Oppdag den nye Homey Portal

Advarsel! Denne appen fungerer kanskje ikke som den skal.

Denne appen er under testing, og har aldri blitt anmeldt. Den fungerer kanskje ikke som forventet.
Vær ekstra forsiktig når du installerer denne appen.

« Tilbake til standardversjonen

24 hours of sun

Les mer ›

Støttede enheter

Flow-kort

Klikk på en enhet ovenfor for å kun vise relaterte Flow-kort.

Når …

Fronius Battery
Strømmen ble endret
Fronius Battery
Batterinivået ble endret
Fronius Battery
Export exceeds Threshold (W) W
i
Triggers when grid export exceeds the specified threshold.
Fronius Battery
Import exceeds Threshold (W) W
i
Triggers when grid import exceeds the specified threshold.
Fronius Battery
Limited charging started
i
Triggers when limited charging mode is activated.
Fronius Battery
Limited charging stopped
i
Triggers when limited charging mode is deactivated.
Fronius Battery
Peak shaving started
i
Triggers when peak shaving mode is activated.
Fronius Battery
Peak shaving stopped
i
Triggers when peak shaving mode is deactivated.
Fronius Battery
Auto zero export started
i
Triggers when auto zero export mode is activated.
Fronius Battery
Auto zero export stopped
i
Triggers when auto zero export mode is deactivated.
Fronius Battery
Battery state changed
Fronius GEN24
Strømmen ble endret
Fronius GEN24
Strømmåleren ble endret
Fronius GEN24
Den generelle alarmen ble aktivert
Fronius GEN24
Den generelle alarmen ble deaktivert
Fronius GEN24
Inverter state changed
Fronius GEN24
Inverter reports a fault
i
Fires when the inverter enters the fault state or raises an event flag.
Fronius Smart Meter
Strømmen ble endret
Fronius Smart Meter
Frekvensen ble endret
Fronius Smart Meter
Den generelle alarmen ble aktivert
Fronius Smart Meter
Den generelle alarmen ble deaktivert
Fronius Smart Meter
Grid voltage became high
i
Fires when a phase reaches the high voltage limit in the device settings (default 253 V). Useful for throttling export or charging the battery to protect production.
Fronius Smart Meter
Grid voltage became normal
i
Fires when all phases are back below the limit minus 2 V.
Fronius Symo
Strømmen ble endret
Fronius Symo
Strømmåleren ble endret
Fronius Symo
Den generelle alarmen ble aktivert
Fronius Symo
Den generelle alarmen ble deaktivert
Fronius Symo
Inverter state changed
Fronius Symo
Inverter reports a fault
i
Fires when the inverter enters the fault state or raises an event flag.

Og …

Fronius Battery
Limited charging is active
i
Check if limited charging mode is currently running.
Fronius Battery
Peak shaving is active
i
Check if peak shaving mode is currently running.
Fronius Battery
Auto zero export is active
i
Check if auto zero export mode is currently running.
Fronius Battery
Battery state is ...
Fronius GEN24
Den generelle alarmen er på
Fronius GEN24
Inverter state is ...
Fronius Smart Meter
Den generelle alarmen er på
Fronius Smart Meter
Grid voltage is high
i
True while any phase is above the high voltage limit.
Fronius Symo
Den generelle alarmen er på
Fronius Symo
Production is limited
Fronius Symo
Zero export is running
Fronius Symo
Inverter state is ...

Så …

Fronius Battery
Disable inverter export limit
i
Enables Modbus override: ramp=0, WMaxLimPct=100%, WMaxLim_Ena=1.
Fronius Battery
Use inverter export limit
i
Disables Modbus override (WMaxLim_Ena=0) so the inverter's Grid Regulations/export limit setting controls export.
Fronius Battery
Discharge at least Discharge power (W) W
i
Forces battery to discharge at minimum this rate, even if the house doesn't need the power (excess is exported). Example: Set to 3000 W but house uses 1000 W → battery discharges 3 kW (1 kW to house, 2 kW exported).
Fronius Battery
Solar mode (allow charge and discharge)
i
Clears all battery restrictions: solar can charge the battery and the battery can discharge for self-consumption. Grid charging stays disabled. Same effect as 'Reset battery control'.
Fronius Battery
Pause (solar charge only, no discharge)
i
Blocks battery discharge but still allows solar excess to charge the battery. Grid charging stays disabled. Use 'Reset battery control' to return to normal.
Fronius Battery
Reset battery control
i
Stops external control: zeros charge/discharge limits and sets StorCtl_Mod=0.
Fronius Battery
Sell solar (allow discharge, block charging)
i
Prevents the battery from charging (solar and grid) so all PV production is exported. Discharge stays allowed for self-consumption. Use 'Reset battery control' to return to normal.
Fronius Battery
Charge at least Charge power (W) W
i
Charges battery at minimum this rate. Pulls power from the grid if solar is insufficient. Example: Set to 3000 W but only 1000 W solar → battery charges at 3 kW (1 kW solar + 2 kW from grid).
Fronius Battery
Discharge at most Discharge power (W) W
i
Limits battery discharge to maximum this rate. If the house needs more power, it pulls from the grid instead. Example: Set to 2000 W and house uses 5000 W → battery provides 2 kW, grid provides 3 kW.
Fronius Battery
Set export limit to Max production (W) W
i
Limits grid export (feed-in) to this W target. Uses WMaxLimPct to cap how much power is sent to the grid. Same register as production limit but different use case.
Fronius Battery
Charge at most Max charge (W) W
i
Limits battery charging to maximum this rate from solar only. Any excess solar power is exported to the grid. Example: Set to 1000 W and you have 3000 W solar → battery charges at 1 kW, 2 kW is exported.
Fronius Battery
Start limited charging up to Max charge (W) W (max import Max grid import (W) W, fuse Main fuse per phase (A, optional) A/phase, interval Check interval (s, min 30) s)
Fronius Battery
Start max export up to Max total export (W) W, updating every Update interval (s) s
i
Maximizes grid export up to target by prioritizing solar production first, then filling remaining capacity with battery discharge. Adjusts automatically as solar changes (clouds).
Fronius Battery
Keep import under Peak target (W) W (duration Duration (minutes, 0 = until stopped) min, interval Update interval (seconds) s)
i
Discharge to keep import below the peak target. Runs periodically until duration expires or stopped.
Fronius Battery
Set production limit to Max production (W) W
i
Limits total inverter AC output (WMaxLimPct) to this W target as percentage of installed capacity. This caps how much the inverter produces regardless of house consumption.
Fronius Battery
Start auto zero export (interval Update interval (seconds) s, duration Duration (minutes, 0 = until stopped) min)
i
Adjusts feed-in limit to keep export near 0 W using Smart Meter. Runs periodically until stopped or duration expires.
Fronius Battery
Stop limited charging
Fronius Battery
Stop max export
i
Stops the max export control loop and resets battery control to normal operation.
Fronius Battery
Stop peak shaving
i
Stops running peak shaving and resets discharge to 0.
Fronius Battery
Remove production limit (restore 100%)
Fronius Battery
Stop auto zero export
i
Stops running auto zero export and disables Modbus override.
Fronius Symo
Limit production to Maximum production W
i
Caps AC production. This is a ceiling, not a target: on a cloudy day the inverter simply produces what it can. Set it to roughly the household load to stop exporting while still covering the house.
Fronius Symo
Remove production limit
i
Lets the inverter produce at full capacity again.
Fronius Symo
Start zero export
i
Trims the production ceiling to keep grid export at zero. The meter already nets off house load, battery charging and any other inverter, so nothing is curtailed while a battery absorbs the surplus - production follows consumption instead of being switched off. Timing and sensitivity are tuned automatically; adjust them under device settings only if you need to.
Fronius Symo
Stop zero export
i
Stops the loop and removes the production limit.

Støtte

Har du et problem med denne appen? Kontakt utvikleren ved å sende en e-post.

Nyheter

Versjon 1.4.6 — New Fronius Smart Meter device: grid power per phase, voltage, frequency and import/export for Homey Energy, with a high grid voltage alert. Solar devices now show production per string, inverter state, faults and temperature. The battery device shows battery state, stored energy and time to full/empty. New Flow triggers and tags for all of it. More reliable reconnection after network dropouts.

Vis endringslogg

Fronius Control

Fronius Control er ikke kompatibel med den valgte Homey.

Fronius Control vil straks installeres på Homey.
Installer