Local access to the Aurora series heat pump device.
Setup:
To find out the local key to use, refer to the GitHub source: /docs/Get Local Keys - instruction.pdf
Usage:
See the file: /docs/Flow Card handling/flow-cards-overview.md for instructions on how to use the flow cards in your Advanced Flow.
For an overview of the Capabilities, see: /docs/Heatpump specs/capabilities-overview.md
For information about the mapping between Capabilities and Flow Cards, see: /docs/Flow Card handling/capability-flowcard-mapping.md
Läs mer ›
Flow-kort
Klicka på en enhet ovan för att visa endast relaterade Flow-kort.
När...
intelligent-heat-pump
Måltemperaturen ändrades
intelligent-heat-pump
Aktiverad
intelligent-heat-pump
Inaktiverad
intelligent-heat-pump
Vattenflödet ändrades
intelligent-heat-pump
Strömmen ändrades
intelligent-heat-pump
Ambient temperature Condition Temperature (°C)°C
intelligent-heat-pump
Backwater turned State
intelligent-heat-pump
Coiler temperature Condition Temperature (°C)°C
intelligent-heat-pump
Compressor frequency Condition Frequency (Hz) Hz
intelligent-heat-pump
Compressor turned State
intelligent-heat-pump
Countdown timer finished
intelligent-heat-pump
Daily consumption reached Daily threshold (kWh) kWh
intelligent-heat-pump
Defrost turned State
intelligent-heat-pump
Discharge temperature Condition Temperature (°C)°C
intelligent-heat-pump
Economizer inlet temperature Condition Temperature (°C)°C
intelligent-heat-pump
Economizer outlet temperature Condition Temperature (°C)°C
intelligent-heat-pump
EEV pulse-steps Condition Pulse-steps
intelligent-heat-pump
Current load Condition Current (A) amperes
intelligent-heat-pump
EVI Open pulse-steps Condition Pulse-steps
intelligent-heat-pump
Fan motor frequency Condition Frequency (Hz) Hz
intelligent-heat-pump
Fault code Fault code detected
intelligent-heat-pump
High pressure temperature Condition Temperature (°C)°C
intelligent-heat-pump
Incoiler temperature Condition Temperature (°C)°C
intelligent-heat-pump
Inlet temperature Condition Temperature (°C)°C
intelligent-heat-pump
Low pressure temperature Condition Temperature (°C)°C
intelligent-heat-pump
Outlet temperature Condition Temperature (°C)°C
intelligent-heat-pump
Phase A voltage Condition Voltage (V) volts
intelligent-heat-pump
Phase B current Condition Current (A) amperes
intelligent-heat-pump
Phase B voltage Condition Voltage (V) volts
intelligent-heat-pump
Phase C current Condition Current (A) amperes
intelligent-heat-pump
Phase C voltage Condition Voltage (V) volts
intelligent-heat-pump
Power consumption exceeded Power threshold (W) W
intelligent-heat-pump
Suction temperature Condition Temperature (°C)°C
intelligent-heat-pump
Tank temperature Condition Temperature (°C)°C
intelligent-heat-pump
Total consumption reached Consumption milestone (kWh) kWh
intelligent-heat-pump
Water flow rate Condition Flow rate (L/min) L/min
Och...
intelligent-heat-pump
Är på
intelligent-heat-pump
Hot water curve setting is Hot water curve setting
intelligent-heat-pump
Compressor is running
intelligent-heat-pump
Device power is Power state
intelligent-heat-pump
3-phase electrical balance is within Balance tolerance (%)% tolerance
intelligent-heat-pump
Fault is active
intelligent-heat-pump
Heating curve setting is Heating curve
intelligent-heat-pump
Heating mode is Heating mode
intelligent-heat-pump
Hot water temperature is Comparison Hot water temperature (°C)°C
intelligent-heat-pump
Power consumption is above Power threshold (W) watts
intelligent-heat-pump
System pulse-steps differential is above Pulse-steps differential
intelligent-heat-pump
Target temperature is Comparison Temperature (°C)°C
intelligent-heat-pump
Ambient temperature is above Temperature°C
intelligent-heat-pump
Temperature differential is above Temperature differential (°C)°C
intelligent-heat-pump
Total consumption is above Consumption threshold (kWh) kWh
intelligent-heat-pump
Electricity consumption checking is Comparison Electricity consumption checking
intelligent-heat-pump
Water flow rate is above Flow rate (L/min) L/min
intelligent-heat-pump
Water control mode is Comparison Water control mode
intelligent-heat-pump
Work mode is Work mode
Då...
intelligent-heat-pump
Ställ in temperaturen °C
intelligent-heat-pump
Aktivera
intelligent-heat-pump
Stäng av
intelligent-heat-pump
Växla på och av
intelligent-heat-pump
Set hot water curve setting to Hot water curve setting
intelligent-heat-pump
Set device power to Power state
intelligent-heat-pump
Set heating curve setting to Heating curve setting
intelligent-heat-pump
Set heating mode to Heating mode
intelligent-heat-pump
Set hot water temperature to Hot water temperature (°C)
intelligent-heat-pump
Set target temperature to Temperature (°C)
intelligent-heat-pump
Set electricity consumption checking to Electricity consumption checking
intelligent-heat-pump
Set water control mode to Water control mode
intelligent-heat-pump
Set work mode to Work mode
Vad är nytt?