HR-energy

Control your Qube heatpump from Homey
Control your Qube heatpump from Homey

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Qube
L'allarme generico è stato attivato
Qube
L'allarme generico è stato disattivato
Qube
L'energia è cambiata
Qube
Alarm state changed
i
Triggers when any alarm turns ON or OFF. The alarm name and state are provided as tags.
Qube
COP changed
i
Triggers when the Coefficient of Performance (COP) changes.
Qube
DHW temperature changed
i
Triggers when the domestic hot water temperature changes.
Qube
Heating ΔT changed
i
Triggers when the heating circuit temperature difference (supply - return) changes.
Qube
Outdoor temperature changed
i
Triggers when the outdoor temperature changes.
Qube
Electric power changed
i
Triggers when the electric power consumption changes.
Qube
Return temperature changed
i
Triggers when the return temperature changes.
Qube
Room temperature changed
i
Triggers when the room temperature changes.
Qube
Source ΔT changed
i
Triggers when the source-side temperature difference (source in - source out) changes.
Qube
Source in temperature changed
i
Triggers when the source inlet temperature changes.
Qube
Source out temperature changed
i
Triggers when the source outlet temperature changes.
Qube
Supply temperature changed
i
Triggers when the supply temperature changes.
Qube
Thermal power changed
i
Triggers when the thermal power output changes.
Qube
Unit status changed
i
Triggers when the heat pump unit status changes (e.g. standby → heating). Only fires when the decoded status text changes.

E...

Qube
L'allarme generico è acceso
Qube
Alarm Alarm is State
i
Checks whether the selected alarm is currently ON or OFF.
Qube
COP is Operator Value
i
Checks whether the current Coefficient of Performance (COP) matches the selected condition.
Qube
DHW temperature is Operator Value °C
i
Checks whether the current domestic hot water temperature matches the selected condition.
Qube
Heating ΔT is Operator Value (°C) °C
i
Checks whether the heating circuit temperature difference (supply - return) matches the selected condition.
Qube
Outdoor temperature is Operator Value °C
i
Checks whether the current outdoor temperature matches the selected condition.
Qube
Electric power is Operator Value (W) W
i
Checks whether the current electric power consumption matches the selected condition.
Qube
Return temperature is Operator Value °C
i
Checks whether the current return temperature matches the selected condition.
Qube
Room temperature is Operator Value °C
i
Checks whether the current room temperature matches the selected condition.
Qube
Source ΔT is Operator Value (°C) °C
i
Checks whether the source-side temperature difference (source in - source out) matches the selected condition.
Qube
Source in temperature is Operator Value °C
i
Checks whether the current source inlet temperature matches the selected condition.
Qube
Source out temperature is Operator Value °C
i
Checks whether the current source outlet temperature matches the selected condition.
Qube
Supply temperature is Operator Value °C
i
Checks whether the current supply temperature matches the selected condition.
Qube
Thermal power is Operator Value (W) W
i
Checks whether the current thermal power output matches the selected condition.
Qube
Unit status is Status
i
Checks whether the current heat pump unit status matches the selected status.

Poi...

Qube
Force anti-legionella cycle
i
The heat pump will heat the DHW tank to high temperature (often ~60°C). This is limited to once per day.
Qube
Force DHW program
i
Forces the DHW time program to run once, this overrides normal schedule.
Qube
Set BMS demand control to Status
i
ON means that heat pump is allowed to run and OFF means that heat pump demand is removed. This is used by building management systems. Do not toggle frequently and do not combine with LinQ control.
Qube
Set cooling Period setpoint to Temperature °C
i
Sets the room cooling setpoint for the selected period (day or night). These setpoints are used only when the internal thermostat control of the heat pump is active. If the system is controlled by an external thermostat, BMS/Modbus demand or heating curve compensation, these setpoints may not affect the heat pump operation.
Qube
Set DHW program to Status
i
Enables or disables the DHW time program via BMS (TapW_TimeProgram.BMS_ForceTimeProgram).
Qube
Set DHW setpoint to Temperature °C
i
Sets the domestic hot water temperature setpoint (TapW_TimeProgram.DHWS). This is the minimum DHW tank temperature that the heat pump will maintain.
Qube
Set heating curve to State
i
Enable or disable the weather-dependent heating curve. When enabled, the supply temperature setpoint is automatically adjusted based on outdoor temperature.
Qube
Set heating Period setpoint to Temperature °C
i
Sets the room heating setpoint for the selected period (day or night). These setpoints are used only when the internal thermostat control of the heat pump is active. If the system is controlled by an external thermostat, BMS/Modbus demand or heating curve compensation, these setpoints may be ignored.
Qube
Set season mode to Season
i
Switch between heating (winter) and cooling (summer) season. It is also used by LinQ and do not overwrite frequently.
Qube
Set SG Ready mode to SG Ready mode
i
SG Ready is a smart-grid interface used by many heat pumps. It allows the electricity grid or a controller to influence operation. Off: Normal operation. Block: Do not run compressor. Plus: Preheat slightly. Max: Run aggressively to store energy.
Qube
Write Value to Modbus register Register address as Data type
i
Write a raw value to a Modbus holding register. For advanced / debugging use only. Incorrect values may cause unexpected behavior.

Supporto

Hai un problema con questa app? Contatta lo sviluppatore qui.