Når …

intelligent-heat-pump
Ønsket temperatur ble endret
intelligent-heat-pump
Aktivert
intelligent-heat-pump
Deaktivert
intelligent-heat-pump
Vannstrømmen ble endret
intelligent-heat-pump
Strømmen ble endret
intelligent-heat-pump
Simulated target: [[simulated_target]]°C (Δ[[delta]]°C, conf: [[building_model_confidence]]%)
i
Triggers every control cycle (5 min) with full breakdown of what adaptive control calculates. Use for monitoring, logging, and confidence-based filtering. Filter on building_model_confidence to only act on high-confidence recommendations.
intelligent-heat-pump
Adaptive control [[status]]
i
Triggered when adaptive temperature control is enabled or disabled
intelligent-heat-pump
Ambient temperature changed Condition Temperature °C
i
Triggered when ambient temperature has changed above or below a specified level - useful for weather compensation
intelligent-heat-pump
New building insight detected
i
Triggers when building model detects actionable performance insight (≥70% confidence). Use tokens to filter by category and savings potential.
intelligent-heat-pump
Building profile mismatch detected
i
Triggers when learned building behavior significantly differs from selected profile (>30% deviation). Suggests optimal profile for faster learning.
intelligent-heat-pump
Cheapest [[hours]]-hour block started
i
Triggers when the cheapest electricity price block of the day starts. Use to maximize energy consumption during low-price periods.
intelligent-heat-pump
Coiler temperature Condition Temperature °C
i
Triggers when electricity coiler temperature goes above or below a specified level
intelligent-heat-pump
Compressor frequency Condition Frequency Hz (Expert)
i
Triggers when compressor frequency goes above or below a specified level. Requires 'Enable expert feature cards' in device settings.
intelligent-heat-pump
COP efficiency changed Condition COP threshold
i
Triggers when the Coefficient of Performance (COP) goes above or below a specified threshold
intelligent-heat-pump
COP outlier detected
i
Triggers when an invalid or suspicious COP value is detected, indicating potential sensor issues
intelligent-heat-pump
COP trend detected: Trend type
i
Triggers when COP shows a significant improving or degrading trend over the last 24 hours
intelligent-heat-pump
Daily consumption reached Daily threshold (kWh) kWh
i
Triggers when daily electricity consumption reaches specified threshold
intelligent-heat-pump
Daily COP efficiency changed Condition Daily COP threshold
i
Triggers when the 24-hour average COP goes above or below a specified threshold
intelligent-heat-pump
Daily cost exceeded €Cost threshold (€)
i
Triggers when today's total energy cost exceeds specified amount (requires price optimizer)
intelligent-heat-pump
Discharge temperature Condition Temperature °C
i
Triggers when discharge temperature goes above or below a specified level
intelligent-heat-pump
Economizer inlet temperature Condition Temperature °C
i
Triggers when economizer inlet temperature goes above or below a specified level
intelligent-heat-pump
Economizer outlet temperature Condition Temperature °C
i
Triggers when economizer outlet temperature goes above or below a specified level
intelligent-heat-pump
EEV pulse-steps Condition Pulse-steps
i
Triggers when Electronic Expansion Valve (EEV) pulse-steps go above or below a specified level
intelligent-heat-pump
EVI Open pulse-steps Condition Pulse-steps
i
Triggers when Enhanced Vapor Injection (EVI) pulse-steps go above or below a specified level
intelligent-heat-pump
Expensive period starts in [[warning_hours]] hour(s)
i
Triggers N hours before the most expensive electricity price block starts. Use to pre-heat or prepare before high-price periods.
intelligent-heat-pump
Fan motor frequency Condition Frequency Hz (Expert)
i
Triggers when fan motor frequency goes above or below a specified level. Requires 'Enable expert feature cards' in device settings.
intelligent-heat-pump
Fault code detected
i
Triggers when a system fault is detected
intelligent-heat-pump
Forecast heating advice available
i
Triggers when new COP-optimized heating advice is available based on temperature forecast
intelligent-heat-pump
Heating mode changed to [[mode]]
i
Triggers when the heating mode changes
intelligent-heat-pump
High pressure temperature Condition Temperature °C
i
Triggers when high pressure saturation temperature goes above or below a specified level
intelligent-heat-pump
Incoiler temperature Condition Temperature °C
i
Triggers when incoiler temperature goes above or below a specified level
intelligent-heat-pump
Inlet temperature changed Condition Temperature °C
i
Triggers when water inlet temperature goes above or below a specified level
intelligent-heat-pump
Building model reached [[milestone]] confidence
i
Triggers when the building thermal model reaches a learning milestone (e.g., 70% confidence)
intelligent-heat-pump
Low pressure temperature Condition Temperature °C
i
Triggers when low pressure saturation temperature goes above or below a specified level
intelligent-heat-pump
Monthly COP efficiency changed Condition Monthly COP threshold
i
Triggers when the 30-day average COP goes above or below a specified threshold
intelligent-heat-pump
Outlet temperature changed Condition Temperature °C
i
Triggers when water outlet temperature goes above or below a specified level
intelligent-heat-pump
Performance report is ready
i
Triggered daily at 23:00 with a comprehensive performance report. Use in combination with a notification action to receive daily performance summaries.
intelligent-heat-pump
Power consumption exceeded Power threshold (W) W
i
Triggers when power consumption exceeds specified threshold (requires power monitoring support)
intelligent-heat-pump
Pre-heating time recommendation
i
Triggers when ΔT (target - indoor) exceeds 1.5°C. Provides pre-heat duration based on building thermal response (τ). Requires ≥70% model confidence. Max once per 4 hours.
intelligent-heat-pump
Energy price became [[category]]
i
Triggers when energy price category changes (very_low, low, normal, high, very_high)
intelligent-heat-pump
Price trend changed from [[old_trend]] to [[new_trend]]
i
Triggers when electricity price trend direction changes (rising, falling, stable). Based on linear regression analysis with confidence threshold.
intelligent-heat-pump
Suction temperature Condition Temperature °C
i
Triggers when suction temperature goes above or below a specified level
intelligent-heat-pump
Tank temperature Condition Temperature °C
i
Triggers when water tank temperature goes above or below a specified level
intelligent-heat-pump
Adaptive control recommends [[recommended_temperature]]°C (conf: [[building_model_confidence]]%)
i
Triggered when adaptive control calculates a recommended temperature adjustment (only when significant action needed). Use building_model_confidence to filter on model confidence. Use 'Set target temperature' action to apply.
intelligent-heat-pump
Total consumption reached Consumption milestone (kWh) kWh
i
Triggers when total electricity consumption reaches specified milestones
intelligent-heat-pump
Water flow rate Condition Flow rate (L/min) L/min (Expert)
i
Triggers when water flow rate goes above or below a specified level. Requires 'Enable expert feature cards' in device settings.
intelligent-heat-pump
Water mode changed to [[mode]]
i
Triggers when the water control temperature mode changes
intelligent-heat-pump
Work mode changed to [[mode]]
i
Triggers when the work mode changes (ECO, Normal, Boost)

Og …

intelligent-heat-pump
Er slått på
intelligent-heat-pump
Hot water curve setting is Hot water curve setting
i
Check if the hot water curve setting matches the selected setting
intelligent-heat-pump
Compressor is running
i
Check if the compressor is currently running
intelligent-heat-pump
Model confidence is above Threshold (%)%
i
Check if building model confidence exceeds a threshold (0-100%). Use as quality gate for flows (e.g., only send notifications when confidence >80%).
intelligent-heat-pump
COP calculation method is Calculation method
i
Check which calculation method was used for the current COP value - useful for automation based on data availability
intelligent-heat-pump
COP efficiency is above COP threshold
i
Check if the current Coefficient of Performance (COP) is above or below a threshold
intelligent-heat-pump
COP trend is improving over Time period hours
i
Check the COP performance trend over a specified time period
intelligent-heat-pump
Daily COP is above Daily COP threshold
i
Check if the 24-hour average COP is above or below a threshold
intelligent-heat-pump
Device power is Power state
i
Check if the device power state matches the selected state
intelligent-heat-pump
3-phase electrical balance is within Balance tolerance % tolerance
i
Check if the 3-phase electrical currents are balanced within specified tolerance
intelligent-heat-pump
Fault is active
i
Check if a fault is currently active (fault code > 0)
intelligent-heat-pump
Heating curve setting is Heating curve
i
Check if the heating curve setting matches the selected curve
intelligent-heat-pump
Heating mode is Heating mode
i
Check if the heating mode matches the selected mode
intelligent-heat-pump
Hot water temperature is Comparison Hot water temperature °C
i
Check if the hot water temperature matches the specified condition
intelligent-heat-pump
Category insight is active
i
Check if a specific insight category is currently active (visible in capabilities). Returns false if dismissed or not detected.
intelligent-heat-pump
Monthly COP is above Monthly COP threshold
i
Check if the 30-day average COP is above or below a threshold
intelligent-heat-pump
Power consumption is above Power threshold (W) watts
i
Check if current power consumption is above or below a threshold (requires power monitoring support)
intelligent-heat-pump
Current hour is in cheapest Block size (hours) hours of today
i
Check if current hour is within the cheapest N-hour block today. Useful for running high-power tasks during low-price periods.
intelligent-heat-pump
Price trend for next Analysis window (hours) hours is Trend
i
Check if electricity prices are rising, falling, or stable in the next N hours. Based on linear regression with confidence metric.
intelligent-heat-pump
Current price is below daily average by Margin (%)%
i
Check if current electricity price deviates from the daily average by at least the specified margin percentage. Useful for detecting significantly low or high prices.
intelligent-heat-pump
Category savings are above €Threshold (EUR/month)/month
i
Check if estimated monthly savings for an insight category exceed a threshold (in EUR/month). Use for ROI-based filtering (e.g., only act on savings >€100/month).
intelligent-heat-pump
System pulse-steps differential is above Pulse-steps differential
i
Check if the pulse-steps difference between EEV and EVI is above or below a threshold
intelligent-heat-pump
Target (setpoint) temperature is Comparison Temperature °C
i
Check if the target (setpoint) temperature matches the specified condition
intelligent-heat-pump
Ambient temperature is above Temperature°C
i
Check if the ambient temperature is above or below a specific value
intelligent-heat-pump
Temperature differential is above Temperature differential °C
i
Check if the temperature difference between inlet and outlet is above or below a threshold
intelligent-heat-pump
Total consumption is above Consumption threshold (kWh) kWh
i
Check if total electricity consumption is above or below a threshold
intelligent-heat-pump
Electricity consumption checking is Comparison Electricity consumption checking
i
Check if the electricity consumption checking level matches the specified condition
intelligent-heat-pump
Water flow rate is above Flow rate (L/min) L/min
i
Check if water flow rate is above or below specified threshold
intelligent-heat-pump
Water control mode is Comparison Water control mode
i
Check if the water control mode matches the specified condition
intelligent-heat-pump
Work mode is Work mode
i
Check if the work mode matches the selected mode

Så …

intelligent-heat-pump
Innstill temperaturen °C
intelligent-heat-pump
Slå på
intelligent-heat-pump
Slå av
intelligent-heat-pump
Veksle mellom på og av
intelligent-heat-pump
Calculate value via Input Value using curve rules Curve Definition
i
Calculates output values based on input (e.g., outdoor temperature → heating setpoint). Format: '[operator] threshold : value'. Operators: >, >=, <, <=, ==, !=. Evaluates top to bottom, returns first match. Use 'default : value' as fallback. Example heating curve: '< 0 : 55, < 5 : 50, < 10 : 45, default : 35'
Advanced
intelligent-heat-pump
Calculate heating curve: L29=L29: Set temp at -15°C outdoor (°C)°C at -15°C, L28=L28: Slope grade (per 10°C)/10°C with outdoor temp Outdoor Temperature
i
Calculates supply temperature using Adlar Custom heating curve. Uses L29 (set temp at -15°C) and L28 (slope grade per 10°C). Example: L29=55°C at -15°C with L28=-5 gives slope -0.5/°C, formula y = -0.5x + 47.5. For outdoor temp 5°C → supply temp 45°C.
Advanced
intelligent-heat-pump
Calculate when to start heating to reach Target indoor temperature (°C)°C at Ready at (HH:MM)
i
Calculate when to start heating to reach the desired indoor temperature at a specific time. Uses the building model's thermal time constant (τ) for accurate prediction.
Advanced
intelligent-heat-pump
Calculate value from time periods Time schedule
i
Evaluates current time against a daily schedule to calculate output values. Perfect for time-based temperature scheduling, time-of-use pricing, and automated daily routines.
Advanced
intelligent-heat-pump
Force insight analysis
i
Immediately evaluate building insights (without waiting for 50-minute interval). Returns number of insights detected and current model confidence.
Advanced
intelligent-heat-pump
Generate performance report
i
Generate a comprehensive heat pump performance report with scores across 7 domains (efficiency, building, defrost, energy, pricing, telemetry, health). Returns overall score, rating, and actionable recommendations.
Advanced
intelligent-heat-pump
Get seasonal mode
i
Returns heating/cooling mode based on current date. Heating season: Oct 1 - May 15 (aligned with EN 14825 SCOP standard). Perfect for automatically switching between winter and summer schedules.
Advanced
intelligent-heat-pump
Send Ambient temperature (°C)°C to heat pump for COP/thermal mass calculation
i
Sends ambient temperature data to the heat pump for enhanced COP/thermal mass calculations
intelligent-heat-pump
Send external energy prices Energy prices (JSON) for price optimization
i
Sends hourly energy prices (€/kWh) from external source to enable price-based optimization. Accepts two formats: Array [0.11,0.10,...] where index=hour offset (0=current hour), or Object {"0":0.11,"1":0.10,...} with hour keys.
intelligent-heat-pump
Send Water flow rate (L/min)L/min to heat pump for COP calculation
i
Sends water flow data to the heat pump for enhanced COP calculations
intelligent-heat-pump
Send Indoor temperature (°C)°C indoor temperature for adaptive control
i
Sends current indoor/room temperature from an external sensor to enable adaptive temperature control
intelligent-heat-pump
Send Power consumption (W)W to heat pump for COP calculation
i
Sends power consumption data to the heat pump for enhanced COP calculations
intelligent-heat-pump
Send solar power Solar panel power (W)W to heat pump
i
Sends solar panel output for accurate solar radiation calculation. Use with SolarEdge, Enphase, etc.
intelligent-heat-pump
Send solar radiation Solar radiation (W/m²) W/m² to heat pump
i
Sends solar radiation data for building model. Use with KNMI weather app.
intelligent-heat-pump
Send wind speed Wind speed (km/h) km/h to heat pump
i
Sends wind speed data for heat loss correction. Use with KNMI weather app.
intelligent-heat-pump
Set hot water curve setting to Hot water curve setting
i
Set the hot water curve setting for optimal efficiency
intelligent-heat-pump
Set device power to Power state
i
Set the device power state
intelligent-heat-pump
Set heating curve setting to Heating curve setting
i
Set the heating curve setting
intelligent-heat-pump
Set heating mode to Heating mode
i
Set the heating operation mode
intelligent-heat-pump
Set hot water temperature to Hot water temperature (°C)
i
Set the hot water temperature setting
intelligent-heat-pump
Set target (setpoint) temperature to Temperature (°C) If decimal value
i
Set the target (setpoint) temperature for the heat pump
intelligent-heat-pump
Set electricity consumption checking to Electricity consumption checking
i
Set the electricity consumption checking level
intelligent-heat-pump
Set water control mode to Water control mode
i
Set the water control mode setting
intelligent-heat-pump
Set work mode to Work mode
i
Set the system work mode