ID Lock Next

Modern control for ID Lock smart locks over Z-Wave and Zigbee.

Warning! This app might not work properly.

This app version is currently being tested, and has not yet been reviewed. It might not work as expected.
Be extra careful when installing this app.

« Back to the regular version

Modern control for ID Lock smart locks over Z-Wave and Zigbee.

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

ID Lock 101 (Z-Wave)
Locked
ID Lock 101 (Z-Wave)
Unlocked
ID Lock 101 (Z-Wave)
The contact alarm turned on
ID Lock 101 (Z-Wave)
The contact alarm turned off
ID Lock 101 (Z-Wave)
The battery level changed
ID Lock 101 (Z-Wave)
The battery alarm turned on
ID Lock 101 (Z-Wave)
The battery alarm turned off
ID Lock 101 (Z-Wave)
The tamper alarm turned on
ID Lock 101 (Z-Wave)
The tamper alarm turned off
ID Lock 101 (Z-Wave)
The heat alarm turned on
ID Lock 101 (Z-Wave)
The heat alarm turned off
ID Lock 101 (Z-Wave)
Away mode was turned State
i
Fires when away mode turns on or off — from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 101 (Z-Wave)
A PIN code failed to sync
i
Fires when a user's PIN code could not be written to the lock — for example when the lock rejects it as a duplicate of a code already stored (such as one programmed at the keypad), or when the lock does not respond. The reason tag says why.
ID Lock 101 (Z-Wave)
The door has been left open
i
Fires when the door stays open longer than the 'Door-open alert' time set in the device's advanced settings.
ID Lock 101 (Z-Wave)
The lock jammed
i
Fires when the lock motor reports that it could not lock or unlock.
ID Lock 101 (Z-Wave)
User Action the door with Type
i
Fires when the door is locked or unlocked by the user you pick — handy for knowing exactly who locked up or came home.
ID Lock 101 (Z-Wave)
The door was State
i
Fires when the door is locked or unlocked. Choose which state to react to, or either.
ID Lock 101 (Z-Wave)
The service PIN expired
i
Fires when the temporary service PIN stops being valid — its uses ran out or its time window ended.
ID Lock 101 (Z-Wave)
Too many wrong codes were entered
i
Fires when the lock temporarily disables its keypad after repeated wrong PIN attempts — a possible break-in attempt. Z-Wave only.
ID Lock 150 / 202 (Z-Wave)
Locked
ID Lock 150 / 202 (Z-Wave)
Unlocked
ID Lock 150 / 202 (Z-Wave)
The contact alarm turned on
ID Lock 150 / 202 (Z-Wave)
The contact alarm turned off
ID Lock 150 / 202 (Z-Wave)
The battery level changed
ID Lock 150 / 202 (Z-Wave)
The battery alarm turned on
ID Lock 150 / 202 (Z-Wave)
The battery alarm turned off
ID Lock 150 / 202 (Z-Wave)
The tamper alarm turned on
ID Lock 150 / 202 (Z-Wave)
The tamper alarm turned off
ID Lock 150 / 202 (Z-Wave)
The heat alarm turned on
ID Lock 150 / 202 (Z-Wave)
The heat alarm turned off
ID Lock 150 / 202 (Z-Wave)
Away mode was turned State
i
Fires when away mode turns on or off — from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 150 / 202 (Z-Wave)
A PIN code failed to sync
i
Fires when a user's PIN code could not be written to the lock — for example when the lock rejects it as a duplicate of a code already stored (such as one programmed at the keypad), or when the lock does not respond. The reason tag says why.
ID Lock 150 / 202 (Z-Wave)
The door has been left open
i
Fires when the door stays open longer than the 'Door-open alert' time set in the device's advanced settings.
ID Lock 150 / 202 (Z-Wave)
The lock jammed
i
Fires when the lock motor reports that it could not lock or unlock.
ID Lock 150 / 202 (Z-Wave)
User Action the door with Type
i
Fires when the door is locked or unlocked by the user you pick — handy for knowing exactly who locked up or came home.
ID Lock 150 / 202 (Z-Wave)
The door was State
i
Fires when the door is locked or unlocked. Choose which state to react to, or either.
ID Lock 150 / 202 (Z-Wave)
The service PIN expired
i
Fires when the temporary service PIN stops being valid — its uses ran out or its time window ended.
ID Lock 150 / 202 (Z-Wave)
Too many wrong codes were entered
i
Fires when the lock temporarily disables its keypad after repeated wrong PIN attempts — a possible break-in attempt. Z-Wave only.
ID Lock 150 / 202 (Zigbee)
Locked
ID Lock 150 / 202 (Zigbee)
Unlocked
ID Lock 150 / 202 (Zigbee)
The contact alarm turned on
ID Lock 150 / 202 (Zigbee)
The contact alarm turned off
ID Lock 150 / 202 (Zigbee)
The battery level changed
ID Lock 150 / 202 (Zigbee)
The battery alarm turned on
ID Lock 150 / 202 (Zigbee)
The battery alarm turned off
ID Lock 150 / 202 (Zigbee)
The tamper alarm turned on
ID Lock 150 / 202 (Zigbee)
The tamper alarm turned off
ID Lock 150 / 202 (Zigbee)
Away mode was turned State
i
Fires when away mode turns on or off — from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 150 / 202 (Zigbee)
A PIN code failed to sync
i
Fires when a user's PIN code could not be written to the lock — for example when the lock rejects it as a duplicate of a code already stored (such as one programmed at the keypad), or when the lock does not respond. The reason tag says why.
ID Lock 150 / 202 (Zigbee)
The door was forced open
i
Fires when the lock reports the door was opened without unlocking (forced open). Zigbee locks only.
ID Lock 150 / 202 (Zigbee)
The door has been left open
i
Fires when the door stays open longer than the 'Door-open alert' time set in the device's advanced settings.
ID Lock 150 / 202 (Zigbee)
The lock jammed
i
Fires when the lock motor reports that it could not lock or unlock.
ID Lock 150 / 202 (Zigbee)
User Action the door with Type
i
Fires when the door is locked or unlocked by the user you pick — handy for knowing exactly who locked up or came home.
ID Lock 150 / 202 (Zigbee)
The door was State
i
Fires when the door is locked or unlocked. Choose which state to react to, or either.

And...

ID Lock 101 (Z-Wave)
A lock is locked
ID Lock 101 (Z-Wave)
The contact alarm is on
ID Lock 101 (Z-Wave)
The battery alarm is on
ID Lock 101 (Z-Wave)
The tamper alarm is on
ID Lock 101 (Z-Wave)
The heat alarm is on
ID Lock 101 (Z-Wave)
Away mode is on
i
True while the lock is in away mode. Stays in sync when the mode is changed from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 101 (Z-Wave)
Battery is below 20%
i
True while the lock's battery is below the percentage you set.
ID Lock 101 (Z-Wave)
User was the last to Action the door with Type
i
True if the door's most recent lock or unlock was done by this user — optionally with a specific method.
ID Lock 101 (Z-Wave)
has a PIN code for Name
i
True if a user with this name currently has a PIN code on the lock.
ID Lock 150 / 202 (Z-Wave)
A lock is locked
ID Lock 150 / 202 (Z-Wave)
The contact alarm is on
ID Lock 150 / 202 (Z-Wave)
The battery alarm is on
ID Lock 150 / 202 (Z-Wave)
The tamper alarm is on
ID Lock 150 / 202 (Z-Wave)
The heat alarm is on
ID Lock 150 / 202 (Z-Wave)
Away mode is on
i
True while the lock is in away mode. Stays in sync when the mode is changed from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 150 / 202 (Z-Wave)
Battery is below 20%
i
True while the lock's battery is below the percentage you set.
ID Lock 150 / 202 (Z-Wave)
User was the last to Action the door with Type
i
True if the door's most recent lock or unlock was done by this user — optionally with a specific method.
ID Lock 150 / 202 (Z-Wave)
has a PIN code for Name
i
True if a user with this name currently has a PIN code on the lock.
ID Lock 150 / 202 (Zigbee)
A lock is locked
ID Lock 150 / 202 (Zigbee)
The contact alarm is on
ID Lock 150 / 202 (Zigbee)
The battery alarm is on
ID Lock 150 / 202 (Zigbee)
The tamper alarm is on
ID Lock 150 / 202 (Zigbee)
Away mode is on
i
True while the lock is in away mode. Stays in sync when the mode is changed from the keypad (code + *), the app, a Flow or the settings page.
ID Lock 150 / 202 (Zigbee)
Battery is below 20%
i
True while the lock's battery is below the percentage you set.
ID Lock 150 / 202 (Zigbee)
User was the last to Action the door with Type
i
True if the door's most recent lock or unlock was done by this user — optionally with a specific method.
ID Lock 150 / 202 (Zigbee)
has a PIN code for Name
i
True if a user with this name currently has a PIN code on the lock.

Then...

ID Lock 101 (Z-Wave)
Lock
ID Lock 101 (Z-Wave)
Unlock
ID Lock 101 (Z-Wave)
Refresh state from the lock
i
Asks the lock for its current lock/door state (and battery). Useful if Homey looks out of sync.
ID Lock 101 (Z-Wave)
Turn auto-lock On/off
i
Whether the lock locks itself automatically. The away-mode setting is left unchanged.
ID Lock 101 (Z-Wave)
Set the lock to Mode
i
Switch the lock between Home and Away mode. The auto-lock setting is left unchanged.
ID Lock 101 (Z-Wave)
Set the service PIN to New service PIN, Validity
i
The service PIN must be 4-10 digits. Anyone who can edit this Flow can see the code — and anyone with the code can open the door while it is valid. The lock erases the service PIN when its batteries are removed.
ID Lock 101 (Z-Wave)
Set the service PIN validity to Validity
i
Changes how long or how many times the current service PIN stays valid — the code itself is unchanged. Options with a random PIN or always valid require lock firmware 1.6 or newer.
ID Lock 150 / 202 (Z-Wave)
Lock
ID Lock 150 / 202 (Z-Wave)
Unlock
ID Lock 150 / 202 (Z-Wave)
Refresh state from the lock
i
Asks the lock for its current lock/door state (and battery). Useful if Homey looks out of sync.
ID Lock 150 / 202 (Z-Wave)
Turn auto-lock On/off
i
Whether the lock locks itself automatically. The away-mode setting is left unchanged.
ID Lock 150 / 202 (Z-Wave)
Set the lock to Mode
i
Switch the lock between Home and Away mode. The auto-lock setting is left unchanged.
ID Lock 150 / 202 (Z-Wave)
Set the service PIN to New service PIN, Validity
i
The service PIN must be 4-10 digits. Anyone who can edit this Flow can see the code — and anyone with the code can open the door while it is valid. The lock erases the service PIN when its batteries are removed.
ID Lock 150 / 202 (Z-Wave)
Set the service PIN validity to Validity
i
Changes how long or how many times the current service PIN stays valid — the code itself is unchanged. Options with a random PIN or always valid require lock firmware 1.6 or newer.
ID Lock 150 / 202 (Zigbee)
Lock
ID Lock 150 / 202 (Zigbee)
Unlock
ID Lock 150 / 202 (Zigbee)
Refresh state from the lock
i
Asks the lock for its current lock/door state (and battery). Useful if Homey looks out of sync.
ID Lock 150 / 202 (Zigbee)
Turn auto-lock On/off
i
Whether the lock locks itself automatically. The away-mode setting is left unchanged.
ID Lock 150 / 202 (Zigbee)
Set the lock to Mode
i
Switch the lock between Home and Away mode. The auto-lock setting is left unchanged.
ID Lock 150 / 202 (Zigbee)
Set the service PIN to New service PIN, Validity
i
The service PIN must be 4-10 digits. Anyone who can edit this Flow can see the code — and anyone with the code can open the door while it is valid. The lock erases the service PIN when its batteries are removed.
ID Lock 150 / 202 (Zigbee)
Set the service PIN validity to Validity
i
Changes how long or how many times the current service PIN stays valid — the code itself is unchanged. Options with a random PIN or always valid require lock firmware 1.6 or newer.

Support

Having an issue with this app? Contact the developer via the Homey Community Forum.

What’s new

Version 2.6.4 — Fix: after deleting a user, the code check no longer claims an unknown code is still stored in that slot — confirmed code writes and deletes now update the last scan result immediately.

View changelog

ID Lock Next

ID Lock Next is not compatible with the selected Homey.

ID Lock Next will install on Homey shortly.
Install App