Unisciti alla nostra festa di compleanno. Solo questa settimana, ogni 10° Homey Pro o Homey Bridge è gratuito!
Manage your solar power

Leggi di più ›

Dispositivi supportati

Schede dei Flow

Clicca su un dispositivo qui sopra per visualizzare solo le schede dei Flow correlate.

Quando...

Battery monitor
Il livello della batteria è cambiato
Battery monitor
Il voltaggio è cambiato
Battery monitor
La temperatura è cambiata
HPS
Il livello della batteria è cambiato
HPS
Firmware has been updated
i
Is triggered as soon as a new firmware version has been installed on the home power station
HPS
Maximum charging power has been changed
i
Is triggered as soon as the maximum possible charging power has changed
HPS
Maximum discharging power has been changed
i
Is triggered as soon as the maximum possible discharging power has changed
HPS
Manual battery charging started
i
Is triggered as soon as manual storage loading has been started
HPS
Manual storage charging ended or stopped
i
Triggered as soon as a manual storage loading is completed or canceled
HPS
Island operation (emergency power) started
i
Is triggered as soon as the home power station has switched to stand-alone operation. This is done as part of the emergency power function
HPS
Island operation (emergency power) beendet
i
Is triggered as soon as the home power station has switched back to normal operation. This is done as part of the emergency power function
HPS
The emergency power reserve has been changed
i
Is triggered as soon as the set emergency power reserve has changed

E...

HPS
The max. charging power is greater than Charging limit Unit
HPS
The max. discharging power is greater than Discharging limit Unit
HPS
The maximum charging power is currently limited
HPS
The maximum discharging power is currently limited
HPS
The maximum charging power and/or the maximum discharging power is currently limited
HPS
Manual battery charging is active
HPS
The set emergency power reserve is larger than Reserve Unit
HPS
Island mode is active
HPS
Island mode is possible
i
Checks whether island operation is possible. The card only returns 'Yes' if the following conditions are met: The home power station is not in stand-alone mode. The home power station reports that the emergency power function is available and the home power station must report that switching is possible

Poi...

HPS
Sets the maximum charge limit of the home power station to Charging limit Unit
i
Sets the maximum charging limit of the home power station and activates the settings. If, for example, the battery can be charged with 7000W according to the home power station, the value is limited to 5000W here and there is more than 5000W of excess PV power, the battery is charged correspondingly more slowly. The values must be within the permissible values of the home power station. If they are not, the card will fail.
Advanced
HPS
Remove the maximum charging limit of the home power station
i
Removes any existing charging limit from the home power station.
Advanced
HPS
Sets the maximum discharge limit of the home power station to Discharging limit Unit
i
Sets the maximum discharge limit of the home power station and activates the settings. If, for example, the battery can be discharged with 7000W according to the home power station, the value is limited to 5000W here and the home consumption is more than 5000W, the battery is still only discharged with a maximum of 5000W. The difference is usually compensated by the grid or the PV surplus. The values must be within the permissible values of the home power station. If they do not, the card will fail.
Advanced
HPS
Remove the maximum discharging limit of the home power station
i
Removes any existing discharging limit from the home power station.
Advanced
HPS
Remove all charging and discharging limits
i
Remove all charging and discharging limits and reset them to the default values
Advanced
HPS
Provide the current charging configuration
i
Reads out the charging configuration currently set on the home power station and makes the values available as tokens in the flow
Advanced
HPS
Activate the charge/discharge limits currently set on the home power station
i
Activates the charge and discharge limit configuration stored in the home power station
Advanced
HPS
Deactivate the charge/discharge limits currently set on the home power station
i
Deactivates the charging and discharging limit configuration stored in the home power station. The values are retained. Only the function itself is deactivated
Advanced
HPS
Charge Amount of energy Wh additionally into the battery
i
A manual charging process is started. The specified amount of energy in Wh is charged in addition to the current charge level (up to max. 100%). Attention: With most home power stations, manual storage charging can only be triggered once a day
HPS
Charge the battery to approximately Target charge level%
i
A manual charging process is started. The battery is charged to approximately the specified percentage value. Attention: With most home power stations, manual storage charging can only be triggered once a day
HPS
Stops a manual charging process
i
If a manual charging process is running, it is stopped when this card is executed
HPS
Set the emergency power reserve to ReserveUnit
i
Sets the emergency power reserve of the home power station
HPS
Removes the emergency power reserve
i
Removes the emergency power reserve of the home power station. After executing the card, the entire battery capacity is available for normal energy supply

Supporto

Hai un problema con questa app? Contatta lo sviluppatore inviando un'email.

Novità

Versione 1.0.5 — - Hotfix: New devices could not be added. Sorry!

Visualizza il changelog

E3DC - HPS

E3DC - HPS non è compatibile con l'Homey selezionato.

E3DC - HPSverrà installato a breve su Homey.
Installa