Deye Inverter (Local)

Local integration for Deye inverters using Solarman V5 protocol (port 8899)

경고! 이 앱이 제대로 작동하지 않을 수 있습니다.

이 앱 버전은 현재 테스트 중이며 아직 검토되지 않았습니다. 기대한 대로 작동하지 않을 수 있습니다.
이 앱을 설치할 때는 각별히 주의하세요.

« 일반 버전으로 돌아가기

Local integration for Deye inverters using Solarman V5 protocol (port 8899)

자세히 읽기 ›

지원되는 디바이스

Flow 카드

위의 디바이스를 클릭하면 관련 Flow 카드만 표시됩니다.

언제...

Deye Inverter
Battery started charging
i
Triggered when the battery transitions from discharging or standby to charging.
Deye Inverter
Battery started discharging
i
Triggered when the battery transitions from charging or standby to discharging.
Deye Inverter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
Deye Inverter
Inverter data updated
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
Deye Inverter
Fault/alarm detected
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
Deye Inverter
Grid export started
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
Deye Inverter
Grid import started
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
Deye Inverter
Grid connection lost
i
Triggered when the inverter reports a grid outage (hybrid models only).
Deye Inverter
Grid connection restored
i
Triggered when the inverter reports grid power has returned (hybrid models only).
Deye Inverter
Logger went offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
Deye Inverter
Logger came back online
i
Triggered when the logger responds again after an offline period.
Deye Inverter
Solar production started
i
Triggered when the inverter starts producing power (e.g. at sunrise).
Deye Inverter
Solar production stopped
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).
SOFAR Inverter
Battery started charging
i
Triggered when the battery transitions from discharging or standby to charging.
SOFAR Inverter
Battery started discharging
i
Triggered when the battery transitions from charging or standby to discharging.
SOFAR Inverter
Daily data updated
i
Triggered on every successful poll. Use tokens to read today's accumulated energy values. Sell and buy tokens are only available on hybrid inverters with a CT clamp.
SOFAR Inverter
Inverter data updated
i
Triggered on every successful poll (every 60 s by default). Use tokens to read current values. Note: grid_power token is only populated for string inverters — on hybrid models, grid power is tracked by the Grid Meter device.
SOFAR Inverter
Fault/alarm detected
i
Triggered when the inverter transitions from OK into a fault/alarm state (fires once per new fault, not on every poll while it persists).
SOFAR Inverter
Grid export started
i
Triggered when the inverter starts exporting power to the grid (grid meter device).
SOFAR Inverter
Grid import started
i
Triggered when the inverter starts drawing power from the grid (grid meter device).
SOFAR Inverter
Grid connection lost
i
Triggered when the inverter reports a grid outage (hybrid models only).
SOFAR Inverter
Grid connection restored
i
Triggered when the inverter reports grid power has returned (hybrid models only).
SOFAR Inverter
Logger went offline
i
Triggered when the logger is unreachable for the configured number of minutes. Use this instead of (or alongside) the timeline notification.
SOFAR Inverter
Logger came back online
i
Triggered when the logger responds again after an offline period.
SOFAR Inverter
Solar production started
i
Triggered when the inverter starts producing power (e.g. at sunrise).
SOFAR Inverter
Solar production stopped
i
Triggered when the inverter stops producing power (e.g. at sunset or on a fault).

그리고...

Deye Inverter
Battery SOC is above ...%
i
Only available on hybrid inverters with a paired battery device.
Deye Inverter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
Deye Inverter
Fault/alarm is active
Deye Inverter
Battery is charging
i
Only available on hybrid inverters with a paired battery device.
Deye Inverter
Inverter is feeding power to the grid
i
Only available on hybrid inverters with a CT clamp and grid import/export enabled during pairing.
Deye Inverter
Solar production is active
SOFAR Inverter
Battery SOC is above ...%
i
Only available on hybrid inverters with a paired battery device.
SOFAR Inverter
Fault is Fault
i
Checks whether a specific fault/alarm is currently active. Multiple faults can be active at once — this matches if the chosen one is among them. The suggestion list is filtered to what's possible on the selected device's model (e.g. battery faults are hidden for string/micro inverters).
SOFAR Inverter
Fault/alarm is active
SOFAR Inverter
Battery is charging
i
Only available on hybrid inverters with a paired battery device.
SOFAR Inverter
Inverter is feeding power to the grid
i
Only available on hybrid inverters with a CT clamp and grid import/export enabled during pairing.
SOFAR Inverter
Solar production is active

위젯

모바일 앱 내 대시보드 또는 홈 화면에 이 앱의 위젯을 추가할 수 있습니다.

Energy Summary
Energy Summary

지원

이 앱에 문제가 있습니까? 개발자에게 문의하려면 여기를 클릭하세요..

새로운 기능

버전 1.4.16 — Fixed: negative values (battery and grid power, battery current) were 1 unit too small, e.g. 10 W on SOFAR. Fixed: changing the logger IP, model or polling interval (device settings or Repair) only took effect after an app restart, and only on that device — it now applies immediately to the inverter, battery and meter of the same logger. Pairing and Repair no longer collide with the app's own polling on the logger. Deye string inverters: load and grid power (advanced sensors) were 10x too small, and grid power now reads positive when importing, like the hybrid models (per Deye Modbus V118). Deye single-phase hybrid: load power can now be negative instead of jumping to ~65,000 W. "Restore capabilities" on string inverters no longer adds the optional load/grid/energy sensors, which need a CT meter (without one they read 0 or repeat production). New maintenance action on string inverters, "Remove unused values", removes those values, PV3/PV4 inputs that are not wired and a radiator temperature the inverter does not report (-100 °C). Fixed: device Flow triggers (solar production started/stopped, battery charging/discharging, grid export/import, fault, logger offline/online, data updated) never fired. Fixed: unwired PV3/PV4 voltage/current came back on every app restart. "Solar production stopped" and the daily summary now also fire when the inverter goes offline at dusk before production dropped below 5 W, and no longer flip between stopped/started when power hovers around a few watts at dusk (started again only above 25 W). String/micro inverters: a logger that loses power within an hour of sunset or sunrise is treated as night, so there is no daily "Connection failed" warning at dusk; retry attempts no longer fill the diagnostic log. New device setting "Debug logging" (Advanced): when asked for a diagnostic report, turn it on for the device with the problem — it logs every poll and request for that device's logger only, and switches itself off after 60 minutes.

업데이트 로그 보기

Deye Inverter (Local)

선택하신 Homey에 Deye Inverter (Local)이(가) 호환되지 않습니다.

Deye Inverter (Local)이(가) 곧 Homey에 설치됩니다.
앱 설치