Ostrzeżenie! Ta aplikacja może nie działać prawidłowo.
Ta wersja aplikacji jest obecnie testowana i nikt nie wystawił opinii na jej temat. Aplikacja może nie działać zgodnie z oczekiwaniami. Podczas jej instalowania zachowaj szczególną ostrożność.
Eurotronic Technology GmbH is mostly known for their thermostatic valves.
With our latest Z-Wave thermostatic valve, the Comet 700, being the first thermostatic valve with the Z-Wave 700 chipset.
A state of the art thermostatic valve, in looks and functionality.
Making it even more easy to transform every single room in your home, into a warm and comfortable place.
But we don't only offer thermostats anymore, we also have started to create environmental sensors.
Not only to make every room comfortable, but to also support a healthier living environment.
And we now also proudly present our magnet-less(!) Door and Window sensor.
To "automatically" turn off your thermostat, if a window or door is open for too long.
Or even announce that a window should be opened!
Without having to care about that usual magnet.
Currently the app only supports our Z-Wave devices, our Zigbee thermostat will be supported a future release.
Kliknij na urządzenie powyżej, aby wyświetlić tylko powiązane karty Flow.
Kiedy...
Air Quality Sensor
Zmiana poziomu stężenia CO2
Air Quality Sensor
Zmiana temperatury
Air Quality Sensor
Zmiana wilgotności
Air Quality Sensor
Dewpoint has changed
Air Quality Sensor
The air quality has changed
Air Quality Sensor
The air quality has changed to Quality
Air Quality Sensor
The volatile organic compound (VOC) has changed
Comet 700 Thermostat
Zmiana poziomu naładowania baterii
Comet 700 Thermostat
Zmiana temperatury
Comet 700 Thermostat
Zmiana celu temperatury
Comet 700 Thermostat
A valve error has occurred
Comet 700 Thermostat
Manual position changed
Comet 700 Thermostat
The (child) protection state changed
Comet 700 Thermostat
Thermostatic mode has changed
Comet 700 Thermostat
Thermostatic mode has changed to Mode
Comet 700 Thermostat
Manual position changed
Comet Thermostat
Zmiana poziomu naładowania baterii
Comet Thermostat
Zmiana temperatury
Comet Thermostat
Zmiana celu temperatury
Comet Thermostat
Thermostatic mode has changed
Comet Thermostat
Thermostatic mode has changed to Mode
Comet Thermostat
Manual position changed
Door/Window Sensor
Zmiana poziomu naładowania baterii
Door/Window Sensor
Alarm otwarcia włączony
Door/Window Sensor
Alarm otwarcia wyłączony
Spirit Thermostat
Zmiana poziomu naładowania baterii
Spirit Thermostat
Zmiana temperatury
Spirit Thermostat
Zmiana celu temperatury
Spirit Thermostat
A valve error has occurred
Spirit Thermostat
Manual position changed
Spirit Thermostat
Thermostatic mode has changed
Spirit Thermostat
Thermostatic mode has changed to Mode
Spirit Thermostat
The (child) protection state changed
Stella Thermostat
Zmiana poziomu naładowania baterii
Stella Thermostat
Zmiana temperatury
Stella Thermostat
Zmiana celu temperatury
Stella Thermostat
Thermostatic mode has changed
Stella Thermostat
Thermostatic mode has changed to Mode
Stella Thermostat
Manual position changed
Temperature/Humidity Sensor
Zmiana poziomu naładowania baterii
Temperature/Humidity Sensor
Zmiana temperatury
Temperature/Humidity Sensor
Zmiana wilgotności
Temperature/Humidity Sensor
Dewpoint has changed
Oraz...
Air Quality Sensor
The air quality is Quality
Comet 700 Thermostat
The (child) protection state is State
Comet 700 Thermostat
Thermostat mode is Mode
Comet Thermostat
Thermostat mode is Mode
Door/Window Sensor
Alarm otwarcia włączony
Spirit Thermostat
Thermostat mode is Mode
Spirit Thermostat
The (child) protection state is State
Stella Thermostat
Thermostat mode is Mode
Wtedy...
Comet 700 Thermostat
Ustaw temperaturę °C
Comet 700 Thermostat
Set thermostatic position to Value
i
This will set the manual thermostatic's valve position.
0 = closed, 250 = fully open.
Comet 700 Thermostat
Set economy temperature to Degree Celsius
i
This sets the temperature for the Economy mode
Comet 700 Thermostat
Set (child) protection to State
i
With this card you can set the (child) protection state.
You can unlock it by holding the plus and minus buttons.
Comet 700 Thermostat
Set thermostat mode to Mode
i
Set the mode of the thermostatic
Comet Thermostat
Ustaw temperaturę °C
Comet Thermostat
Set thermostat mode to Mode
i
Set the mode of the thermostatic
Comet Thermostat
Set economic temperature to Degree Celsius
i
This sets the temperature for the Economy mode
Comet Thermostat
Set thermostatic position to Percentage
i
This will set the manual thermostatic's valve position.
0% = fully closed, 100% = fully open.
Spirit Thermostat
Ustaw temperaturę °C
Spirit Thermostat
Set economy temperature to Degree Celsius
i
This sets the temperature for the Economy mode
Spirit Thermostat
Set the room temperature to TemperatureºC
i
Send an (external) temperature to the spirit so it knows the room temperature.
The setting "(External) Room Temperature" does need to be active to use this.
Spirit Thermostat
Set thermostatic position to Percentage
i
This will set the manual thermostatic's valve position.
0% = fully closed, 100% = fully open.
Spirit Thermostat
Set (child) protection to State
i
With this card you can set the (child) protection state.
You can unlock it by holding the plus and minus buttons.
Spirit Thermostat
Set thermostat to Mode
i
Set the mode of the thermostatic
Stella Thermostat
Ustaw temperaturę °C
Stella Thermostat
Set thermostat mode to Mode
i
Set the mode of the thermostatic
Stella Thermostat
Set economic temperature to Degree Celsius
i
This sets the temperature for the Economy mode
Stella Thermostat
Set thermostatic position to Percentage
i
This will set the manual thermostatic's valve position.
0% = fully closed, 100% = fully open.
Pomoc
Masz problem z tą aplikacją?
Skontaktuj się z twórcami aplikacji tutaj.