Zone Control

PI-based zone light controller with target lux, occupancy afterglow, and smooth fades.
PI-based zone light controller with target lux, occupancy afterglow, and smooth fades.

자세히 읽기 ›

지원되는 디바이스

Flow 카드

위의 디바이스를 클릭하면 관련 Flow 카드만 표시됩니다.

언제...

Curve (per zone)
Curve output changed
i
Fires when the curve output value changes.
Zone Controller
켜지면
Zone Controller
꺼지면
Zone Controller
밝기가 변경되면
Zone Controller
조도가 변경되면
Zone Controller
Light level changed (0-100%)
i
Fires when the zone light level changes.
Zone Controller
Unoccupied (left)
i
Fires when the zone becomes unoccupied.
Zone Controller
Occupied (entered)
i
Fires when the zone becomes occupied.
Zone Controller
Zone active again (cancel timers)
i
Fires when the zone re-enters active state and timers are cancelled.
Zone Controller
Zone inactive (fade)
i
Fires when afterglow fade starts; token is the fade duration.
Zone Controller
Zone inactive (off delay)
i
Fires when off-delay is scheduled; token is seconds until off.

그리고...

Zone Controller
켜지면
Zone Controller
Zone is in afterglow
i
Returns true while the zone is in FADE or HOLD afterglow.
Zone Controller
Zone is occupied
i
Returns true when occupancy is active.
Zone Controller
Mode is ...
i
Checks if control mode equals the selected value.

그러면...

Curve (per zone)
Set input (lux) = Lux
i
Feed a raw input value to the curve device.
Curve (per zone)
Set curve points (JSON) = Points (JSON)
i
Provide an array of {"x":..,"y":..} points in JSON.
Zone Controller
켜기
Zone Controller
끄기
Zone Controller
켬/끔 상태 전환하기
Zone Controller
다음 밝기로 조절 %
Zone Controller
상대 밝기 설정 %
i
제품의 현재 디밍 수준에 따라 어둡게 또는 밝게 설정돼요.
Zone Controller
Set measured lux (PV) = Lux lx
i
Override/update the measured lux for the zone controller.
Zone Controller
Set mode = Mode
i
Switch control mode (auto/manual/on/off/night).
Zone Controller
Set occupied = Occupied
i
Sets occupancy state (true/false).
Zone Controller
Set light level = Lysniveau (%)%
i
Directly set output in Manual/On modes (clamped by UMAX).
Zone Controller
Set PID: Kp=... Ti=... Td=... β=... N=...
i
Optionally provide any subset of PID parameters.
Zone Controller
Set target lux = Lux lx
i
Set the lux setpoint for PI control.
Zone Controller
Set max output to ...%
i
Set the maximum output limit (%).
Zone Controller
Set min output to ...%
i
Set the minimum output limit (%).

지원

이 앱의 개발자는 직접 지원을 제공하지 않습니다.

새로운 기능

버전 3.0.2 — Minor changes to flow cards

업데이트 로그 보기