmen ble endret
Charger Box - GLBDC
Temperaturen endres
Charger Box - GLBDC
Startet lading
Charger Box - GLBDC
Stoppet lading
Charger Box - GLBDC
Elbilladerens ladestatus ble endret ...
Charger Box - GLBDC
Charger status changed
Charger Box - GLBDC
Availability mode changed
Charger Box - GLBDC
Current limit changed
Charger Box - GLBDC
Charging power changed
Charger Box - GLBDC
L1 charge current changed
Charger Box - GLBDC
L2 charge current changed
Charger Box - GLBDC
L3 charge current changed
Charger Box - GLBDC
Charged this session changed
Deye Battery
Batterinivået ble endret
Deye Battery
Spenningen ble endret
Deye Battery
Den elektriska strømmen ble endret
Deye Battery
Strømmen ble endret
Deye Battery
Temperaturen endres
Deye Battery
Battery power changed
i
Triggered when the battery power changes. Positive = charging, negative = discharging.
Deye Battery
Battery SoC changed
i
Triggered when the battery state of charge changes
Deye High Voltage Hybrid 3Phase
Strømmen ble endret
Deye High Voltage Hybrid 3Phase
Strømmåleren ble endret
Deye High Voltage Hybrid 3Phase
Export limit changed
i
Triggered when the grid export limit changes
Deye High Voltage Hybrid 3Phase
Solar power changed
i
Triggered when the solar power changes
Deye Low Voltage Hybrid 3Phase
Strømmen ble endret
Deye Low Voltage Hybrid 3Phase
Strømmåleren ble endret
Deye Low Voltage Hybrid 3Phase
Export limit changed
i
Triggered when the grid export limit changes
Deye Low Voltage Hybrid 3Phase
Solar power changed
i
Triggered when the solar power changes
Deye Smart Meter
Strømmen ble endret
Deye Smart Meter
Frekvensen ble endret
Deye Smart Meter
Grid power changed
i
Triggered when the grid power changes. Positive = importing, negative = exporting.
Deye Smart Meter
Load power changed
i
Triggered when the load power changes
Fronius Battery
Spenningen ble endret
Fronius Battery
Strømmen ble endret
Fronius Battery
Batterinivået ble endret
Fronius Battery
Batteriladestatusen ble endret ...
Fronius GEN24 Hybrid Inverter
Strømmen ble endret
Fronius Smart Meter
Frekvensen ble endret
Fronius Smart Meter
Strømmen ble endret
GoodWe Battery
Batterinivået ble endret
GoodWe Battery
Temperaturen endres
GoodWe Battery
Spenningen ble endret
GoodWe Battery
Den elektriska strømmen ble endret
GoodWe Battery
Strømmen ble endret
GoodWe Battery
Batteriladestatusen ble endret ...
GoodWe ET Hybrid Inverter
Strømmen ble endret
GoodWe ET Hybrid Inverter
Strømmåleren ble endret
GoodWe Smart Meter
Strømmen ble endret
GoodWe Smart Meter
Frekvensen ble endret
Gotion ESC-R125-261 Battery
Spenningen ble endret
Gotion ESC-R125-261 Battery
Den elektriska strømmen ble endret
Gotion ESC-R125-261 Battery
Batteriladestatusen ble endret ...
Gotion ESC-R125-261 Battery
Batterinivået ble endret
Gotion ESC-R125-261 Battery
Temperaturen endres
Gotion ESC-R125-261 Battery
Strømmen ble endret
Gotion ESC-R125-261 PCS
Frekvensen ble endret
Gotion ESC-R125-261 PCS
Temperaturen endres
Gotion ESC-R125-261 PCS
Den generelle alarmen ble aktivert
Gotion ESC-R125-261 PCS
Den generelle alarmen ble deaktivert
Gotion ESC-R125-261 PCS
Røykalarmen ble aktivert
Gotion ESC-R125-261 PCS
Røykalarmen ble deaktivert
Homey Energy Dongle
Strømmen ble endret
Huawei Battery (LUNA)
Batterinivået ble endret
Huawei Battery (LUNA)
Strømmen ble endret
Huawei Battery (LUNA)
Temperaturen endres
Huawei Smart Meter
Strømmen ble endret
Huawei Smart Meter
Frekvensen ble endret
Huawei SUN2000/SUN5000 Hybrid Inverter
Strømmen ble endret
Huawei SUN2000/SUN5000 Hybrid Inverter
Strømmåleren ble endret
OCPP Charger
Strømmen ble endret
OCPP Charger
Den elektriska strømmen ble endret
OCPP Charger
Strømmåleren ble endret
OCPP Charger
Startet lading
OCPP Charger
Stoppet lading
OCPP Charger
Elbilladerens ladestatus ble endret ...
OCPP Charger
Temperaturen endres
Shelly Pro 3EM
Strømmen ble endret
Shelly Pro 3EM
Frekvensen ble endret
Shelly Pro 3EM
Strømmåleren ble endret
Smart Meter - GNM3D-RS485
Strømmåleren ble endret
SolarEdge Energy Meter
Frekvensen ble endret
SolarEdge Energy Meter
Strømmen ble endret
SolarEdge Inverter
Strømmåleren ble endret
SolarEdge Inverter
Strømmen ble endret
Solis S5-GC Inverter
Strømmen ble endret
Solis S5-GC Inverter
Strømmåleren ble endret
Sungrow Battery
Strømmen ble endret
Sungrow Battery
Den elektriska strømmen ble endret
Sungrow Battery
Spenningen ble endret
Sungrow Battery
Batterinivået ble endret
Sungrow Battery
Temperaturen endres
Sungrow Battery
Battery power changed
i
Triggered when the battery power changes. Positive = charging, negative = discharging.
Sungrow Battery
Battery SoC changed
i
Triggered when the battery state of charge changes
Sungrow DTSU666-20 Channel 2
Strømmen ble endret
Sungrow Hybrid Inverter
Strømmen ble endret
Sungrow Hybrid Inverter
Strømmåleren ble endret
Sungrow Hybrid Inverter
Driftstilstanden ble endret til ...
Sungrow Hybrid Inverter
Solar power changed
i
Triggered when the solar power changes
Sungrow Smart Meter
Frekvensen ble endret
Sungrow Smart Meter
Strømmen ble endret
Sungrow Smart Meter
Grid power changed
i
Triggered when the grid power changes. Positive = importing, negative = exporting.
Unmetered PV inverter
Strømmen ble endret
Unmetered PV inverter
Strømmåleren ble endret
Victron Battery
Spenningen ble endret
Victron Battery
Den elektriska strømmen ble endret
Victron Battery
Strømmen ble endret
Victron Battery
Batterinivået ble endret
Victron Battery
Batteriladestatusen ble endret ...
Victron Battery
Temperaturen endres
Victron Grid Meter
Strømmen ble endret
Victron GX (MultiPlus/Quattro ESS)
Spenningen ble endret
Victron GX (MultiPlus/Quattro ESS)
Den elektriska strømmen ble endret
Victron GX (MultiPlus/Quattro ESS)
Strømmen ble endret

Og …

Aikion Controller
Run mode is Mode
Aikion Controller
Automation is enabled
Aikion Controller
Congestion period is active
Charger Box - GLBDC
Lader
Charger Box - GLBDC
Elbilladerens ladestatus er ...
Charger Box - GLBDC
Charger status is Status
Charger Box - GLBDC
Charger mode is Mode
Fronius Battery
Batteriladestatusen er ...
GoodWe Battery
Batteriladestatusen er ...
Gotion ESC-R125-261 Battery
Batteriladestatusen er ...
Gotion ESC-R125-261 PCS
Den generelle alarmen er på
Gotion ESC-R125-261 PCS
Røykalarmen er på
OCPP Charger
Lader
OCPP Charger
Elbilladerens ladestatus er ...
Sungrow Hybrid Inverter
Driftstilstanden er ...
Victron Battery
Batteriladestatusen er ...

Så …

Aikion Controller
Turn automation Automation
Charger Box - GLBDC
Start lading
Charger Box - GLBDC
Stopp lading
Charger Box - GLBDC
Set state to Mode
Charger Box - GLBDC
Set current limit to Current limit A
Deye High Voltage Hybrid 3Phase
Set 5000 W as grid export limit
Deye High Voltage Hybrid 3Phase
Set 100 A as max charge current
Deye High Voltage Hybrid 3Phase
Set 100 A as max discharge current
Deye High Voltage Hybrid 3Phase
Set ... as EMS mode
Deye High Voltage Hybrid 3Phase
Set % % as max SoC
Deye High Voltage Hybrid 3Phase
Set % % as min SoC
Deye High Voltage Hybrid 3Phase
Set % % as shutdown SoC
Deye High Voltage Hybrid 3Phase
Set phase balancing Enabled
Deye High Voltage Hybrid 3Phase
Set grid peak shaving Enabled
Deye High Voltage Hybrid 3Phase
Set 5000 W as grid peak shaving power
Deye High Voltage Hybrid 3Phase
Set combined EMS mode to ... at Power (W) W
Deye High Voltage Hybrid 3Phase
Set battery power to 5000 W for time slot ...
Deye Low Voltage Hybrid 3Phase
Set 5000 W as grid export limit
Deye Low Voltage Hybrid 3Phase
Set 100 A as max charge current
Deye Low Voltage Hybrid 3Phase
Set 100 A as max discharge current
Deye Low Voltage Hybrid 3Phase
Set ... as EMS mode
Deye Low Voltage Hybrid 3Phase
Set % % as max SoC
Deye Low Voltage Hybrid 3Phase
Set % % as min SoC
Deye Low Voltage Hybrid 3Phase
Set % % as shutdown SoC
Deye Low Voltage Hybrid 3Phase
Set phase balancing Enabled
Deye Low Voltage Hybrid 3Phase
Set grid peak shaving Enabled
Deye Low Voltage Hybrid 3Phase
Set 5000 W as grid peak shaving power
Deye Low Voltage Hybrid 3Phase
Set combined EMS mode to ... at Power (W) W
Deye Low Voltage Hybrid 3Phase
Set battery power to 5000 W for time slot ...
Fronius GEN24 Hybrid Inverter
Limit inverter output to 100 % of max power
Fronius GEN24 Hybrid Inverter
Set combined EMS mode to ... at Power (W) W
GoodWe ET Hybrid Inverter
Set 5000 W as grid export limit
GoodWe ET Hybrid Inverter
Set combined EMS mode to ... at Power (W) W
Huawei SUN2000/SUN5000 Hybrid Inverter
Set 5000 W as grid export limit
Huawei SUN2000/SUN5000 Hybrid Inverter
Set combined EMS mode to ... at Power (W) W
OCPP Charger
Start lading
OCPP Charger
Stopp lading
SolarEdge Inverter
Set 0 kW as grid export limit
i
Writes the SolarEdge site limit. With an Export+Import meter this caps grid export; without a meter it caps the inverter's output. 0 kW stops export during negative prices.
Sungrow Battery
Set % % as max SoC
Sungrow Battery
Set % % as min SoC
Sungrow Battery
Set % % as reserved SoC for backup
Sungrow Hybrid Inverter
Set compulsory mode ... with 1.02 kW
Sungrow Hybrid Inverter
Set 1.02 kW as grid export limit
Sungrow Hybrid Inverter
Set 9.4 kW as max charge power
Sungrow Hybrid Inverter
Set 9.2 kW as max discharge power
Sungrow Hybrid Inverter
Set powered up Powered up
Sungrow Hybrid Inverter
Set ... as EMS mode

Støtte

Har du et problem med denne appen? Kontakt utvikleren ved å sende en e-post.

Nyheter

Versjon 3.1.0 — • New: Solis S5-GC grid-tied PV inverters. • New: the Unmetered PV inverter shows its current per phase and has a setting for its phase connection (three-phase or a single phase), which can also be changed in the Aikion app. • Improved: the Unmetered PV estimate follows the actual export on days that are sunnier than forecast. • Improved: the Aikion Controller can no longer be paired while the Reflexion app is running, since both would control the same devices. • Fix: the network scan finds Sungrow inverters again when pairing or repairing. • Fix: changing a Sungrow battery SoC limit now reaches the inverter, and SoC limits show in percent in sliders and flow cards. • Fix: the Sungrow inverter rated power is read correctly. • Fix: control resumes right away after a subscription upgrade.

Vis endringslogg

Aikion

Aikion er ikke kompatibel med den valgte Homey.

Aikion vil straks installeres på Homey.
Installer