Delta Dore Tydom

Native, local Tydom heating in your Homey flows.
Native, local Tydom heating in your Homey flows.

자세히 읽기 ›

지원되는 디바이스

Flow 카드

위의 디바이스를 클릭하면 관련 Flow 카드만 표시됩니다.

언제...

Thermostat
온도가 변경되면
Thermostat
희망 온도가 변경되면
Thermostat
온도조절기 모드가 변경되면 ...
Thermostat
켜지면
Thermostat
꺼지면
Thermostat
배터리 알람이 '예'이면
Thermostat
배터리 알람이 '아니요'이면
Thermostat
Setpoint reached — within Tolerance°C tolerance
i
MODE-AWARE. Fires when the room temperature has hit or passed the setpoint, within [tolerance]°C margin. • In HEATING mode: fires when the room has warmed up to at least (setpoint − tolerance). • In COOLING mode: fires when the room has cooled down to at most (setpoint + tolerance). • In AUTO / OFF: does NOT fire (unclear which direction is 'reached'). Typical use: trigger 'Turn boost off' once the target is reached, regardless of season. Set tolerance to 0 for exact match, or e.g. 0.2°C to end boost slightly before hitting setpoint.
Thermostat
Cannot reach setpoint — off by at least Shortfall°C in the wrong direction
i
MODE-AWARE. Fires when the room temperature is at least [delta]°C off the setpoint in the direction the HVAC is failing. • In HEATING mode: fires when the room is colder than (setpoint − delta). • In COOLING mode: fires when the room is warmer than (setpoint + delta). • In AUTO / OFF: does NOT fire (unclear which direction is 'wrong'). Typical use: trigger 'Turn boost on' when the HVAC is falling behind, regardless of season.
Thermostat
Temperature is at least Delta°C above setpoint
i
Fires when the measured room temperature rises at or above (setpoint + delta). Evaluated on every temperature or setpoint update the thermostat reports.
Thermostat
Temperature is at least Delta°C below setpoint
i
Fires when the measured room temperature falls at or below (setpoint − delta). Evaluated on every temperature or setpoint update the thermostat reports.

그리고...

Thermostat
온도조절기 모드가 다음이면 ...
Thermostat
켜지면
Thermostat
배터리 알람이 '예'이면

그러면...

Thermostat
희망 온도 설정 °C
Thermostat
온도조절기 모드 설정 ...
Thermostat
켜기
Thermostat
끄기
Thermostat
켬/끔 상태 전환하기
Thermostat
Turn boost off
i
Cancels the thermostat boost (clears the setpoint derogation) so the normal schedule / setpoint resumes.
Thermostat
Turn boost on
i
Forces the thermostat to run at max (setpoint 30°C for heating, 10°C for cooling) until boost is turned off. Uses the Tydom setpoint-derogation mechanism.
Thermostat
Turn boost on for Duration (minutes) minute(s)
i
Forces the thermostat to max (30°C heating / 10°C cooling) for a specific duration, then auto-cancels. The Tydom gateway owns the countdown — if power cycles or the app restarts, boost continues until the timer elapses.

지원

이 앱에 문제가 있습니까? 개발자에게 문의하려면 여기를 클릭하세요..

새로운 기능

버전 1.0.3 — Rewritten README that better explains what the app does and why it is useful in Homey flows.

업데이트 로그 보기

Delta Dore Tydom

선택하신 Homey에 Delta Dore Tydom이(가) 호환되지 않습니다.

Delta Dore Tydom이(가) 곧 Homey에 설치됩니다.
앱 설치