Control Fronius GEN24 inverter and battery via Modbus TCP from Homey Pro.
Requirements
- Homey Pro (local apps)
- Fronius GEN24 with Modbus TCP enabled
- Optional: Fronius Smart Meter (needed for import/export based cards)
Inverter setup (web UI)
1) Communication -> Modbus
- Mode: TCP Server
- SunSpec Model Type: int + SF
- Port: 502
- Allow Control: ON
- Note Meter Address Offset (Smart Meter Unit ID, usually 200)
2) Grid Regulations / Export Limitation (optional)
- Set Maximum grid feed-in power in the inverter UI
- This is used by "Use inverter export limit"
3) Battery charging from grid (optional)
- Enable if you want grid charging
Add device in Homey
- Enter inverter IP/hostname, port and Unit ID (default 1)
- If you use a Smart Meter, set Smart Meter Unit ID (default 200)
Important settings in the app
- Installed PV/site capacity (Wp): total installed PV capacity in Wp (sum of all arrays)
Used by "Limit inverter production to X W"
- Battery max charge/discharge (kW) and optional battery capacity (kWh)
Used to convert W to percent for storage control
- Inverter max AC power (kW) fallback
Notes
- Import-capped charging and zero export run in a loop until stopped.
- Intervals are in seconds (min 30 s for import-capped charging).
- Modbus control can affect inverter and battery behavior. Use at your own risk.
자세히 읽기 ›
Flow 카드
위의 디바이스를 클릭하면 관련 Flow 카드만 표시됩니다.
언제...
Fronius GEN24
소비 전력이 변경되면
그러면...
Fronius GEN24
Allow export (disable inverter limit)
Fronius GEN24
Use inverter export limit
Fronius GEN24
Force discharge Discharge power (W) W
Fronius GEN24
Reset battery control
Fronius GEN24
Set charge power to Charge power (W) W
Fronius GEN24
Set max discharge power to Discharge power (W) W
Fronius GEN24
Limit inverter production to Max production (W) W
Fronius GEN24
Charge up to Max charge (W) W without exceeding Max grid import (W) W import or Main fuse per phase (A, optional) A/phase (check every Check interval (s, min 30) s)
Fronius GEN24
Keep import under Peak target (W) W (duration Duration (minutes, 0 = until stopped) min, interval Update interval (seconds) s)
Fronius GEN24
Limit inverter production to Max production (W) W
Fronius GEN24
Auto zero export (interval Update interval (seconds) s, duration Duration (minutes, 0 = until stopped) min)
Fronius GEN24
Stop import-limited charging
Fronius GEN24
Stop peak shaving
Fronius GEN24
Remove production limit (restore 100%)
Fronius GEN24
Stop auto zero export
지원
이 앱의 개발자는 직접 지원을 제공하지 않습니다.
새로운 기능
버전 1.3.18 — Icon structure fix: copied exact SVG structure (DOCTYPE, version, preserveAspectRatio, g transform) from certified Kvartspris app.
업데이트 로그 보기