HR-energy

Control your Qube heatpump from Homey
Control your Qube heatpump from Homey

Leer más ›

Dispositivos compatibles

Tarjetas Flow

Haz clic en el dispositivo de arriba para mostrar solo las tarjetas Flow relacionadas.

Cuando...

Qube
La potencia ha cambiado
Qube
La alarma general se ha activado
Qube
La alarma general se ha desactivado
Qube
Any alarm turned ON
i
Triggers when any alarm activates. The alarm name is provided as a tag.
Qube
Compressor shutting down
i
Triggers when the compressor begins its shutdown sequence.
Qube
Compressor start failed
i
Triggers when a compressor start attempt has failed.
Qube
Compressor starting
i
Triggers when the compressor begins its startup sequence.
Qube
Cooling alarm turned ON
i
Triggers when a cooling alarm activates.
Qube
DHW timeout alarm turned ON
i
Triggers when domestic hot water heating exceeds the maximum allowed time.
Qube
Entered alarm/fault
i
Triggers when the heat pump enters an alarm or fault state.
Qube
Entered cooling
i
Triggers when the heat pump enters cooling mode.
Qube
Entered DHW heating
i
Triggers when the heat pump starts domestic hot water production.
Qube
Entered heating
i
Triggers when the heat pump enters heating mode.
Qube
Entered standby
i
Triggers when the heat pump enters standby mode.
Qube
Flow alarm turned ON
i
Triggers when insufficient flow is detected on the heating circuit.
Qube
Global alarm turned OFF
i
Triggers when the global alarm clears.
Qube
Global alarm turned ON
i
Triggers when the global alarm activates.
Qube
Heating alarm turned ON
i
Triggers when a heating circuit alarm activates.
Qube
Legionella timeout alarm turned ON
i
Triggers when the anti-legionella cycle fails to reach target temperature in time.
Qube
Source-side alarm turned ON
i
Triggers when a source/brine circuit alarm activates.
Qube
Unit status changed
i
Triggers when the heat pump unit status changes (e.g. standby → heating).
Qube
User-side alarm turned ON
i
Triggers when a user-side (load) alarm activates.
Qube
Working hours alarm turned ON
i
Triggers when a maintenance threshold (operating hours limit) has been reached.

Y...

Qube
La alarma general está activada

Entonces...

Qube
Force DHW program Force DHW
i
Force the domestic hot water time program via BMS.
Qube
Set cooling setpoint to Temperature °C
i
Write the cooling supply temperature setpoint.
Qube
Set demand to Demand
i
Enable or disable heat pump demand via Modbus.
Qube
Set DHW setpoint to Temperature °C
i
Write the domestic hot water temperature setpoint.
Qube
Set heating curve to State
i
Enable or disable the heating curve (weather-dependent setpoint).
Qube
Set heating setpoint to Temperature °C
i
Write the heating supply temperature setpoint.
Qube
Set season mode to Season
i
Switch between heating (winter) and cooling (summer) season.
Qube
Set SG Ready mode to SG Ready mode
i
Set the SG Ready mode. Controls two internal boolean switches (sgready_a / sgready_b).
Qube
Start anti-legionella cycle
i
Manually triggers an anti-legionella disinfection cycle.
Qube
Write Value to Modbus register Register address as Data type
i
Write a raw value to a Modbus holding register. For advanced / debugging use.

Asistencia

¿Tienes algún problema con esta aplicación? Contacta con el desarrollador aquí.

Novedades

Versión 1.0.2 — Added developer support links.

Ver registro de cambios