Stay connected with your Quatt heatpump and know when and how it's heating your home. With this Homey app, you can
use the sensor data from your Quatt heatpump to create flows to act on changes in the heatpump.
Note to Quatt Duo users: this app will show your Quatt heatpumps as a single device, but the values of both heatpumps
are available as separate sensor values.
Available sensor values:
- Central heating mode (boiler)
- Central heating active (cic)
- Central heating on/off (cic)
- Hot water active (boiler)
- Boiler flame on
- Boiler incoming water temperature
- Boiler outgoing water temperature
- Water flow speed (flowmeter)
- Water supply temperature (flowmeter)
- Supervisory control mode (quality control)
- Outside temperature (heatpump)
- Limited by COP (heatpump)
- Silent mode (heatpump)
- Heatpump incoming water temperature
- Heatpump outgoing water temperature
- Heatpump working mode
- Thermal power (heatpump)
- Power consumption (heatpump)
- Thermostat heating on
- Thermostat cooling on
- Thermostat hot water on
- Room temperature (thermostat)
- Room temperature setpoint (thermostat)
- Water supply temperature setpoint (thermostat)
Computed sensor values:
- Heatpump COP
- Heatpump water temperature difference
Czytaj więcej ›
Karty Flow
Kliknij na urządzenie powyżej, aby wyświetlić tylko powiązane karty Flow.
Kiedy...
Quatt
Zmiana w liczniku mocy
Quatt
CV is CV heating mode
Quatt
CV should Quatt CV heating command
Quatt
Boiler on/off mode should be Boiler on/off mode
Quatt
Hot water is Hot water in use
Quatt
Boiler flame is Boiler flame
Quatt
Boiler incoming water temperature changed
Quatt
Boiler outgoing water temperature changed
Quatt
Boiler water pressure has changed
Quatt
Water flow speed changed
Quatt
Boiler water supply temperature changed
Quatt
Coefficient of performance of Heatpump selection has changed
Quatt
Heatpump selection Limited
Quatt
Silent mode of Heatpump selection is Silent mode
Quatt
Water temperature delta of Heatpump selection has changed
Quatt
Incoming water temperature of Heatpump selection has changed
Quatt
Outgoing water temperature of Heatpump selection has changed
Quatt
Outside temperature measured by Heatpump selection has changed
Quatt
Thermal power of Heatpump selection has changed
Quatt
Working mode of Heatpump selection is: Working mode
Quatt
Supervisory Control Mode is: Working mode
Quatt
Thermostat is set to Cooling
Quatt
Thermostat warm water setting is set to Hot water
Quatt
Thermostat heating is set to Heating
Quatt
Current room temperature changed
Quatt
Room temperature setpoint changed
Quatt
Water supply temperature setpoint changed
Quatt Chill
Zmiana temperatury
Quatt Chill
Zmiana celu temperatury
Quatt Chill
Chill has an error
Quatt Chill
Chill status changed
Quatt Chill
Chill tank is full
Oraz...
Quatt
CV should be heating
Quatt
Boiler on/off setting is on
Quatt
Hot tap water is being used
Quatt
Boiler incoming water temperature is greater than Temperature (°C)
Quatt
Boiler outgoing water temperature is greater than Temperature (°C)
Quatt
Boiler water pressure is greater than Pressure (bar)
Quatt
Water flow speed is greater than Flow speed (L/h)
Quatt
Boiler water supply temperature is greater than Temperature (°C)
Quatt
Coefficient of performance of Heatpump selection is greater than COP
Quatt
Heatpump is limited by COP
Quatt
Heatpump selection is set to silent mode
Quatt
Water temperature delta of Heatpump selection is greater than Temperature (°C)
Quatt
Incoming water temperature of Heatpump selection is greater than Temperature (°C)
Quatt
Outgoing water temperature of Heatpump selection is greater than Temperature (°C)
Quatt
Outside temperature measured by Heatpump selection is greater than Temperature (°C)
Quatt
Thermal power of Heatpump selection is greater than Power (Watt)
Quatt
Working mode of Heatpump selection is Working mode
Quatt
Supervisory control mode is Supervisory control mode
Quatt
Thermostat cooling is on
Quatt
Thermostat hot water is on
Quatt
Thermostat is currently heating
Quatt
Current room temperature is greater than Temperature (°C)
Quatt
Room temperature setpoint is greater than Temperature (°C)
Quatt
Water supply temperature setpoint is greater than Temperature (°C)
Quatt Chill
Jest włączone
Wtedy...
Quatt
Set day sound level to Sound level
Quatt
Set night sound level to Sound level
Quatt
Turn pricing-based limiting State
Quatt Chill
Przełącz na wł. lub wył.
Quatt Chill
Ustaw temperaturę °C
Quatt Chill
Set fan mode to Fan mode
Quatt Chill
Set mode to Mode
Quatt Chill
Set target temperature to Temperature °C