Avertissement ! Cette appli peut ne pas fonctionner correctement.
Cette appli est en cours de test, et n’a jamais été revue. Il se peut qu’elle ne fonctionne pas comme attendu. Prenez des précautions supplémentaires en installant cette appli.
Purpose-built drivers cover the most common Tuya smart home device types — from air conditioners, smart plugs and lights to garage doors, heat pumps and curtain motors. Each driver automatically detects the device's data points at pairing time and maps them to the right Homey capabilities, so most devices are ready to use straight away. A generic driver is included for any device type not covered by the dedicated drivers.
All communication runs directly over your local Wi-Fi network. Devices respond instantly to Homey commands and push state changes in real time, even without an internet connection. Every driver comes with a full set of Flow cards — triggers, conditions and actions — tailored to its device type, so you can build automations the moment your device is added.
Cliquez sur un appareil ci-dessus pour afficher uniquement les cartes Flow associées.
Quand...
Air Conditioner
Activé
Air Conditioner
Désactivé
Air Conditioner
La température cible a été modifiée
Air Conditioner
La température a changé
Air Conditioner
AC connected
Air Conditioner
AC disconnected
Air Conditioner
AC data point changed
Air Conditioner
AC fault alarm triggered
Air Conditioner
AC mode changed
Air Conditioner
AC child lock was Child lock
Air Quality Monitor
Le niveau de qualité de l'air est passé à ...
Air Quality Monitor
La valeur PM2.5 a changé
Air Quality Monitor
La valeur PM1 a changé
Air Quality Monitor
La valeur PM10 a changé
Air Quality Monitor
Le niveau de CO₂ a changé
Air Quality Monitor
Le niveau de CO a changé
Air Quality Monitor
Le niveau de formaldéhyde a changé
Air Quality Monitor
La valeur du TVOC a changé
Air Quality Monitor
La température a changé
Air Quality Monitor
L'humidité a changé
Air Quality Monitor
Le niveau de la batterie a changé
Air Quality Monitor
L'alarme batterie s'est activée
Air Quality Monitor
L'alarme batterie s'est désactivée
Air Quality Monitor
L'état de charge de la batterie a changé ...
Air Quality Monitor
L'alarme CO₂ s'est activée
Air Quality Monitor
L'alarme CO₂ s'est désactivée
Air Quality Monitor
L'alarme CO s'est activée
Air Quality Monitor
L'alarme CO s'est désactivée
Air Quality Monitor
L'alarme PM2.5 s'est activée
Air Quality Monitor
L'alarme PM2.5 s'est désactivée
Air Quality Monitor
Monitor connected
Air Quality Monitor
Monitor disconnected
Air Quality Monitor
Monitor data point changed
Air Quality Monitor
Air quality level changed
i
Fires when the monitor’s own overall verdict moves to another step — not on every changed measurement. The step it came from is a token, so a flow can tell getting better from getting worse.
Air Quality Monitor
PM0.3 rose above PM0.3 (µg/m³) µg/m³
i
Fires the moment the reading crosses the threshold in the card, not on every reading above it. PM0.3 is the one measurement Homey has no card of its own for.
Air Quality Monitor
Alarm volume changed
i
Fires when the monitor reports a different alarm volume — whether it was changed from Homey or on the monitor itself.
Air Quality Monitor
Display backlight changed
Air Quality Monitor
Buzzer was Buzzer
Ceiling Fan Light
Activé
Ceiling Fan Light
Désactivé
Ceiling Fan Light
Intensité lumineuse modifiée
Ceiling Fan Light
Ceiling fan light connected
Ceiling Fan Light
Ceiling fan light disconnected
Ceiling Fan Light
Fan data point changed
Ceiling Fan Light
Fan mode changed
Ceiling Fan Light
Fan direction changed
Ceiling Fan Light
The fan was Fan
i
Homey supplies the equivalent for the light by itself, because on this driver the light is the fitting’s main switch. The fan has its own switch beside it, and this is the card that watches it.
Ceiling Fan Light
Ceiling fan child lock was Child lock
Ceiling Fan Light
Ceiling fan oscillation was Oscillation
Curtain Motor
L'état a été modifié ...
Curtain Motor
La position a changé
Curtain Motor
Fermé
Curtain Motor
Ouvert
Curtain Motor
Curtain fully opened
Curtain Motor
Curtain fully closed
Curtain Motor
Curtain position changed
Curtain Motor
Curtain motor fault triggered
Curtain Motor
Curtain motor connected
Curtain Motor
Curtain motor disconnected
Curtain Motor
Curtain motor data point changed
Dehumidifier
Activé
Dehumidifier
Désactivé
Dehumidifier
L'humidité a changé
Dehumidifier
La vitesse de ventilation a changé
Dehumidifier
L'humidité cible a changé
Dehumidifier
Humidity went above Humidity (%)%
Dehumidifier
Humidity dropped below Humidity (%)%
Dehumidifier
Water tank became full
Dehumidifier
Water tank was emptied
Dehumidifier
Dehumidifier connected
Dehumidifier
Dehumidifier disconnected
Dehumidifier
A data point changed
Dehumidifier
Dehumidifier child lock was Child lock
Dehumidifier
Dehumidifier oscillation was Oscillation
Doorbell
L'alarme générique s'est activée
Doorbell
L'alarme générique s'est désactivée
Doorbell
Doorbell rang
Doorbell
Doorbell motion detected
Doorbell
Doorbell connected
Doorbell
Doorbell disconnected
Doorbell
Doorbell data point changed
Energy Meter
L'énergie a changé
Energy Meter
Le voltage a changé
Energy Meter
Le courant électrique a changé
Energy Meter
Energy meter connected
Energy Meter
Energy meter disconnected
Energy Meter
A data point changed
EV Charger
Charge démarrée
EV Charger
Charge arrêtée
EV Charger
L'état de charge du chargeur VE a changé ...
EV Charger
La puissance cible a été modifiée
EV Charger
L'énergie a changé
EV Charger
Le voltage a changé
EV Charger
Le courant électrique a changé
EV Charger
Charger connected
EV Charger
Charger disconnected
EV Charger
Charging session finished
i
Fires when the charger leaves the charging state, with the energy delivered in that session as a token. For a plain start/stop trigger use the built-in "Started charging" / "Stopped charging" cards.
EV Charger
Detailed charger state changed
i
Fires on any change of the charger's raw Tuya state, which is more granular than Homey's standard charging state (it tells "waiting", "finished" and "plugged in" apart).
EV Charger
Charging mode changed
i
Fires when the charger reports a different charging mode (Tuya work_mode, usually DP 14) — whether it was changed from Homey, from the charger, or from the manufacturer's own app. Requires DP Work Mode to be set in device settings.
EV Charger
Charger fault occurred
EV Charger
Charger data point changed
Fan
Activé
Fan
Désactivé
Fan
Intensité lumineuse modifiée
Fan
Fan connected
Fan
Fan disconnected
Fan
Fan data point changed
Fan
Fan mode changed
Fan
Fan direction changed
Fan
Fan child lock was Child lock
Fan
Fan oscillation was Oscillation
Garage Door
Fermé
Garage Door
Ouvert
Garage Door
Garage door opened
Garage Door
Garage door closed
Garage Door
Garage door alarm triggered
Garage Door
Garage door opener connected
Garage Door
Garage door opener disconnected
Garage Door
Garage door data point changed
Generic Tuya Device
A data point changed
Generic Tuya Device
DP DP number changed
i
Fires only when the given DP number changes value. Use the Value / Previous Value tokens in the notification text or a further AND card.
Generic Tuya Device
Device connected
Generic Tuya Device
Device disconnected
Heat Pump
Activé
Heat Pump
Désactivé
Heat Pump
La température cible a été modifiée
Heat Pump
La température a changé
Heat Pump
Heat pump mode changed
Heat Pump
Heat pump fault alarm triggered
Heat Pump
Heat pump connected
Heat Pump
Heat pump disconnected
Heat Pump
Heat pump data point changed
Heat Pump
Silent mode changed
Heater
Activé
Heater
Désactivé
Heater
La température cible a été modifiée
Heater
Heater connected
Heater
Heater disconnected
Heater
Heater data point changed
Heater
Heater started heating
Heater
Heater stopped heating
Heater
Heater fault alarm triggered
Heater
Heater child lock was Child lock
Heater
Heater oscillation was Oscillation
Humidifier
Activé
Humidifier
Désactivé
Humidifier
L'humidité a changé
Humidifier
La vitesse de ventilation a changé
Humidifier
L'humidité cible a changé
Humidifier
Humidity went above Humidity (%)%
Humidifier
Humidity dropped below Humidity (%)%
Humidifier
Water tank became empty
Humidifier
Water tank was refilled
Humidifier
Humidifier connected
Humidifier
Humidifier disconnected
Humidifier
Humidifier data point changed
Humidifier
Humidifier child lock was Child lock
IR Blaster
La température a changé
IR Blaster
L'humidité a changé
IR Blaster
Blaster connected
IR Blaster
Blaster disconnected
IR Blaster
Blaster data point changed
IR Blaster
An IR code was learned
i
Fires when a code arrives from the blaster, however learning was started — from a flow, or by putting the blaster into learning mode yourself. The code is a token, so it can be handed straight to "Send a raw IR code" on another blaster.
Light
Activé
Light
Désactivé
Light
Intensité lumineuse modifiée
Light
Light connected
Light
Light disconnected
Light
Light data point changed
Pet Feeder
Food level changed
Pet Feeder
Feeding completed
Pet Feeder
Pet feeder connected
Pet Feeder
Pet feeder disconnected
Pet Feeder
Pet feeder data point changed
Pet Feeder
Feeder child lock was Child lock
Presence Sensor
L'alarme mouvement s'est activée
Presence Sensor
L'alarme mouvement s'est désactivée
Presence Sensor
L'alarme générique s'est activée
Presence Sensor
L'alarme générique s'est désactivée
Presence Sensor
La distance a changé
Presence Sensor
La luminance a changé
Presence Sensor
Presence detected
Presence Sensor
Presence cleared
Presence Sensor
Presence sensor connected
Presence Sensor
Presence sensor disconnected
Presence Sensor
Presence sensor data point changed
Smart Kettle
Activé
Smart Kettle
Désactivé
Smart Kettle
La température a changé
Smart Kettle
Kettle connected
Smart Kettle
Kettle disconnected
Smart Kettle
A data point changed
Smart Kettle
Kettle status changed
Smart Kettle
Kettle finished boiling
Smart Plug
Activé
Smart Plug
Désactivé
Smart Plug
L'énergie a changé
Smart Plug
Le voltage a changé
Smart Plug
Le courant électrique a changé
Smart Plug
Le compteur électrique a changé
Smart Plug
Smart plug connected
Smart Plug
Smart plug disconnected
Smart Plug
A data point changed
Smart Plug
Power went above Power (W) W
Smart Plug
Power dropped below Power (W) W
Smart Plug
Smart plug fault alarm triggered
Smoke Detector
L'alarme fumée s'est activée
Smoke Detector
L'alarme fumée s'est désactivée
Smoke Detector
Le niveau de la batterie a changé
Smoke Detector
L'alarme batterie s'est activée
Smoke Detector
L'alarme batterie s'est désactivée
Smoke Detector
L'alarme sabotage s'est activée
Smoke Detector
L'alarme sabotage s'est désactivée
Smoke Detector
L'alarme générique s'est activée
Smoke Detector
L'alarme générique s'est désactivée
Smoke Detector
Detector connected
Smoke Detector
Detector disconnected
Smoke Detector
Self-test finished
i
Fires when the detector reports the outcome of a self-test, however it was started — from a flow, or by pressing the button on the detector itself.
Smoke Detector
Detector data point changed
Smoke Detector
Smoke level rose above Smoke level (ppm) ppm
i
Fires the moment the reading crosses the threshold, not on every reading above it. An early warning: the concentration rises before the detector sounds.
Thermostat
Activé
Thermostat
Désactivé
Thermostat
La température cible a été modifiée
Thermostat
La température a changé
Thermostat
Thermostat connected
Thermostat
Thermostat disconnected
Thermostat
A data point changed
Thermostat
Thermostat mode changed
Thermostat
Thermostat child lock was Child lock
Ultrasonic Level Sensor
Level state changed
Ultrasonic Level Sensor
Level sensor connected
Ultrasonic Level Sensor
Level sensor disconnected
Ultrasonic Level Sensor
Level sensor data point changed
Ultrasonic Level Sensor
Liquid level rose above Level (%)%
Ultrasonic Level Sensor
Liquid level dropped below Level (%)%
Wall Switch
Activé
Wall Switch
Désactivé
Wall Switch
Wall switch connected
Wall Switch
Wall switch disconnected
Wall Switch
A data point changed
Wall Switch
Switch Gang changed
Weather Station
La température a changé
Weather Station
Comfort level changed
Weather Station
Weather station connected
Weather Station
Weather station disconnected
Weather Station
Weather station data point changed
Et...
Air Conditioner
Est activé
Air Conditioner
AC is connected
Air Conditioner
AC mode is Mode
Air Conditioner
AC fan speed is Fan Speed
Air Conditioner
AC sleep mode is on
Air Conditioner
AC fault alarm is active
Air Conditioner
AC child lock is on
Air Quality Monitor
La qualité de l'air est ...
Air Quality Monitor
L'alarme batterie est en marche
Air Quality Monitor
L'état de charge de la batterie est ...
Air Quality Monitor
L'alarme CO₂ est activée
Air Quality Monitor
L'alarme CO est en marche
Air Quality Monitor
L'alarme PM2.5 est en marche
Air Quality Monitor
Monitor is connected
Air Quality Monitor
PM0.3 is above PM0.3 µg/m³
Air Quality Monitor
Alarm volume is Volume
i
Worth checking before a flow relies on the monitor to wake somebody: a monitor left on mute measures exactly as well and says nothing.
Air Quality Monitor
Display backlight is Level
Air Quality Monitor
Buzzer is on
Ceiling Fan Light
Est activé
Ceiling Fan Light
Ceiling fan light is connected
Ceiling Fan Light
Fan mode is Mode
Ceiling Fan Light
Fan direction is ...
Ceiling Fan Light
Fan is running
Ceiling Fan Light
The fan is oscillating
Ceiling Fan Light
Fan speed is Fan speed
Ceiling Fan Light
The child lock is on
Curtain Motor
L'état est ...
Curtain Motor
Sont fermés
Curtain Motor
Curtain is open (> 50%)
Curtain Motor
Curtain is fully closed
Curtain Motor
Curtain is moving
Curtain Motor
Curtain motor is connected
Dehumidifier
Est activé
Dehumidifier
Humidity is above Humidity (%)%
Dehumidifier
Humidity is below Humidity (%)%
Dehumidifier
Water tank is full
Dehumidifier
Dehumidifier is connected
Dehumidifier
Mode is Mode
Dehumidifier
Dehumidifier child lock is on
Dehumidifier
Dehumidifier oscillation is on
Doorbell
L'alarme générique est en marche
Doorbell
Doorbell motion is active
Doorbell
Night light is on
Doorbell
Doorbell is connected
Energy Meter
Energy meter is connected
Energy Meter
Power is above Watts W
Energy Meter
Current is above Amps A
i
Useful as an overload warning on a circuit whose breaker rating you know.
Energy Meter
Fault is active
EV Charger
N'est en cours de charge
EV Charger
L'état de charge du chargeur VE est ...
EV Charger
Charger is connected
EV Charger
Detailed charger state is State
i
Checks the charger's raw Tuya state, which distinguishes "waiting", "finished" and "plugged in" — states that Homey's standard charging state groups together.
EV Charger
Charging mode is Mode
i
Reads the value the charger reports on its work mode data point. A charger that does not implement a mode simply never reports it.
Fan
Est activé
Fan
Fan is connected
Fan
Light is on
Fan
Fan mode is Mode
Fan
Fan direction is ...
Fan
Fan child lock is on
Fan
Fan oscillation is on
Garage Door
Est fermé
Garage Door
Garage door is open
Garage Door
Garage door opener is connected
Generic Tuya Device
Device is connected
Generic Tuya Device
DP DP number value is Value
i
Compares the last known value of a DP. Value is parsed automatically: 'true'/'false' → boolean, numbers → number, everything else → string.
Heat Pump
Est activé
Heat Pump
Heat pump is on
Heat Pump
Heat pump fault alarm is active
Heat Pump
Heat pump is connected
Heat Pump
Silent mode is on
Heater
Est activé
Heater
Heater is connected
Heater
Heater is actively heating
Heater
Heater fault alarm is active
Heater
Heating level is Level
Heater
Heater mode is Mode
Heater
Heater child lock is on
Heater
Heater oscillation is on
Humidifier
Est activé
Humidifier
Humidifier is connected
Humidifier
Humidity is above Humidity (%)%
Humidifier
Humidity is below Humidity (%)%
Humidifier
Water tank is empty
Humidifier
Humidifier child lock is on
IR Blaster
Blaster is connected
Light
Est activé
Light
Light is connected
Light
Light colour mode is Mode
Pet Feeder
Food level is low
Pet Feeder
Pet feeder is connected
Pet Feeder
Feeder child lock is on
Presence Sensor
L'alarme mouvement est en marche
Presence Sensor
L'alarme générique est en marche
Presence Sensor
Presence is detected
Presence Sensor
Presence sensor is connected
Smart Kettle
Est activé
Smart Kettle
Kettle is connected
Smart Kettle
Kettle is heating
Smart Plug
Est activé
Smart Plug
Smart plug is connected
Smart Plug
Fault alarm is active
Smart Plug
Power is above Power (W) W
Smoke Detector
L'alarme fumée est en marche
Smoke Detector
L'alarme batterie est en marche
Smoke Detector
L'alarme sabotage est en marche
Smoke Detector
L'alarme générique est en marche
Smoke Detector
Detector is connected
Smoke Detector
Smoke level is above Smoke level (ppm) ppm
Thermostat
Est activé
Thermostat
Thermostat is connected
Thermostat
Mode is Mode
Thermostat
Thermostat child lock is on
Ultrasonic Level Sensor
Level state is State
Ultrasonic Level Sensor
Liquid level is above Level (%)%
Ultrasonic Level Sensor
Level sensor is connected
Wall Switch
Est activé
Wall Switch
Wall switch is connected
Wall Switch
Switch Gang is on
Weather Station
Comfort level is Comfort
Weather Station
Wind speed is above km/h km/h
Weather Station
Wind is from the Direction
i
Each direction covers a 90° sector, so “north” means anything from north-west round to north-east.
Weather Station
Weather station is connected
Alors...
Air Conditioner
Activer
Air Conditioner
Désactiver
Air Conditioner
Alterner activé ou désactivé
Air Conditioner
Définir la température °C
Air Conditioner
Set AC mode to Mode
Air Conditioner
Set AC fan speed to Fan Speed
Air Conditioner
Set AC target temperature to Temperature (°C) °C
Air Conditioner
Set AC swing to Swing
Air Conditioner
Set AC sleep mode Sleep
Air Conditioner
Set AC ECO mode ECO
Air Conditioner
Set AC ioniser Ioniser
Air Conditioner
Set AC horizontal swing Horizontal swing
Air Conditioner
Set AC child lock Child lock
Air Conditioner
Force AC reconnect
Air Conditioner
Refresh AC device
Air Conditioner
Set AC timer Duration
Air Quality Monitor
Set alarm volume to Volume
i
Mute is the one to reach for at night. It silences the monitor’s own buzzer, not Homey — the readings and the alarms in this app carry on.
Air Quality Monitor
Set display backlight to Level
Air Quality Monitor
Turn the buzzer State
Air Quality Monitor
Force monitor reconnect
Air Quality Monitor
Refresh monitor values
Ceiling Fan Light
Activer
Ceiling Fan Light
Désactiver
Ceiling Fan Light
Alterner activé ou désactivé
Ceiling Fan Light
Mettre l'intensité lumineuse sur %
Ceiling Fan Light
Définir l'intensité lumineuse sur relative %
i
Diminuez ou augmentez la luminosité par rapport au niveau actuel de l'appareil.
Ceiling Fan Light
Set fan mode to Mode
Ceiling Fan Light
Set fan speed to Fan Speed
Ceiling Fan Light
Set fan oscillation Oscillate
Ceiling Fan Light
Force ceiling fan light reconnect
Ceiling Fan Light
Refresh ceiling fan light values
Ceiling Fan Light
Set fan direction to ...
Ceiling Fan Light
Set timer to Duration
Ceiling Fan Light
Turn the fan Fan
Ceiling Fan Light
Set fan speed to Speed%
i
For fittings whose speed is a number rather than a named step. The percentage is mapped onto the range in the device settings, so 100% is the fitting’s own highest step — six on most of them. Use “Set fan speed” instead where the fitting names its steps.
Ceiling Fan Light
Set the child lock Child lock
Ceiling Fan Light
Set light mode to Mode
i
Sends a mode token to the light's own mode data point — including scene and music, which the standard light controls cannot express. Requires the Light Mode DP in device settings.
Curtain Motor
Définir l'état ...
Curtain Motor
Mettre la position sur %
i
Réglez la position sur ouvert (100 %), fermé (0 %) ou une valeur intermédiaire.
Curtain Motor
Fermer
Curtain Motor
Ouvrir
Curtain Motor
Alterner ouvert/fermé
Curtain Motor
Open curtain
Curtain Motor
Close curtain
Curtain Motor
Stop curtain
Curtain Motor
Set curtain position to Position (%)%
Curtain Motor
Move curtain to favourite position
Curtain Motor
Force curtain motor reconnect
Curtain Motor
Refresh curtain motor values
Dehumidifier
Activer
Dehumidifier
Désactiver
Dehumidifier
Alterner activé ou désactivé
Dehumidifier
Définir la vitesse de ventilation sur %
Dehumidifier
Définir l'humidité %
Dehumidifier
Set target humidity to Target humidity (%)%
Dehumidifier
Set mode to Mode
Dehumidifier
Set fan speed to Fan Speed
Dehumidifier
Set timer to Duration
Dehumidifier
Set child lock Child Lock
Dehumidifier
Set ioniser Ioniser
Dehumidifier
Set dehumidifier oscillation Oscillate
Dehumidifier
Set self-clean Self-Clean
Dehumidifier
Set water pump Water Pump
Dehumidifier
Force dehumidifier reconnect
Dehumidifier
Refresh dehumidifier values
Doorbell
Enable motion detection
Doorbell
Disable motion detection
Doorbell
Force doorbell reconnect
Doorbell
Refresh doorbell values
Doorbell
Set night vision to Mode
Doorbell
Set chime volume to Volume (0–100)
Doorbell
Turn night light State
Doorbell
Turn alarm reporting State
Doorbell
Set ring tone to Melody number
Doorbell
Set motion sensitivity to Sensitivity
Energy Meter
Force energy meter reconnect
Energy Meter
Refresh energy meter values
EV Charger
Démarrer la charge
EV Charger
Arrêter la charge
EV Charger
Définir la puissance cible W
i
Cela règle également le mode de puissance cible sur Homey. Pour les bornes de recharge, la recharge démarre ou s'arrête automatiquement.
EV Charger
Set charge current to Current A
i
Clamped to the Current Min / Current Max range configured in device settings.
EV Charger
Set charging mode to Mode
i
Switches the charger between immediate, scheduled and target-based charging. Useful before "Start charging": several chargers ignore the charge switch while they are in scheduled mode. Not every charger implements every mode — one it does not know is discarded without an error, so check DP Debug after the first try.
EV Charger
Reset energy meter
EV Charger
Force charger reconnect
EV Charger
Refresh charger values
Fan
Activer
Fan
Désactiver
Fan
Alterner activé ou désactivé
Fan
Mettre l'intensité lumineuse sur %
Fan
Définir l'intensité lumineuse sur relative %
i
Diminuez ou augmentez la luminosité par rapport au niveau actuel de l'appareil.
Fan
Set fan mode to Mode
Fan
Set fan speed to Fan Speed
Fan
Set fan oscillation Oscillate
Fan
Force fan reconnect
Fan
Refresh fan values
Fan
Set fan direction to ...
Fan
Set timer to Duration
Fan
Turn light Light
Fan
Set light brightness to Brightness%
Fan
Set light mode to Mode
i
Sends a mode token to the light's own mode data point — including scene and music, which the standard light controls cannot express. Requires the Light Mode DP in device settings.
Fan
Set fan child lock Child lock
Garage Door
Fermer
Garage Door
Ouvrir
Garage Door
Alterner ouvert/fermé
Garage Door
Open garage door
Garage Door
Close garage door
Garage Door
Toggle garage door
Garage Door
Stop garage door
Garage Door
Force garage door opener reconnect
Garage Door
Refresh garage door values
Generic Tuya Device
Force reconnect
Generic Tuya Device
Refresh device values
Generic Tuya Device
Set DP DP number to Value
i
Send a raw data point (DP) command. Value is parsed automatically: 'true'/'false' → boolean, numbers → integer/float, everything else → string.
Heat Pump
Activer
Heat Pump
Désactiver
Heat Pump
Alterner activé ou désactivé
Heat Pump
Définir la température °C
Heat Pump
Set heat pump mode to Mode
Heat Pump
Set heat pump preset to Preset
Heat Pump
Force heat pump reconnect
Heat Pump
Refresh heat pump values
Heat Pump
Turn silent mode ...
Heater
Activer
Heater
Désactiver
Heater
Alterner activé ou désactivé
Heater
Définir la température °C
Heater
Set heater mode to Mode
Heater
Set heater target temperature to Temperature (°C) °C
Heater
Set heating level to Level
i
The heating power step. These heaters offer named steps rather than a percentage, so the choices come from what your device declares.
Heater
Set heater oscillation Oscillate
Heater
Set heater child lock Child lock
Heater
Force heater reconnect
Heater
Refresh heater values
Heater
Set heater timer Duration
Humidifier
Activer
Humidifier
Désactiver
Humidifier
Alterner activé ou désactivé
Humidifier
Définir la vitesse de ventilation sur %
Humidifier
Définir l'humidité %
Humidifier
Set target humidity to Target humidity (%)%
Humidifier
Set humidifier mode to Mode
Humidifier
Set humidifier fan speed to Fan Speed
Humidifier
Force humidifier reconnect
Humidifier
Refresh humidifier values
Humidifier
Set humidifier ioniser Ioniser
Humidifier
Set humidifier child lock Child lock
Humidifier
Set humidifier timer Duration
IR Blaster
Send the IR code Saved code
i
Sends a code this blaster learned earlier. The list is the blaster’s own — a code learned on one is not on another until it is learned there too, or copied across with "Send a raw IR code".
IR Blaster
Send the raw IR code IR code
i
For a code from somewhere else — another blaster’s "An IR code was learned" token, or one written down earlier. Paste it exactly as it was learned, without the leading format character some tools add.
IR Blaster
Learn an IR code and save it as Name
i
Puts the blaster into learning mode and returns straight away — it does not wait for the button press. Point the remote at the blaster from close up and press once. The code arrives on the "An IR code was learned" trigger and is saved under this name, ready for "Send an IR code".
IR Blaster
Stop learning
i
Leaves learning mode. Worth running once if a blaster stops responding to learn requests: one left in learning mode will not enter it again.
IR Blaster
Forget the IR code Saved code
IR Blaster
Force blaster reconnect
IR Blaster
Refresh blaster values
IR Blaster
Send the IR code named Name
i
The same as "Send an IR code", but with the name typed in rather than picked from a list — a dropdown cannot be filled from a tag, so this is the one to use when the flow works out which button to press. An unknown name fails the card and lists the names this blaster does know.
IR Blaster
Send the IR code Saved codeTimes times, Gap (ms) ms apart
i
For the buttons nobody presses once — volume and channel. The gap is the pause between sends; leave it at 0 and they go out back to back, which some receivers read as one long press and others miss entirely. At most 10 sends a second apart, because the flow waits for the last one.
Light
Activer
Light
Désactiver
Light
Alterner activé ou désactivé
Light
Mettre l'intensité lumineuse sur %
Light
Définir l'intensité lumineuse sur relative %
i
Diminuez ou augmentez la luminosité par rapport au niveau actuel de l'appareil.
Light
Force light reconnect
Light
Refresh light values
Light
Set light colour mode to Mode
i
Switches the lamp between coloured and white light. Homey normally sets this implicitly when a flow changes the colour or the colour temperature; this card changes it on its own. Requires the Colour Mode DP in device settings — the words the lamp itself uses are configurable there too.
Pet Feeder
Feed Portions portion(s) now
Pet Feeder
Force pet feeder reconnect
Pet Feeder
Refresh pet feeder values
Pet Feeder
Set feeder child lock Child lock
Pet Feeder
Set feeder indicator light Indicator light
Pet Feeder
Set feeder voice playback Voice playback
Presence Sensor
Reconnect presence sensor
Presence Sensor
Refresh presence sensor values
Smart Kettle
Activer
Smart Kettle
Désactiver
Smart Kettle
Alterner activé ou désactivé
Smart Kettle
Force kettle reconnect
Smart Kettle
Refresh kettle values
Smart Kettle
Set temperature to Temperature (°C) °C
Smart Kettle
Set mode to Mode
Smart Kettle
Set keep warm to State
Smart Plug
Activer
Smart Plug
Désactiver
Smart Plug
Alterner activé ou désactivé
Smart Plug
Force smart plug reconnect
Smart Plug
Refresh smart plug values
Smart Plug
Set auto-off countdown to Duration (s, 0 = off) s
Smart Plug
Reset energy meter
Smoke Detector
Silence the alarm
i
Silences a sounding detector, where it offers a data point for it. It does not clear the smoke reading — the alarm returns if smoke is still present.
Smoke Detector
Run self-test
i
Starts the detector’s own test. The outcome arrives on the "Self-test finished" trigger and on the Self-Test Failed alarm.
Smoke Detector
Force detector reconnect
Smoke Detector
Refresh detector values
Thermostat
Activer
Thermostat
Désactiver
Thermostat
Alterner activé ou désactivé
Thermostat
Définir la température °C
Thermostat
Force thermostat reconnect
Thermostat
Refresh thermostat values
Thermostat
Set mode to Mode
Thermostat
Set temperature to Temperature (°C) °C
Thermostat
Set thermostat child lock Child lock
Tuya Local
Reconnect Which devices
i
Rebuilds the local connection for every Tuya Local device at once, so one flow covers the whole installation instead of one per device. Useful on a schedule after a router restart. "Offline devices only" leaves working devices untouched and is safe to run repeatedly.
Ultrasonic Level Sensor
Set high threshold to Level (%)%
i
Writes the level above which the device raises its high alarm.
Ultrasonic Level Sensor
Set low threshold to Level (%)%
i
Writes the level below which the device raises its low alarm.
Ultrasonic Level Sensor
Turn the Which alarm level alarm State
Ultrasonic Level Sensor
Force level sensor reconnect
Ultrasonic Level Sensor
Refresh level sensor values
Wall Switch
Activer
Wall Switch
Désactiver
Wall Switch
Alterner activé ou désactivé
Wall Switch
Force wall switch reconnect
Wall Switch
Refresh wall switch values
Wall Switch
Set switch Gang to State
Wall Switch
Toggle switch Gang
Weather Station
Force weather station reconnect
Weather Station
Refresh weather station values
Assistance
Vous avez un problème avec cette appli ?
Contacter le développeur ici.
Nouveautés
Version 1.0.232 — The IR blaster now checks a capture before it keeps it. A weak signal or a tired battery in the remote produces a code that saves perfectly well and never works; that one is turned away with the reason, learning stays on so pressing the button again is enough, and what is kept gets a line in the log describing its shape — how many durations, how long, and which timing classes. That line names the remote without decoding anything: two classes at 1:2 are RC5 or RC6, a long lead-in is NEC. A code that cannot be read is no longer sent either, since the blaster discards it without a word and the flow would report success. And there is a card for the buttons nobody presses once: send a code up to ten times with a gap between. Checked against the device configurations in make-all/tuya-local, which turned up a fault: some of these boxes put a display switch on data point 101, where this app expects a temperature, and a true/false value read as a number would have shown one degree — plausible enough not to notice. Both new drivers now leave a boolean alone and say so once, naming the fix. The settings help gained reference pages for the smoke detector, the air quality monitor and the IR blaster, and the device list behind "Report on GitHub" is complete again — eight drivers were missing from it, so a report about one of them went out without naming the device.