Samsung's newer appliances speak a local protocol on your own network, and this app speaks it back. Commands and readings go straight to the appliance's address on your LAN instead of out through SmartThings, so nothing about your home leaves it, and everything keeps working when the internet does not.
Air conditioners, induction cooktops, range hoods and refrigerators are supported, each verified against real hardware — a hood's fan and light, a fridge's temperature per compartment including a convertible one it tells you is currently cooling or freezing, an air conditioner's temperature, mode and comfort settings. All of it is available to a Flow: anything the appliance reports can be a condition, anything it accepts can be an action. Heat control is the one deliberate exception, read-only on cooking appliances, because an automation must never start a burner. Setup is installing it: the app issues its own client certificate on first run, then finds your appliances by searching the network. You can supply your own certificate instead, and the app will never replace it. Roughly 2022 and later models expose the local protocol; older ones keep no local port open and cannot be reached this way.
Læs mere ›
Flow-kort
Klik på en enhed ovenfor for kun at vise relaterede Flow-kort.
Når...
Samsung Appliance
An alarm was raised
Samsung Appliance
Dust bag needs attention cleared
Samsung Appliance
Dust bag needs attention was raised
Samsung Appliance
The filter is back to normal
Samsung Appliance
A filter needs attention
Samsung Appliance
Hot surface cleared
Samsung Appliance
Hot surface was raised
Samsung Appliance
A burner is on turned off
Samsung Appliance
A burner is on turned on
Samsung Appliance
A cycle finished
Samsung Appliance
A cycle started
Samsung Appliance
The light turned off
Samsung Appliance
The light turned on
Samsung Appliance
Firmware update available turned off
Samsung Appliance
Firmware update available turned on
Samsung Appliance
Machine state changed
Samsung Appliance
Status changed
Samsung Appliance
Probe connected turned off
Samsung Appliance
Probe connected turned on
Samsung Appliance
Progress changed
Samsung Appliance
Time remaining changed
Samsung Appliance
Safety auto-shutoff turned off
Samsung Appliance
Safety auto-shutoff turned on
Samsung Appliance
Self check changed
Og...
Samsung Appliance
Absence clean is on
Samsung Appliance
Absence detection is on
Samsung Appliance
Absence threshold is at least ... min
Samsung Appliance
Motion monitoring is on
Samsung Appliance
Absence power saving is on
Samsung Appliance
Mode is ...
Samsung Appliance
Air purify is on
Samsung Appliance
Air cleanliness is at least ...
Samsung Appliance
Action on sensing is ...
Samsung Appliance
Periodic air sensing is on
Samsung Appliance
Last air grade is ...
Samsung Appliance
Sensing is ...
Samsung Appliance
Active alarm is ...
Samsung Appliance
Dust bag needs attention is on
Samsung Appliance
Filter needs attention is on
Samsung Appliance
Hot surface is on
Samsung Appliance
Auto dry running is on
Samsung Appliance
Auto clean is on
Samsung Appliance
Auto dry progress is at least ... %
Samsung Appliance
Auto close is on
Samsung Appliance
Auto empty is on
Samsung Appliance
Automatic ventilation is on
Samsung Appliance
Auto fill is on
Samsung Appliance
A burner is on is on
Samsung Appliance
Burner level is ...
Samsung Appliance
Burner state is ...
Samsung Appliance
Interior light is on
Samsung Appliance
Child lock is on
Samsung Appliance
Child lock is on
Samsung Appliance
Convenient mode is ...
Samsung Appliance
Convertible compartment is ...
Samsung Appliance
Cycle running is on
Samsung Appliance
Dry level is ...
Samsung Appliance
Dust PM1.0 is at least ... µg/m³
Samsung Appliance
Dust PM10 is at least ... µg/m³
Samsung Appliance
Dust bag usage is at least ...
Samsung Appliance
Edge lighting colour is ...
Samsung Appliance
Edge lighting is on
Samsung Appliance
Edge lighting brightness is ...
Samsung Appliance
Fan speed is ...
Samsung Appliance
Fan level is at least ...
Samsung Appliance
Filter usage is at least ... %
Samsung Appliance
Firmware update available is on
Samsung Appliance
Heated dry is ...
Samsung Appliance
Fan speed is at least ...
Samsung Appliance
Ice maker is on
Samsung Appliance
State is arriving by push
Samsung Appliance
Storage mode is ...
Samsung Appliance
Racks is at least ...
Samsung Appliance
Ripening is ...
Samsung Appliance
Ripening remaining is at least ...
Samsung Appliance
Light brightness is at least ...
Samsung Appliance
The light is on
Samsung Appliance
Panel brightness is ...
Samsung Appliance
Machine state is ...
Samsung Appliance
Avoid direct wind is on
Samsung Appliance
Mute beep once is on
Samsung Appliance
Smart Cool Clean is on
Samsung Appliance
Smart Cool Clean progress is at least ... %
Samsung Appliance
Operation state code is at least ...
Samsung Appliance
Status is ...
Samsung Appliance
Oven mode is ...
Samsung Appliance
Pan is on
Samsung Appliance
Pet filter is on
Samsung Appliance
Power saving level is ...
Samsung Appliance
Power is on
Samsung Appliance
Probe connected is on
Samsung Appliance
Progress is at least ... %
Samsung Appliance
Rapid freezing is on
Samsung Appliance
Rapid cooling is on
Samsung Appliance
Time remaining is at least ... min
Samsung Appliance
Rinse cycles is at least ...
Samsung Appliance
Sabbath mode is on
Samsung Appliance
Safety auto-shutoff is on
Samsung Appliance
Sanitize is on
Samsung Appliance
Self check running is on
Samsung Appliance
Self check is ...
Samsung Appliance
Self check progress is at least ... %
Samsung Appliance
Smart control enabled is on
Samsung Appliance
Smart sensing cooling is on
Samsung Appliance
Sound mode is ...
Samsung Appliance
Sound volume is at least ...
Samsung Appliance
Spin speed is ...
Samsung Appliance
Target humidity is at least ... %
Samsung Appliance
Set temperature is at least ... °C
Samsung Appliance
UV sterilisation is on
Samsung Appliance
Wash temperature is ...
Samsung Appliance
Water used is at least ... L
Samsung Appliance
Water tank alarm is ...
Samsung Appliance
Water tank light is on
Samsung Appliance
Welcome lighting is on
Samsung Appliance
Airflow direction is ...
Samsung Appliance
Airflow toward people is ...
Samsung Appliance
Wrinkle prevention is on
Så...
Samsung Appliance
Turn Absence clean ...
Samsung Appliance
Turn Absence power saving ...
Samsung Appliance
Set Mode to ...
Samsung Appliance
Apply settings: power Power, mode Mode, Target temperature (0 to skip)°C, fan Fan speed, direction Airflow direction, air purify Air purify, comfort Comfort mode
Samsung Appliance
Turn Air purify ...
Samsung Appliance
Turn Auto clean ...
Samsung Appliance
Turn Auto close ...
Samsung Appliance
Turn Auto empty ...
Samsung Appliance
Turn Auto fill ...
Samsung Appliance
Turn Interior light ...
Samsung Appliance
Turn Child lock ...
Samsung Appliance
Set Convenient mode to ...
Samsung Appliance
Turn Edge lighting ...
Samsung Appliance
Set Edge lighting colour to ...
Samsung Appliance
Set Edge lighting brightness to ...
Samsung Appliance
Set Fan speed to ...
Samsung Appliance
Set Fan speed to ...
Samsung Appliance
Turn Ice maker ...
Samsung Appliance
Set Storage mode to ...
Samsung Appliance
Set Light brightness to ...
Samsung Appliance
Turn the light ...
Samsung Appliance
Turn Avoid direct wind ...
Samsung Appliance
Turn Mute beep once ...
Samsung Appliance
Turn Pet filter ...
Samsung Appliance
Turn Rapid freezing ...
Samsung Appliance
Turn Rapid cooling ...
Samsung Appliance
Turn Sabbath mode ...
Samsung Appliance
Turn Sanitize ...
Samsung Appliance
Turn Smart sensing cooling ...
Samsung Appliance
Set Target humidity to ...
Samsung Appliance
Turn UV sterilisation ...
Samsung Appliance
Turn Water tank light ...
Samsung Appliance
Turn Welcome lighting ...
Samsung Appliance
Set Airflow direction to ...
Samsung Appliance
Turn Wrinkle prevention ...
Support
Har du et problem med denne app?
Kontakt udvikleren her.
Hvad er nyt
Version 1.0.7 — Kimchi refrigerators now report each compartment: its storage mode, the ripening status and time remaining, and how many racks it holds. Both layouts are covered — the one-door units and the three-drawer ones, which keep a separate mode per drawer. The mode can be set, and each compartment offers only the modes that compartment itself reports supporting, which is not the same list on every drawer. These units were already recognised as refrigerators, but until now almost nothing inside them could be read.
Air conditioners with an edge light can now set its brightness and its colour temperature, not just switch it on and off. Both were confirmed by writing to the appliances here and reading the values back, and both offer only what the unit itself reports it supports.
Air conditioners read and offer more comfort modes. Quiet in particular is on most boards and was simply missing, so a unit sitting in it showed nothing and could not be put back into it; Smart, the two motion modes and dry comfort are added alongside it.
Three reliability fixes. Setting a comfort mode right after switching an air conditioner on used to fail the whole Flow card: the unit refuses for a few seconds while it starts up, and nothing it reports says so, so the card now waits and asks again instead of giving up on the first refusal. A command sent just as the appliance closed the connection was lost with nothing but an error; it is now retried once on a fresh connection, which is what reading has always done. And an appliance that goes off the network — switched off at the breaker, or Wi-Fi down — no longer keeps reporting that it is sending live updates; its settings and the matching Flow condition now say it is being polled, and it returns to live updates by itself once it is reachable again.
Air conditioners now report an operation state code the appliance keeps beside its error and filter alarms, with its history graphed in Insights. It reads 0 whenever the unit is off and a number whenever it is running, with no exception across eight hours of samples from four units. It is not a fault: the appliance's own error channel reports no error throughout, which is why Samsung's own app calls the same unit healthy. What the number means is not settled yet, so the reading is named for what it is rather than for a guess at what it tracks.
Se ændringslog