My home. My energy. Our climate.

Czytaj więcej ›

Obsługiwane urządzenia

Karty Flow

Kliknij na urządzenie powyżej, aby wyświetlić tylko powiązane karty Flow.

Kiedy...

Battery
Zmienił się poziom baterii
Battery
Zmiana mocy
Battery
Zmiana poziomu napięcia
Battery
Zmiana prądu elektrycznego
Battery
Stan ładowania baterii uległ zmianie ...
Battery
Zmiana temperatury
Energy Meter
Zmiana mocy
Energy Meter
Zmiana w liczniku mocy
Energy Meter
Phase [[phase]] is utilized to [[percentageUtilized]]%
Energy summary
Zmiana mocy
Energy summary
Zmiana w liczniku mocy
Inverter
Moc docelowa uległa zmianie
Inverter
Zmiana mocy
Inverter
Zmiana poziomu napięcia
Inverter
Zmiana w liczniku mocy
Inverter
Condition changed to [[inverter_condition]]
Inverter
Operational status changed to [[inverter_status]]

Oraz...

Battery
Stan ładowania baterii to ...
Energy Meter
Any phase is utilized above Utilization (%)%
Energy Meter
Phase ... is utilized above Utilization (%)%
Inverter
Daily yield is above Daily yield (kWh)
Inverter
Operational status contains Operational status
Inverter
Power is below Power (W)

Wtedy...

Energy Meter
Set the export limit to Limit (%)
i
The limit is set in percentage of the total power of all PV inverters connected to the Home Manager device. The Home Manager device needs to be configured for this to work.
Inverter
Ustaw moc docelową W
i
To również przełącza tryb mocy docelowej na Homey. W przypadku ładowarek EV ładowanie jest automatycznie uruchamiane lub zatrzymywane.
Inverter
Curtail active power to Percent (0–100) % of the manual power limit
i
Writes a curtailment percentage to register 40023. The value is applied as a fraction of the manual power limit (register 40915), e.g. 50 % of a 5000 W limit = 2500 W. This is SMA's intended pattern for repeated/automated power control and does NOT wear the flash memory. PREREQUISITES: External control must be enabled and a fallback value/time configured in EnnexOS or Sunny Portal beforehand. If no write occurs within the fallback time (typically 10 min), the inverter automatically returns to 100 %. Sufficient user rights (installer level) are required to enable external control.
Inverter
Limit the active power output to Power (W)
i
Writes the manual active power limit to the inverter's flash memory (register 40915). WARNING: SMA's flash memory has a finite write count. After ~1000 lifetime parameter writes the inverter restricts further changes to 1 per 20 operating hours, to protect the hardware from final damage. Use this action sparingly (e.g. one-time setup or rare adjustments). For continuous or flow-based control, use the 'Set active power curtailment (%)' action instead, which writes to a dedicated curtailment register without flash wear.

Widżety

Widżety tej aplikacji można dodać do pulpitu nawigacyjnego lub ekranu głównego w aplikacji mobilnej.

Realtime Energy Summary
Realtime Energy Summary

Pomoc

Masz problem z tą aplikacją? Skontaktuj się z twórcami aplikacji tutaj.

Nowości

Wersja 2.9.0 — New action 'Set active power curtailment (%)' for repeated/automated inverter control without flash memory wear (writes register 40023). Requires external control to be enabled in EnnexOS or Sunny Portal beforehand. The existing 'Limit the active power output' action remains for one-time setup; its hint now clearly warns about flash wear with repeated use.

Zobacz listę zmian

SMA Energy

SMA Energy nie jest kompatybilna z wybranym Homey.

SMA Energy zostanie wkrótce zainstalowana na Homey.
Zainstaluj