GivEnergy

Monitor and control your solar energy system locally
Monitor and control your solar energy system locally

Czytaj więcej ›

Obsługiwane urządzenia

Karty Flow

Kliknij na urządzenie powyżej, aby wyświetlić tylko powiązane karty Flow.

Kiedy...

Battery
Zmiana mocy
Battery
Zmienił się poziom baterii
Battery
Zmiana temperatury
GivEnergy
Grid frequency dropped below Frequency (Hz)Hz
GivEnergy
Grid frequency rose above Frequency (Hz)Hz
GivEnergy
Grid voltage dropped below Voltage (V)V
GivEnergy
Grid voltage rose above Voltage (V)V
Grid Meter
Zmiana mocy
Solar Inverter
Zmiana mocy
Solar Inverter
Zmiana w liczniku mocy

Oraz...

Battery
Battery is charging
i
True when the battery is being charged.
Battery
Battery is discharging
i
True when the battery is being discharged.
Solar Inverter
Eco mode is enabled
i
True when the inverter is operating in eco mode.
Solar Inverter
Grid is exporting
i
True when exporting power to the grid.
Solar Inverter
Grid is importing
i
True when importing power from the grid.
Solar Inverter
Solar is generating
i
True when solar panels are producing power.

Wtedy...

Solar Inverter
Action charge schedule
i
Enables or disables the battery charge schedule.
Solar Inverter
Action discharge schedule
i
Enables or disables the battery discharge schedule.
Solar Inverter
Force charge to Target SOC (%)% at Charge Rate (%)% rate
i
Enables timed charge with a full-day slot, forcing the battery to charge from the grid. Use 'Stop force charge' to restore previous settings.
Solar Inverter
Force discharge at Discharge Rate (%)% rate, reserve Battery Reserve (%)%
i
Enables timed export with a full-day slot, forcing the battery to discharge to the grid. Use 'Stop force discharge' to restore previous settings.
Solar Inverter
Set battery pause mode to Mode
i
Pauses battery charge, discharge, or both. Gen3 inverters only.
Solar Inverter
Set charge rate to Watts W
i
Sets the battery charge rate in watts.
Solar Inverter
Set charge slot 1 to Start Time (HH:MM) - End Time (HH:MM)
i
Configures the charge schedule time window. Gen1/Gen2 inverters support 1 charge slot.
Solar Inverter
Set charge slot Slot to Start Time (HH:MM) - End Time (HH:MM) at Target SOC (%)%
i
Configures a charge schedule slot with target SOC. Gen3 inverters support slots 1-3.
Solar Inverter
Set discharge rate to Watts W
i
Sets the battery discharge rate in watts.
Solar Inverter
Set discharge slot Slot to Start Time (HH:MM) - End Time (HH:MM)
i
Configures a discharge schedule time window. Gen1/Gen2 inverters support slots 1-2.
Solar Inverter
Set discharge slot Slot to Start Time (HH:MM) - End Time (HH:MM) at Target SOC (%)%
i
Configures a discharge schedule slot with target SOC. Gen3 inverters support slots 1-3.
Solar Inverter
Set export limit to Watts W
i
Sets the grid export limit in watts. Gen3 inverters only.
Solar Inverter
Stop force charge
i
Restores inverter charge settings to their state before 'Force charge from grid' was used.
Solar Inverter
Stop force discharge
i
Restores inverter discharge settings to their state before 'Force discharge to grid' was used.
Solar Inverter
Action eco mode
i
Enables or disables eco mode (HR27). Independent of timed export.
Solar Inverter
Action timed export
i
Enables or disables timed export (HR59). Independent of eco mode.

Pomoc

Masz problem z tą aplikacją? Skontaktuj się z twórcami aplikacji tutaj.

Nowości

Wersja 1.4.0 — Multiple charge/discharge slots, force charge/discharge actions, energy event triggers, daily

Zobacz listę zmian

GivEnergy

GivEnergy nie jest kompatybilna z wybranym Homey.

GivEnergy zostanie wkrótce zainstalowana na Homey.
Zainstaluj