Advarsel! Denne appen fungerer kanskje ikke som den skal.
Denne appen er under testing, og har aldri blitt anmeldt. Den fungerer kanskje ikke som forventet. Vær ekstra forsiktig når du installerer denne appen.
« Tilbake til standardversjonen
Instantly monitor the battery state of charge, power consumption, power harvest from PV, and mains. Create a flow to get notified if there is an alarm or a warning.
Build control flows to disable or limit the power of the inverter if a car is charging. Easily control the switch position (mode) of your system; Charger Only, Inverter Only, On or Off. All Victron Energy Storage Systems (ESS) standard actions are supported.
Les mer ›
Støttede enheter
Battery
Energy Meter
EV Charger
Generator
PV Inverter
Solar Charger
Tank sensor
Temperature sensor
Victron GX
Victron VRM
Flow-kort
Klikk på en enhet ovenfor for å kun vise relaterte Flow-kort.
Når …
Battery
Batterinivået ble endret
Battery
Batteriladingsstatusen ble endret ...
Battery
Den generelle alarmen ble aktivert
Battery
Den generelle alarmen ble deaktivert
Battery
Strømmen ble endret
Battery
Spenningen ble endret
Battery
Den elektriska strømmen ble endret
Battery
Temperaturen endres
Energy Meter
Strømmen ble endret
Energy Meter
Strømmåleren ble endret
Energy Meter
Grid surplus changed to [[power]] / [[single_phase]] / [[three_phase]]
EV Charger
Strømmen ble endret
EV Charger
Den elektriska strømmen ble endret
EV Charger
Strømmåleren ble endret
EV Charger
Status changed to [[status]]
PV Inverter
Strømmen ble endret
Solar Charger
Strømmen ble endret
Solar Charger
Den elektriska strømmen ble endret
Solar Charger
Spenningen ble endret
Solar Charger
Strømmåleren ble endret
Tank sensor
Status changed to [[status]]
Tank sensor
Tank level changed to [[level]]
Temperature sensor
Temperaturen endres
Temperature sensor
Luftfuktigheten ble endret
Temperature sensor
Trykket ble endret
Temperature sensor
Spenningen ble endret
Temperature sensor
Status changed to [[status]]
Victron GX
Strømmen ble endret
Victron GX
Alarm status changed to [[status]] with [[alarms]] and [[warnings]]
Victron GX
Dynamic ESS mode changed to Mode
Victron GX
Input source changed to [[source]]
Victron GX
Switch position changed
Victron GX
VE Bus status changed to [[status]]
Og …
Battery
Batteriladingsstatusen er ...
Battery
Den generelle alarmen er på
Battery
Time since last full charge is less than Time (seconds)
Victron GX
AC inputs are below Power (W)
Victron GX
AC loads are below Power (W)
Victron GX
AC outputs are below Power (W)
Victron GX
Max charge current is Condition Current (A)
Victron GX
Consumption power is below Power (W)
Victron GX
Excess solar power is below Power (W)
Victron GX
Max grid feed-in power is Condition Power (W)
Victron GX
Grid power is below Power (W)
Victron GX
Grid setpoint is Condition Power (W)
Victron GX
Input source is Source
Victron GX
Max discharge power is Condition Power (W)
Victron GX
Min SoC is Condition SoC (%)
Victron GX
Scheduled charging is enabled for schedule Schedule
Victron GX
Solar power is below Power (W)
Victron GX
Switch position is Mode
Victron GX
VE Bus status is Status
Så …
EV Charger
Veksle mellom på og av
EV Charger
Set EV charger max current to Current (A)
EV Charger
Set EV charger mode to Mode
Victron GX
Create charging schedule Schedule for Day at Start time with duration Duration or SoC SoC
Victron GX
Disable charging schedule Schedule
Victron GX
Enable charging schedule Schedule
Victron GX
Limit charge current to Current (A)
Victron GX
Limit grid feed-in power to Power (W)
Victron GX
Limit AC import to Current (A) when peakshaving
Victron GX
Limit discharge power to Power (W)
Victron GX
Set batteryLife state to Mode
Victron GX
Set dynamic ESS mode to Mode
Victron GX
Set multiphase regulation state to Mode
Victron GX
Switch relay 1 to State
Victron GX
Switch relay 2 to State
Victron GX
Set switch position to Mode
Victron GX
Update grid setpoint to Power (W)
Victron GX
Update minimum SoC to SoC (%)
Støtte
Har du et problem med denne appen?
Kontakt utvikleren her .
Nyheter
Versjon 1.4.1 — New action for setting the dynamic ESS mode
Vis endringslogg