RAMSES ESP

Let your home ventilation respond to CO₂, humidity and your daily routine.

Warning! This app might not work properly.

This app version is currently being tested, and has not yet been reviewed. It might not work as expected.
Be extra careful when installing this app.

« Back to the regular version

Let your home ventilation respond to CO₂, humidity and your daily routine.

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

Ramses Gateway
A packet was received
i
Fires for every packet on the bus.
Ramses Gateway
A 22F1 packet was received from or to * or 29:123456
i
Address * matches any device.
Ramses Gateway
A new device was found on the bus
Ramses Gateway
The gateway went offline
Ramses Gateway
The gateway came online
Remote
The ... button was pressed
Remote
Any button was pressed
Room sensor
The ... button was pressed
Room sensor
Any button was pressed
Ventilation unit
The fan mode changed
Ventilation unit
The fan mode changed to ...
Ventilation unit
A boost started
Ventilation unit
The unit reported a fault
Ventilation unit
The fault of the unit is gone
Ventilation unit
The filter needs replacing
Virtual CO₂ sensor
The CO₂-level changed
Virtual CO₂ sensor
The humidity changed

And...

Ramses Gateway
The gateway is online
Ventilation unit
The fan mode is ...
Ventilation unit
The unit has fault

Then...

Ramses Gateway
Send frame I --- 29:173894 29:233244 --:------ 22F1 003 000304
i
A complete RAMSES II frame, e.g. I --- 29:173894 29:233244 --:------ 22F1 003 000304
Ramses Gateway
Send ... 31DA with payload 00 to 29:123456
i
Sent from the gateway's own address.
Ventilation unit
Set the fan mode to ...
Ventilation unit
Run on high for 30 minutes
Ventilation unit
Reset the filter counter
Ventilation unit
Ask the unit for its status
Ventilation unit
Set the bypass to ...
Ventilation unit
Set Parameter to Value
i
For heat recovery units with parameters.
Virtual CO₂ sensor
Report ppm ppm CO₂
i
Use a CO₂ value from any Homey sensor; the unit treats it as its own sensor.
Virtual CO₂ sensor
Report % % humidity
Virtual CO₂ sensor
Ask the unit for % % ventilation
i
In auto mode the unit ventilates more as the demand rises.

Widgets

You can add this app’s widgets to your dashboard or homescreen in the mobile app.

Ventilation
Ventilation

Support

Having an issue with this app? Report issues via the developer issue tracker.

What’s new

Version 1.0.5 — New app image and a picture of the real device for each driver, so you can see at a glance which one to add. Shorter app description.

View changelog

RAMSES ESP

RAMSES ESP is not compatible with the selected Homey.

RAMSES ESP will install on Homey shortly.
Install App