Sentinels

Observes existing devices and turns capability updates into activity, cycles, energy and statistics. Read-only — it never controls the devices it monitors.

Avertissement ! Cette appli peut ne pas fonctionner correctement.

Cette appli est en cours de test, et n’a jamais été revue. Il se peut qu’elle ne fonctionne pas comme attendu.
Prenez des précautions supplémentaires en installant cette appli.

« Retour à la version normale

Observes existing devices and turns capability updates into activity, cycles, energy and statistics. Read-only — it never controls the devices it monitors.

Lire plus ›

Cartes Flow

Quand...

Sentinels
Monitor finishes a cycle at least Multiplierx its usual duration
i
Compares the cycle that just finished to the median of this monitor's own history — needs a handful of completed cycles first to have a meaningful median. Simpler and more predictable than statistical anomaly detection (μ±2σ), which struggles with the same skewed, multi-modal duration distributions real appliances produce.
Sentinels
Monitor reaches Cycles cycles today
i
Fires once, the moment a monitor's cycle count for today reaches this exact number — not on every cycle after it. Useful to flag an abnormal on/off frequency (a pump or a compressor cycling far more than usual).
Sentinels
Activity finished (Monitor)
Sentinels
Activity started (Monitor)
Sentinels
Monitor is still running after Multiplierx its usual duration
i
Fires while the cycle is still running, once it reaches the given multiple of this monitor's usual (median) cycle: a pump that usually runs 50 min, with 2, is reported at 1 h 40 min. No Flow needs to check every few minutes. Needs a handful of completed cycles first to know the usual duration. The message token comes in the Default message language.
Sentinels
Device battery is low
i
Fires once when a watched device's battery drops to the warning level set in Settings -> Availability (30 % unless changed), and stays low for the configured delay. Fires again only after the battery has recovered and dropped again.
Sentinels
Device battery is OK again
i
Fires once when a watched device whose battery was reported low is above the warning level again, usually after a battery change.
Sentinels
Device became available again
i
Fires when a watched device recovers — its available flag returns true, or it starts reporting again after going stale.
Sentinels
Device became unavailable
i
Fires when a watched device's own available flag turns false, or when it goes longer than its configured threshold without reporting (catches drivers that never manage available themselves). Configure which devices are watched, and for how many hours, in Settings → Availability or with "Add availability watchdog".
Sentinels
A device stopped reporting, is unavailable or has a low battery
i
Fires once for each device that newly turns up as a problem in the all-devices scan (Settings -> Availability), for devices that have no watchdog of their own. The very first scan only records what is already wrong. At most 10 per scan; a summary also goes to the Homey timeline.
Sentinels
Group is back to normal
i
Fires the next time a poll finds every device back in the expected state, after the group had a mismatch.
Sentinels
Group has a new mismatch
i
Fires the moment a poll first finds a mismatch in this group — not again on every following poll while it stays mismatched. Checked every few minutes (same cadence as the group's own statistics poll), so this can lag the real moment by up to that interval; use "Check state group" instead for an instant, on-demand check.
Sentinels
State session finished (Monitor)
Sentinels
State session started (Monitor)
Sentinels
Threshold calibrated (Monitor)
i
Fires once, the first time a monitor created without a threshold finishes auto-calibrating from its own power history.
Sentinels
Overvoltage detected (Monitor)
Sentinels
Voltage returned to normal (Monitor)
Sentinels
Undervoltage detected (Monitor)

Et...

Sentinels
Monitor has not been active for at least Hours hours
i
True when the monitor is idle and its last cycle ended at least this long ago (for a monitor that has not finished a cycle yet, since it was first seen). False while it is running, or before it has recorded anything. For a freezer, a pump or a door that should have cycled by now. Works with Activity and State monitors.
Sentinels
Monitor has been active for more than Minutes minutes
i
Activity and state monitors: a pump running for more than 2 hours, a door open for more than 10 minutes.
Sentinels
Device is available
i
Checks the device's own available flag right now — no watchdog needs to be configured for this. Only accurate for devices whose driver actively manages availability; one that never does will always read "available" even if it's dead. Add an availability watchdog for that device instead to also catch staleness.
Sentinels
Device is already monitored
i
Checks whether this device already has an activity, state, or voltage monitor configured on it — useful to guard a Flow that creates monitors dynamically against adding a duplicate.
Sentinels
Monitor is active
i
An Activity monitor is active while it runs; a State monitor while it is in its on/open state. For a Voltage monitor use "Voltage is in state".
Sentinels
Monitor has had a reading in the last Minutes minutes
i
For any Activity, State or Voltage monitor: catches a device that still shows as available but stopped sending its value. Homey only sends a value when it changes, so pick a window longer than the quiet times of that device.
Sentinels
Group has a mismatch
Sentinels
Monitor usually does not start in this hour (under Percent % of its cycles)
i
True when fewer than this percent of the monitor's cycles started in the current hour of the day (your time zone), so a start now is out of the ordinary. Use it after Activity started: a fryer on at 3 am. False until the monitor has at least 20 cycles to learn from. Works with Activity and State monitors.
Sentinels
Monitor is in state State
Sentinels
Monitor A and Monitor B differ by more than Percent%
i
Compares the current reading of two Voltage monitors (e.g. two phases of a three-phase meter, watched as separate monitors) as a percent of their average: |A - B| / ((A + B) / 2) x 100. For more than two phases, chain this condition once per pair with AND/OR. Compare monitors that read the same thing (phase-neutral with phase-neutral, phase-phase with phase-phase). False while either monitor has no reading yet.

Alors...

Sentinels
Recalibrate threshold for Monitor
i
Re-enables auto-calibration for an activity monitor that already has a threshold (manually set or previously calibrated) — the next time enough power history confirms a new standby/active split, the threshold updates automatically, same as a freshly created monitor. Existing history and current threshold are kept until then.
Sentinels
Check state group Group, expected Expected state override (optional)
i
Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Export all Sentinels data as JSON
i
Returns the entire store — every monitor's configuration, history and stats — as one JSON string token. Meant for a backup/inspection flow (e.g. an HTTP request or a file-writing app), not a plain notification — check the size token first if you're about to put it somewhere with a size limit. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Generate text report for Monitor, period: Period
i
Builds one ready-to-use sentence summarizing an activity/state/voltage monitor's statistics for the period — for a push notification or chat message without concatenating a dozen tokens by hand. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get activity statistics for Monitor, period: Period
i
Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get daily digest
i
Today in one message for a notification: the cycles and energy of your Activity monitors since midnight, the biggest user, the devices the last availability scan flagged (0 while that scan is off) and the state groups with a mismatch now. The sentence follows the Default message language in Settings; the numbers are there to build your own. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get group statistics for Group, period: Period
i
A group has no continuous per-device history (see "[Group] has a mismatch"'s own limitation) — but the app polls every group every few minutes and keeps a light daily tally of how often and for how long it found a mismatch, which this reads. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get standby ranking, period: Period
i
Which monitors use the most energy while idle, over the period: the total, the biggest one and a top 5 as ready-to-use lines (name and kWh). Needs a device that reports kWh. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get state statistics for Monitor, period: Period
i
Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get usage pattern of Monitor, period: Period
i
When a monitor is used: the busiest weekday and hour of its cycles how much of its time on falls in the day (06:00 to 22:00), the energy over the period and the hour with the highest average power, worked out from the cycles it already keeps. Needs at least 5 cycles in the period. The weekday name and the sentence follow the Default message language in Settings. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Get voltage statistics for Monitor, period: Period
i
Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Reset the statistics of Monitor
i
For any Activity, State or Voltage monitor: wipes its recorded history and live state (e.g. after fixing a monitor that recorded wrong data) and keeps the monitor itself, its device, capability and settings.
Sentinels
Start monitoring device Device, name Monitor name (optional)
i
For an on/off-only device (a pump, a device with no reliable standby signal) — creates the monitor on first run if it doesn't exist yet, then starts it, in one step. Meant to be driven by a native "Power becomes greater than X" trigger (or any other Flow logic) instead of this app's own threshold engine. The resulting monitor never decides active/standby on its own — only this card and "Stop monitoring device" do. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Stop monitoring device Device
i
Closes the cycle started by "Start monitoring device" for this device — fires "Activity finished" with duration, energy and the rest of the usual tokens. Fails if no monitor exists yet for this device; run "Start monitoring device" first. Its tokens are only available in an Advanced Flow.
Advanced
Sentinels
Update activity monitor Monitor to threshold Activity threshold (W) W, continuity Continuity window (minutes, optional) min, min. confirmation Minimum state confirmation (seconds, optional) s
Sentinels
Update voltage monitor Monitor to range Minimum voltage (V)-Maximum voltage (V) V

Widgets

Vous pouvez ajouter les widgets de cette application à votre tableau de bord ou à votre écran d’accueil dans l’application mobile.

Sentinels Watchdogs
Sentinels Watchdogs
Sentinels Health
Sentinels Health
Sentinels Overview
Sentinels Overview
Sentinel
Sentinel
Sentinels Timeline
Sentinels Timeline
Sentinels Voltage
Sentinels Voltage

Assistance

Le développeur de cette appli ne propose pas d’assistance directe.

Nouveautés

Version 1.0.12 — "Still running long" now has a ready message in your Default message language, also shown in the Timeline. State monitors whose device also reports power keep their real peak power in Get usage pattern, and State statistics show power and energy only when the device reports them.

Afficher le journal des modifications

Sentinels

Cette appli peut gérer tout votre Homey.

Sentinels n’est pas compatible avec le Homey sélectionné.

Sentinels va s’installer sur Homey dans un instant.
Installer