Purpose-built drivers cover the most common Tuya smart home device types — from air conditioners, smart plugs and lights to garage doors, heat pumps and curtain motors. Each driver automatically detects the device's data points at pairing time and maps them to the right Homey capabilities, so most devices are ready to use straight away. A generic driver is included for any device type not covered by the dedicated drivers.
All communication runs directly over your local Wi-Fi network. Devices respond instantly to Homey commands and push state changes in real time, even without an internet connection. Every driver comes with a full set of Flow cards — triggers, conditions and actions — tailored to its device type, so you can build automations the moment your device is added.
Haz clic en el dispositivo de arriba para mostrar solo las tarjetas Flow relacionadas.
Cuando...
Air Conditioner
Encendido
Air Conditioner
Apagado
Air Conditioner
La temperatura deseada ha cambiado
Air Conditioner
La temperatura ha cambiado
Air Conditioner
AC connected
Air Conditioner
AC disconnected
Air Conditioner
AC data point changed
Air Conditioner
AC fault alarm triggered
Air Conditioner
AC mode changed
Air Conditioner
AC child lock was Child lock
Ceiling Fan Light
Encendido
Ceiling Fan Light
Apagado
Ceiling Fan Light
La intensidad de la luz ha cambiado
Ceiling Fan Light
Ceiling fan light connected
Ceiling Fan Light
Ceiling fan light disconnected
Ceiling Fan Light
Fan data point changed
Ceiling Fan Light
Fan mode changed
Ceiling Fan Light
Fan direction changed
Ceiling Fan Light
The fan was Fan
i
Homey supplies the equivalent for the light by itself, because on this driver the light is the fitting’s main switch. The fan has its own switch beside it, and this is the card that watches it.
Ceiling Fan Light
Ceiling fan child lock was Child lock
Ceiling Fan Light
Ceiling fan oscillation was Oscillation
Curtain Motor
El estado ha cambiado ...
Curtain Motor
La posición ha cambiado
Curtain Motor
Cerrados
Curtain Motor
Abiertos
Curtain Motor
Curtain fully opened
Curtain Motor
Curtain fully closed
Curtain Motor
Curtain position changed
Curtain Motor
Curtain motor fault triggered
Curtain Motor
Curtain motor connected
Curtain Motor
Curtain motor disconnected
Curtain Motor
Curtain motor data point changed
Dehumidifier
Encendido
Dehumidifier
Apagado
Dehumidifier
La humedad ha cambiado
Dehumidifier
La velocidad del ventilador ha cambiado
Dehumidifier
La humedad deseada ha cambiado
Dehumidifier
Humidity went above Humidity (%)%
Dehumidifier
Humidity dropped below Humidity (%)%
Dehumidifier
Water tank became full
Dehumidifier
Water tank was emptied
Dehumidifier
Dehumidifier connected
Dehumidifier
Dehumidifier disconnected
Dehumidifier
A data point changed
Dehumidifier
Dehumidifier child lock was Child lock
Dehumidifier
Dehumidifier oscillation was Oscillation
Doorbell
La alarma general se ha activado
Doorbell
La alarma general se ha desactivado
Doorbell
Doorbell rang
Doorbell
Doorbell motion detected
Doorbell
Doorbell connected
Doorbell
Doorbell disconnected
Doorbell
Doorbell data point changed
Energy Meter
La potencia ha cambiado
Energy Meter
La tensión ha cambiado
Energy Meter
La corriente eléctrica ha cambiado
Energy Meter
Energy meter connected
Energy Meter
Energy meter disconnected
Energy Meter
A data point changed
EV Charger
Carga iniciada
EV Charger
Carga detenida
EV Charger
El estado de carga del cargador del VE ha cambiado ...
EV Charger
La potencia objetivo ha cambiado
EV Charger
La potencia ha cambiado
EV Charger
La tensión ha cambiado
EV Charger
La corriente eléctrica ha cambiado
EV Charger
Charger connected
EV Charger
Charger disconnected
EV Charger
Charging session finished
i
Fires when the charger leaves the charging state, with the energy delivered in that session as a token. For a plain start/stop trigger use the built-in "Started charging" / "Stopped charging" cards.
EV Charger
Detailed charger state changed
i
Fires on any change of the charger's raw Tuya state, which is more granular than Homey's standard charging state (it tells "waiting", "finished" and "plugged in" apart).
EV Charger
Charger fault occurred
EV Charger
Charger data point changed
Fan
Encendido
Fan
Apagado
Fan
La intensidad de la luz ha cambiado
Fan
Fan connected
Fan
Fan disconnected
Fan
Fan data point changed
Fan
Fan mode changed
Fan
Fan direction changed
Fan
Fan child lock was Child lock
Fan
Fan oscillation was Oscillation
Garage Door
Cerrados
Garage Door
Abiertos
Garage Door
Garage door opened
Garage Door
Garage door closed
Garage Door
Garage door alarm triggered
Garage Door
Garage door opener connected
Garage Door
Garage door opener disconnected
Garage Door
Garage door data point changed
Generic Tuya Device
A data point changed
Generic Tuya Device
DP DP number changed
i
Fires only when the given DP number changes value. Use the Value / Previous Value tokens in the notification text or a further AND card.
Generic Tuya Device
Device connected
Generic Tuya Device
Device disconnected
Heat Pump
Encendido
Heat Pump
Apagado
Heat Pump
La temperatura deseada ha cambiado
Heat Pump
La temperatura ha cambiado
Heat Pump
Heat pump mode changed
Heat Pump
Heat pump fault alarm triggered
Heat Pump
Heat pump connected
Heat Pump
Heat pump disconnected
Heat Pump
Heat pump data point changed
Heat Pump
Silent mode changed
Heater
Encendido
Heater
Apagado
Heater
La temperatura deseada ha cambiado
Heater
Heater connected
Heater
Heater disconnected
Heater
Heater data point changed
Heater
Heater started heating
Heater
Heater stopped heating
Heater
Heater fault alarm triggered
Heater
Heater child lock was Child lock
Heater
Heater oscillation was Oscillation
Humidifier
Encendido
Humidifier
Apagado
Humidifier
La humedad ha cambiado
Humidifier
La velocidad del ventilador ha cambiado
Humidifier
La humedad deseada ha cambiado
Humidifier
Humidity went above Humidity (%)%
Humidifier
Humidity dropped below Humidity (%)%
Humidifier
Water tank became empty
Humidifier
Water tank was refilled
Humidifier
Humidifier connected
Humidifier
Humidifier disconnected
Humidifier
Humidifier data point changed
Humidifier
Humidifier child lock was Child lock
Light
Encendido
Light
Apagado
Light
La intensidad de la luz ha cambiado
Light
Light connected
Light
Light disconnected
Light
Light data point changed
Pet Feeder
Food level changed
Pet Feeder
Feeding completed
Pet Feeder
Pet feeder connected
Pet Feeder
Pet feeder disconnected
Pet Feeder
Pet feeder data point changed
Pet Feeder
Feeder child lock was Child lock
Presence Sensor
La alarma de movimiento se ha activado
Presence Sensor
La alarma de movimiento se ha desactivado
Presence Sensor
La alarma general se ha activado
Presence Sensor
La alarma general se ha desactivado
Presence Sensor
La distancia ha cambiado
Presence Sensor
La luminancia ha cambiado
Presence Sensor
Presence detected
Presence Sensor
Presence cleared
Presence Sensor
Presence sensor connected
Presence Sensor
Presence sensor disconnected
Presence Sensor
Presence sensor data point changed
Smart Kettle
Encendido
Smart Kettle
Apagado
Smart Kettle
La temperatura ha cambiado
Smart Kettle
Kettle connected
Smart Kettle
Kettle disconnected
Smart Kettle
A data point changed
Smart Kettle
Kettle status changed
Smart Kettle
Kettle finished boiling
Smart Plug
Encendido
Smart Plug
Apagado
Smart Plug
La potencia ha cambiado
Smart Plug
La tensión ha cambiado
Smart Plug
La corriente eléctrica ha cambiado
Smart Plug
El contador de energía ha cambiado
Smart Plug
Smart plug connected
Smart Plug
Smart plug disconnected
Smart Plug
A data point changed
Smart Plug
Power went above Power (W) W
Smart Plug
Power dropped below Power (W) W
Smart Plug
Smart plug fault alarm triggered
Thermostat
Encendido
Thermostat
Apagado
Thermostat
La temperatura deseada ha cambiado
Thermostat
La temperatura ha cambiado
Thermostat
Thermostat connected
Thermostat
Thermostat disconnected
Thermostat
A data point changed
Thermostat
Thermostat mode changed
Thermostat
Thermostat child lock was Child lock
Ultrasonic Level Sensor
Level state changed
Ultrasonic Level Sensor
Level sensor connected
Ultrasonic Level Sensor
Level sensor disconnected
Ultrasonic Level Sensor
Level sensor data point changed
Ultrasonic Level Sensor
Liquid level rose above Level (%)%
Ultrasonic Level Sensor
Liquid level dropped below Level (%)%
Wall Switch
Encendido
Wall Switch
Apagado
Wall Switch
Wall switch connected
Wall Switch
Wall switch disconnected
Wall Switch
A data point changed
Wall Switch
Switch Gang changed
Weather Station
La temperatura ha cambiado
Weather Station
Comfort level changed
Weather Station
Weather station connected
Weather Station
Weather station disconnected
Weather Station
Weather station data point changed
Y...
Air Conditioner
Está encendido
Air Conditioner
AC is connected
Air Conditioner
AC mode is Mode
Air Conditioner
AC fan speed is Fan Speed
Air Conditioner
AC sleep mode is on
Air Conditioner
AC fault alarm is active
Air Conditioner
AC child lock is on
Ceiling Fan Light
Está encendido
Ceiling Fan Light
Ceiling fan light is connected
Ceiling Fan Light
Fan mode is Mode
Ceiling Fan Light
Fan direction is ...
Ceiling Fan Light
Fan is running
Ceiling Fan Light
The fan is oscillating
Ceiling Fan Light
Fan speed is Fan speed
Ceiling Fan Light
The child lock is on
Curtain Motor
El estado es ...
Curtain Motor
Están cerrados
Curtain Motor
Curtain is open (> 50%)
Curtain Motor
Curtain is fully closed
Curtain Motor
Curtain is moving
Curtain Motor
Curtain motor is connected
Dehumidifier
Está encendido
Dehumidifier
Humidity is above Humidity (%)%
Dehumidifier
Humidity is below Humidity (%)%
Dehumidifier
Water tank is full
Dehumidifier
Dehumidifier is connected
Dehumidifier
Mode is Mode
Dehumidifier
Dehumidifier child lock is on
Dehumidifier
Dehumidifier oscillation is on
Doorbell
La alarma general está activada
Doorbell
Doorbell motion is active
Doorbell
Night light is on
Doorbell
Doorbell is connected
Energy Meter
Energy meter is connected
Energy Meter
Power is above Watts W
Energy Meter
Current is above Amps A
i
Useful as an overload warning on a circuit whose breaker rating you know.
Energy Meter
Fault is active
EV Charger
está cargando
EV Charger
El estado de carga del cargador del VE es ...
EV Charger
Charger is connected
EV Charger
Detailed charger state is State
i
Checks the charger's raw Tuya state, which distinguishes "waiting", "finished" and "plugged in" — states that Homey's standard charging state groups together.
Fan
Está encendido
Fan
Fan is connected
Fan
Light is on
Fan
Fan mode is Mode
Fan
Fan direction is ...
Fan
Fan child lock is on
Fan
Fan oscillation is on
Garage Door
Está cerrado
Garage Door
Garage door is open
Garage Door
Garage door opener is connected
Generic Tuya Device
Device is connected
Generic Tuya Device
DP DP number value is Value
i
Compares the last known value of a DP. Value is parsed automatically: 'true'/'false' → boolean, numbers → number, everything else → string.
Heat Pump
Está encendido
Heat Pump
Heat pump is on
Heat Pump
Heat pump fault alarm is active
Heat Pump
Heat pump is connected
Heat Pump
Silent mode is on
Heater
Está encendido
Heater
Heater is connected
Heater
Heater is actively heating
Heater
Heater fault alarm is active
Heater
Heating level is Level
Heater
Heater mode is Mode
Heater
Heater child lock is on
Heater
Heater oscillation is on
Humidifier
Está encendido
Humidifier
Humidifier is connected
Humidifier
Humidity is above Humidity (%)%
Humidifier
Humidity is below Humidity (%)%
Humidifier
Water tank is empty
Humidifier
Humidifier child lock is on
Light
Está encendido
Light
Light is connected
Light
Light colour mode is Mode
Pet Feeder
Food level is low
Pet Feeder
Pet feeder is connected
Pet Feeder
Feeder child lock is on
Presence Sensor
La alarma de movimiento está activada
Presence Sensor
La alarma general está activada
Presence Sensor
Presence is detected
Presence Sensor
Presence sensor is connected
Smart Kettle
Está encendido
Smart Kettle
Kettle is connected
Smart Kettle
Kettle is heating
Smart Plug
Está encendido
Smart Plug
Smart plug is connected
Smart Plug
Fault alarm is active
Smart Plug
Power is above Power (W) W
Thermostat
Está encendido
Thermostat
Thermostat is connected
Thermostat
Mode is Mode
Thermostat
Thermostat child lock is on
Ultrasonic Level Sensor
Level state is State
Ultrasonic Level Sensor
Liquid level is above Level (%)%
Ultrasonic Level Sensor
Level sensor is connected
Wall Switch
Está encendido
Wall Switch
Wall switch is connected
Wall Switch
Switch Gang is on
Weather Station
Comfort level is Comfort
Weather Station
Wind speed is above km/h km/h
Weather Station
Wind is from the Direction
i
Each direction covers a 90° sector, so “north” means anything from north-west round to north-east.
Weather Station
Weather station is connected
Entonces...
Air Conditioner
Encender
Air Conditioner
Apagar
Air Conditioner
Encender o apagar
Air Conditioner
Ajustar la temperatura °C
Air Conditioner
Set AC mode to Mode
Air Conditioner
Set AC fan speed to Fan Speed
Air Conditioner
Set AC target temperature to Temperature (°C) °C
Air Conditioner
Set AC swing to Swing
Air Conditioner
Set AC sleep mode Sleep
Air Conditioner
Set AC ECO mode ECO
Air Conditioner
Set AC ioniser Ioniser
Air Conditioner
Set AC horizontal swing Horizontal swing
Air Conditioner
Set AC child lock Child lock
Air Conditioner
Force AC reconnect
Air Conditioner
Refresh AC device
Air Conditioner
Set AC timer Duration
Ceiling Fan Light
Encender
Ceiling Fan Light
Apagar
Ceiling Fan Light
Encender o apagar
Ceiling Fan Light
Ajustar la intensidad de la luz a %
Ceiling Fan Light
Ajustar la intensidad de la luz como relativa %
i
Atenúa o ilumina con respecto al nivel de atenuación actual del dispositivo.
Ceiling Fan Light
Set fan mode to Mode
Ceiling Fan Light
Set fan speed to Fan Speed
Ceiling Fan Light
Set fan oscillation Oscillate
Ceiling Fan Light
Force ceiling fan light reconnect
Ceiling Fan Light
Refresh ceiling fan light values
Ceiling Fan Light
Set fan direction to ...
Ceiling Fan Light
Set timer to Duration
Ceiling Fan Light
Turn the fan Fan
Ceiling Fan Light
Set fan speed to Speed%
i
For fittings whose speed is a number rather than a named step. The percentage is mapped onto the range in the device settings, so 100% is the fitting’s own highest step — six on most of them. Use “Set fan speed” instead where the fitting names its steps.
Ceiling Fan Light
Set the child lock Child lock
Ceiling Fan Light
Set light mode to Mode
i
Sends a mode token to the light's own mode data point — including scene and music, which the standard light controls cannot express. Requires the Light Mode DP in device settings.
Curtain Motor
Configurar estado ...
Curtain Motor
Configurar la posición como %
i
Cambia la posición a abierto (100 %), cerrado (0 %) o un valor intermedio.
Curtain Motor
Cerrar
Curtain Motor
Abrir
Curtain Motor
Abrir o cerrar
Curtain Motor
Open curtain
Curtain Motor
Close curtain
Curtain Motor
Stop curtain
Curtain Motor
Set curtain position to Position (%)%
Curtain Motor
Move curtain to favourite position
Curtain Motor
Force curtain motor reconnect
Curtain Motor
Refresh curtain motor values
Dehumidifier
Encender
Dehumidifier
Apagar
Dehumidifier
Encender o apagar
Dehumidifier
Ajustar la velocidad del ventilador a %
Dehumidifier
Ajustar la humedad %
Dehumidifier
Set target humidity to Target humidity (%)%
Dehumidifier
Set mode to Mode
Dehumidifier
Set fan speed to Fan Speed
Dehumidifier
Set timer to Duration
Dehumidifier
Set child lock Child Lock
Dehumidifier
Set ioniser Ioniser
Dehumidifier
Set dehumidifier oscillation Oscillate
Dehumidifier
Set self-clean Self-Clean
Dehumidifier
Set water pump Water Pump
Dehumidifier
Force dehumidifier reconnect
Dehumidifier
Refresh dehumidifier values
Doorbell
Enable motion detection
Doorbell
Disable motion detection
Doorbell
Force doorbell reconnect
Doorbell
Refresh doorbell values
Doorbell
Set night vision to Mode
Doorbell
Set chime volume to Volume (0–100)
Doorbell
Turn night light State
Doorbell
Turn alarm reporting State
Doorbell
Set ring tone to Melody number
Doorbell
Set motion sensitivity to Sensitivity
Energy Meter
Force energy meter reconnect
Energy Meter
Refresh energy meter values
EV Charger
Iniciar carga
EV Charger
Detener carga
EV Charger
Establecer la potencia objetivo W
i
Esto también cambia el modo de potencia objetivo a Homey. En el caso de cargadores de vehículos eléctricos, la carga se inicia o detiene automáticamente.
EV Charger
Set charge current to Current A
i
Clamped to the Current Min / Current Max range configured in device settings.
EV Charger
Reset energy meter
EV Charger
Force charger reconnect
EV Charger
Refresh charger values
Fan
Encender
Fan
Apagar
Fan
Encender o apagar
Fan
Ajustar la intensidad de la luz a %
Fan
Ajustar la intensidad de la luz como relativa %
i
Atenúa o ilumina con respecto al nivel de atenuación actual del dispositivo.
Fan
Set fan mode to Mode
Fan
Set fan speed to Fan Speed
Fan
Set fan oscillation Oscillate
Fan
Force fan reconnect
Fan
Refresh fan values
Fan
Set fan direction to ...
Fan
Set timer to Duration
Fan
Turn light Light
Fan
Set light brightness to Brightness%
Fan
Set light mode to Mode
i
Sends a mode token to the light's own mode data point — including scene and music, which the standard light controls cannot express. Requires the Light Mode DP in device settings.
Fan
Set fan child lock Child lock
Garage Door
Cerrar
Garage Door
Abrir
Garage Door
Abrir o cerrar
Garage Door
Open garage door
Garage Door
Close garage door
Garage Door
Toggle garage door
Garage Door
Stop garage door
Garage Door
Force garage door opener reconnect
Garage Door
Refresh garage door values
Generic Tuya Device
Force reconnect
Generic Tuya Device
Refresh device values
Generic Tuya Device
Set DP DP number to Value
i
Send a raw data point (DP) command. Value is parsed automatically: 'true'/'false' → boolean, numbers → integer/float, everything else → string.
Heat Pump
Encender
Heat Pump
Apagar
Heat Pump
Encender o apagar
Heat Pump
Ajustar la temperatura °C
Heat Pump
Set heat pump mode to Mode
Heat Pump
Set heat pump preset to Preset
Heat Pump
Force heat pump reconnect
Heat Pump
Refresh heat pump values
Heat Pump
Turn silent mode ...
Heater
Encender
Heater
Apagar
Heater
Encender o apagar
Heater
Ajustar la temperatura °C
Heater
Set heater mode to Mode
Heater
Set heater target temperature to Temperature (°C) °C
Heater
Set heating level to Level
i
The heating power step. These heaters offer named steps rather than a percentage, so the choices come from what your device declares.
Heater
Set heater oscillation Oscillate
Heater
Set heater child lock Child lock
Heater
Force heater reconnect
Heater
Refresh heater values
Heater
Set heater timer Duration
Humidifier
Encender
Humidifier
Apagar
Humidifier
Encender o apagar
Humidifier
Ajustar la velocidad del ventilador a %
Humidifier
Ajustar la humedad %
Humidifier
Set target humidity to Target humidity (%)%
Humidifier
Set humidifier mode to Mode
Humidifier
Set humidifier fan speed to Fan Speed
Humidifier
Force humidifier reconnect
Humidifier
Refresh humidifier values
Humidifier
Set humidifier ioniser Ioniser
Humidifier
Set humidifier child lock Child lock
Humidifier
Set humidifier timer Duration
Light
Encender
Light
Apagar
Light
Encender o apagar
Light
Ajustar la intensidad de la luz a %
Light
Ajustar la intensidad de la luz como relativa %
i
Atenúa o ilumina con respecto al nivel de atenuación actual del dispositivo.
Light
Force light reconnect
Light
Refresh light values
Light
Set light colour mode to Mode
i
Switches the lamp between coloured and white light. Homey normally sets this implicitly when a flow changes the colour or the colour temperature; this card changes it on its own. Requires the Colour Mode DP in device settings — the words the lamp itself uses are configurable there too.
Pet Feeder
Feed Portions portion(s) now
Pet Feeder
Force pet feeder reconnect
Pet Feeder
Refresh pet feeder values
Pet Feeder
Set feeder child lock Child lock
Pet Feeder
Set feeder indicator light Indicator light
Pet Feeder
Set feeder voice playback Voice playback
Presence Sensor
Reconnect presence sensor
Presence Sensor
Refresh presence sensor values
Smart Kettle
Encender
Smart Kettle
Apagar
Smart Kettle
Encender o apagar
Smart Kettle
Force kettle reconnect
Smart Kettle
Refresh kettle values
Smart Kettle
Set temperature to Temperature (°C) °C
Smart Kettle
Set mode to Mode
Smart Kettle
Set keep warm to State
Smart Plug
Encender
Smart Plug
Apagar
Smart Plug
Encender o apagar
Smart Plug
Force smart plug reconnect
Smart Plug
Refresh smart plug values
Smart Plug
Set auto-off countdown to Duration (s, 0 = off) s
Smart Plug
Reset energy meter
Thermostat
Encender
Thermostat
Apagar
Thermostat
Encender o apagar
Thermostat
Ajustar la temperatura °C
Thermostat
Force thermostat reconnect
Thermostat
Refresh thermostat values
Thermostat
Set mode to Mode
Thermostat
Set temperature to Temperature (°C) °C
Thermostat
Set thermostat child lock Child lock
Tuya Local
Reconnect Which devices
i
Rebuilds the local connection for every Tuya Local device at once, so one flow covers the whole installation instead of one per device. Useful on a schedule after a router restart. "Offline devices only" leaves working devices untouched and is safe to run repeatedly.
Ultrasonic Level Sensor
Set high threshold to Level (%)%
i
Writes the level above which the device raises its high alarm.
Ultrasonic Level Sensor
Set low threshold to Level (%)%
i
Writes the level below which the device raises its low alarm.
Ultrasonic Level Sensor
Turn the Which alarm level alarm State
Ultrasonic Level Sensor
Force level sensor reconnect
Ultrasonic Level Sensor
Refresh level sensor values
Wall Switch
Encender
Wall Switch
Apagar
Wall Switch
Encender o apagar
Wall Switch
Force wall switch reconnect
Wall Switch
Refresh wall switch values
Wall Switch
Set switch Gang to State
Wall Switch
Toggle switch Gang
Weather Station
Force weather station reconnect
Weather Station
Refresh weather station values
Asistencia
¿Tienes algún problema con esta aplicación?
Contacta con el desarrollador aquí.
Novedades
Versión 1.0.225 — Fixed: with "Main switch controls all channels" enabled, the flow cards that take a channel number reached the aggregate instead of physical channel 1, so a flow naming channel 1 switched both. The device knew where channel 1 had moved to; the three flow cards worked it out for themselves and did not. They now ask the device.