Avertissement ! Cette appli peut ne pas fonctionner correctement.
Cette appli est en cours de test, et n’a jamais été revue. Il se peut qu’elle ne fonctionne pas comme attendu. Prenez des précautions supplémentaires en installant cette appli.
« Retour à la version normale
Homey app to receive realtime data from your SolarEdge, Growatt, Sungrow, Huawei, Kostal, Solax & Wattsonic solar installation using local Modbus TCP
Purpose
The difference of this app and the already existing solar panels app is that this app reads the data directly from the inverter.
The SolarEdge api is for example limited to 300 calls a day, so you get only updates every 10-15 minutes.
The modbus app receives data every few 20 seconds.
If you have an energy monitor installed you can maximize your self-consumption and limit your exported power by consuming it. You can make flows based on your generated solar power, exported power, imported power or current power consumption.
Following devices are supported
- Solaredge Inverters with SetApp and with display with or without Modbus energy Meter
- Solaredge StorEdge devices (DC connected battery storage)
- Growatt - SPA, SPH or TL-X XXX Hybrid Inverter and others in the same range using local Modbus TCP, follow this doc https://www.dropbox.com/s/584915enkxc508u/Setup%20Growatt.pdf?dl=0
- Wattsonic gen3 inverter and their clones (sunways, solinteg, A-Tronix, St-ems). following this blog Wattsonic Hybrid Inverter Gen3 Modbus RTU Protocol https://smarthome.exposed/wattsonic-hybrid-inverter-gen3-modbus-rtu-protocol/
- Sungrow Hybrid and with battery
- Huawei Hybrid and with battery, also double Huawei with s-dongle
- Solax with battery
- Kostal with battery
- Sigenergy with battery
Lire plus ›
Appareils pris en charge
Growatt + Battery
Growatt Inverter
Growatt TL-X + Battery
Huawei 2 Inverters S-Dongle + Battery
Huawei EMMA
Huawei Inverter
Huawei Inverter + Battery
Kostal Inverter
Sigenergy + Battery
Solaredge + Storedge
Solaredge Inverter
Solax + Battery
SolaxUltra + Battery
Sungrow Hybrid + Battery
Sungrow String
Wattsonic + Battery
Wattsonic Inverter
Cartes Flow
Cliquez sur un appareil ci-dessus pour afficher uniquement les cartes Flow associées.
Quand...
Growatt + Battery
L'énergie a changé
Growatt + Battery
Le compteur électrique a changé
Growatt + Battery
Le niveau de la batterie a changé
Growatt + Battery
The solar power changed
Growatt + Battery
Total Yield changed
Growatt Inverter
L'énergie a changé
Growatt Inverter
Le compteur électrique a changé
Growatt Inverter
The solar power changed
Growatt Inverter
Total Yield changed
Growatt TL-X + Battery
L'énergie a changé
Growatt TL-X + Battery
Le compteur électrique a changé
Growatt TL-X + Battery
Le niveau de la batterie a changé
Huawei 2 Inverters S-Dongle + Battery
L'énergie a changé
Huawei 2 Inverters S-Dongle + Battery
Le compteur électrique a changé
Huawei 2 Inverters S-Dongle + Battery
Le voltage a changé
Huawei 2 Inverters S-Dongle + Battery
Le niveau de la batterie a changé
Huawei EMMA
L'énergie a changé
Huawei EMMA
Le niveau de la batterie a changé
Huawei EMMA
Le compteur électrique a changé
Huawei EMMA
The solar power changed
Huawei EMMA
Total Yield changed
Huawei Inverter
L'énergie a changé
Huawei Inverter
Le compteur électrique a changé
Huawei Inverter
Le voltage a changé
Huawei Inverter
The solar power changed
Huawei Inverter
Total Yield changed
Huawei Inverter + Battery
L'énergie a changé
Huawei Inverter + Battery
Le compteur électrique a changé
Huawei Inverter + Battery
Le niveau de la batterie a changé
Huawei Inverter + Battery
The solar power changed
Huawei Inverter + Battery
Total Yield changed
Kostal Inverter
L'énergie a changé
Kostal Inverter
Le compteur électrique a changé
Kostal Inverter
Le niveau de la batterie a changé
Kostal Inverter
The solar power changed
Kostal Inverter
Total Yield changed
Sigenergy + Battery
L'énergie a changé
Sigenergy + Battery
Le niveau de la batterie a changé
Sigenergy + Battery
The solar power changed
Sigenergy + Battery
Total Yield changed
Solaredge + Storedge
Le niveau de la batterie a changé
Solaredge + Storedge
L'énergie a changé
Solaredge + Storedge
Le courant électrique a changé
Solaredge + Storedge
Le compteur électrique a changé
Solaredge + Storedge
Status changed
Solaredge + Storedge
The electric current changed
Solaredge + Storedge
The solar power changed
Solaredge + Storedge
The inverter temperature changed
Solaredge + Storedge
Total Yield changed
Solaredge + Storedge
Total Day Yield changed
Solaredge + Storedge
Storage Control Mode has changed
Solaredge + Storedge
Storage Charge/Discharge Mode has changed
Solaredge + Storedge
Battery Charge Changed
Solaredge + Storedge
Battery status changed
Solaredge + Storedge
Power Export Changed (W)
Solaredge + Storedge
Power Import Changed (W)
Solaredge + Storedge
Consumption Changed
Solaredge + Storedge
The battery temperature changed
Solaredge + Storedge
Total Import Yield changed
Solaredge + Storedge
Total Export Yield changed
Solaredge + Storedge
The grid import power changed
Solaredge + Storedge
The grid export power changed
Solaredge + Storedge
The battery discharge power changed
Solaredge + Storedge
The battery charge power changed
Solaredge + Storedge
Le niveau de la batterie a changé
Solaredge Inverter
L'énergie a changé
Solaredge Inverter
Le courant électrique a changé
Solaredge Inverter
Le compteur électrique a changé
Solaredge Inverter
Status changed
Solaredge Inverter
The electric current changed
Solaredge Inverter
The solar power changed
Solaredge Inverter
The inverter temperature changed
Solaredge Inverter
Total Yield changed
Solaredge Inverter
Total Day Yield changed
Solax + Battery
L'énergie a changé
Solax + Battery
Le compteur électrique a changé
Solax + Battery
Le niveau de la batterie a changé
SolaxUltra + Battery
L'énergie a changé
SolaxUltra + Battery
Le compteur électrique a changé
SolaxUltra + Battery
Le niveau de la batterie a changé
Sungrow Hybrid + Battery
L'énergie a changé
Sungrow Hybrid + Battery
Le compteur électrique a changé
Sungrow Hybrid + Battery
Le niveau de la batterie a changé
Sungrow Hybrid + Battery
The solar power changed
Sungrow Hybrid + Battery
The inverter temperature changed
Sungrow Hybrid + Battery
Total Yield changed
Sungrow Hybrid + Battery
Total Day Yield changed
Sungrow Hybrid + Battery
Load Yield changed
Sungrow Hybrid + Battery
Grid Import changed
Sungrow Hybrid + Battery
Grid Export changed
Sungrow String
L'énergie a changé
Sungrow String
La température a changé
Sungrow String
Le compteur électrique a changé
Sungrow String
The solar power changed
Sungrow String
Total Yield changed
Sungrow String
Total Day Yield changed
Wattsonic + Battery
L'énergie a changé
Wattsonic + Battery
Le compteur électrique a changé
Wattsonic + Battery
Le niveau de la batterie a changé
Wattsonic Inverter
L'énergie a changé
Wattsonic Inverter
Le compteur électrique a changé
Wattsonic Inverter
The solar power changed
Wattsonic Inverter
Total Yield changed
Et...
Growatt + Battery
Grid charging is ...
Growatt + Battery
Export limit is ...
Growatt + Battery
Inverter priority is ...
Growatt Inverter
Export limit is ...
Growatt TL-X + Battery
Grid charging is ...
Growatt TL-X + Battery
Export limit is ...
Growatt TL-X + Battery
Inverter priority is ...
Solaredge + Storedge
Inverter status is ...
Solaredge + Storedge
Battery is higher than ...
Solaredge + Storedge
Battery charging is higher than ...
Solaredge + Storedge
Battery discharging is higher than ...
Solaredge + Storedge
Grid export is higher than ...
Solaredge + Storedge
Grid import is higher than ...
Solaredge + Storedge
Inverter + Battery is higher than ...
Solaredge + Storedge
Battery status is ...
Solaredge + Storedge
Storage Control Mode is ...
Solaredge + Storedge
Storage Charge/Discharge Mode is ...
Solaredge Inverter
Inverter status is ...
Solaredge Inverter
Inverter power is higher than ...
Solax + Battery
Use Mode is ...
Solax + Battery
Storage Charge/Discharge mode is ...
Sungrow Hybrid + Battery
Power limitation is ...
Sungrow Hybrid + Battery
Inverter is ...
Sungrow String
Power limitation is ...
Sungrow String
Inverter is ...
Wattsonic + Battery
Battery is higher than ...
Alors...
Growatt + Battery
Set Battery AC charge switch to ...
Growatt + Battery
Set Battery First Maximum SoC to Maximum SoC(%)
Growatt + Battery
Set Grid First Battery Minimum SoC to Minimum SoC(%)
Growatt + Battery
Set export limit to ...
Growatt + Battery
Set Export limit to Export Limit(%)
Growatt + Battery
Set Priority mode to ...
Growatt + Battery
Sync Invertor Clock, including date: Set Date as well
Growatt + Battery
Set Grid First for the next Hours hours at discharge rate Discharge Rate(%) and min SoC Minimum SoC(%)
Growatt + Battery
Set Battery First for the next Hours hours at charge rate Max Charge rate(%) and max SoC Max Battery SoC(%) with AC charge AC charge enabled
Growatt + Battery
Set Load first Battery Minimum Capacity to Load First minimum SoC(%)
Growatt + Battery
Set Grid First Battery Discharge Rate to Discharge Rate(%)
Growatt + Battery
Set Batt First Battery Charge Rate to Charge Rate(%)
Growatt + Battery
Battery First, time slot 1: Start Time ~ Stop Time state: ...
Growatt + Battery
Grid First, time slot 1: Start Time ~ Stop Time state: ...
Growatt + Battery
Battery First, time slot 2: Start Time ~ Stop Time state: ...
Growatt + Battery
Battery First, time slot 3: Start Time ~ Stop Time state: ...
Growatt + Battery
Grid First, time slot 2: Start Time ~ Stop Time state: ...
Growatt + Battery
Grid First, time slot 3: Start Time ~ Stop Time state: ...
Growatt Inverter
Set export limit to ...
Growatt Inverter
Set Export limit to Export Limit(%)
Growatt TL-X + Battery
Set Battery AC charge switch to ...
Growatt TL-X + Battery
Set Battery First Maximum SoC to Maximum SoC(%)
Growatt TL-X + Battery
Set Grid First Battery Minimum SoC to Minimum SoC(%)
Growatt TL-X + Battery
Set export limit to ...
Growatt TL-X + Battery
Set Export limit to Export Limit(%)
Growatt TL-X + Battery
Sync Invertor Clock, including date: Set Date as well
Growatt TL-X + Battery
Time slot 1: Hour Minute Hour Minute state: ...
Growatt TL-X + Battery
Time slot 2: Hour Minute Hour Minute state: ...
Growatt TL-X + Battery
Time slot 3: Hour Minute Hour Minute state: ...
Growatt TL-X + Battery
Time slot 4: Hour Minute Hour Minute state: ...
Huawei 2 Inverters S-Dongle + Battery
Storage working mode setting device id ...
Huawei 2 Inverters S-Dongle + Battery
Remote charge/discharge control mode device id ...
Huawei 2 Inverters S-Dongle + Battery
Storage forcible charge/discharge device id ...
Huawei 2 Inverters S-Dongle + Battery
Active power control mode device id ...
Huawei 2 Inverters S-Dongle + Battery
Storage excess pv device id ...
Huawei EMMA
Battery Control ...
Huawei EMMA
Power control mode at grid ...
Huawei Inverter + Battery
Storage working mode setting ...
Huawei Inverter + Battery
Remote charge/discharge control mode ...
Huawei Inverter + Battery
Storage forcible charge/discharge ...
Huawei Inverter + Battery
Active power control mode ...
Huawei Inverter + Battery
Storage excess pv ...
Sigenergy + Battery
Remote EMS control mode ...
Sigenergy + Battery
Remote EMS ...
Solaredge + Storedge
Set Active Power Limit to percentage
Solaredge + Storedge
Set Export Limit to ...
Solaredge + Storedge
Set Limit mode to ...
Solaredge + Storedge
Set Storage Control Mode to ...
Solaredge + Storedge
Set Storage Charge/Discharge Mode to ...
Solaredge + Storedge
Set Charge power to ...
Solaredge + Storedge
Set Discharge power to ...
Solaredge Inverter
Set Active Power Limit to percentage
Solaredge Inverter
Set Power reduce Limit to percentage
Solax + Battery
Set Feedin Power to Power
Solax + Battery
Set User Export Power to Power
Solax + Battery
Use mode ...
Solax + Battery
Set Storage Charge/Discharge Mode to ...
Sungrow Hybrid + Battery
Adjust Power limitation Power
Sungrow Hybrid + Battery
Set power limitation ...
Sungrow Hybrid + Battery
Set Power limitation setting to Limit(%)
Sungrow Hybrid + Battery
Set inverter to ...
Sungrow Hybrid + Battery
Hybrid Inverter Working Mode ...
Sungrow Hybrid + Battery
Set export limit ... ...
Sungrow Hybrid + Battery
Charge/discharge ... ...
Sungrow String
Adjust Power limitation Power
Sungrow String
Set power limitation ...
Sungrow String
Set Power limitation setting to Limit(%)
Sungrow String
Set inverter to ...
Wattsonic + Battery
Hybrid Inverter Working Mode ...
Assistance
Vous avez un problème avec cette appli ?
Contacter le développeur ici .
Nouveautés
Version 3.0.206 — growat sph battery & sungrow, solax ultra, sungrow battery, huawei emma changes
Afficher le journal des modifications