Join our 10th birthday celebration. This week only, every 10th Homey Pro or Homey Bridge is free!

Quatt

Know when your Quatt heatpump is heating your house
Know when your Quatt heatpump is heating your house

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

Quatt
The power changed
Quatt
CV is CV heating mode
i
This card starts when the CV is (not) heating.
Quatt
CV should Quatt CV heating command
i
This card triggers when Quatt CiC's command to the CV whether to start heating or not changes.
Quatt
Boiler on/off mode should be Boiler on/off mode
i
Only valid for on/off boilers (non-modulating). This card triggers when Quatt CiC's command to the boiler whether to turn on or off changes.
Quatt
Hot water is Hot water in use
i
This card starts when hot tap water is used.
Quatt
Boiler flame is Boiler flame
i
This card starts when the boiler flame switches from on -> off or vice versa.
Quatt
Boiler incoming water temperature changed
i
This card starts when the temperature of the water going into the boiler has changed.
Quatt
Boiler outgoing water temperature changed
i
This card starts when the temperature of the water coming out of the boiler has changed.
Quatt
Water flow speed changed
i
This card starts when the current flow rate of the water in the heating circuit has changed.
Quatt
Boiler water supply temperature changed
i
This card starts when the current temperature of the water supplied to the boiler has changed.
Quatt
Coefficient of performance of Heatpump selection has changed
i
This card starts when the coefficient of performance of the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Heatpump selection Limited
i
This card starts whenever value indicating that the heatpump is limited by COP changes. The heatpump might be limited by the COP (Coefficient of Performance) based on energy pricing, current ambient temperature and heat pump outlet temperature. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Silent mode of Heatpump selection is Silent mode
i
This card starts whenever the heatpump switches from silent mode. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Water temperature delta of Heatpump selection has changed
i
This card starts when the water temperature delta of the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Incoming water temperature of Heatpump selection has changed
i
This card starts when the current temperature of the water going into the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Outgoing water temperature of Heatpump selection has changed
i
This card starts when the current temperature of the water coming out of the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Outside temperature measured by Heatpump selection has changed
i
This card starts when the current ambient temperature outside the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Thermal power of Heatpump selection has changed
i
This card starts when the thermal power output of the heatpump has changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Working mode of Heatpump selection is: Working mode
i
This card starts whenever the current working mode of the heatpump is changed. If you only have one heatpump, the selection of the heatpump doesn't matter (1/2 can be used interchangeably).
Quatt
Supervisory Control Mode is: Working mode
i
This card starts whenever the current supervisory control mode of the heatpump is changed.
Quatt
Thermostat is set to Cooling
i
This card starts whenever the setting in the thermostat whether to enable cooling or not has changed.
Quatt
Thermostat warm water setting is set to Hot water
i
This card starts whenever the thermostat setting to enable/disable hot tap water has changed.
Quatt
Thermostat heating is set to Heating
i
This card starts whenever the value representing the command from thermostat to switch on heating has changed.
Quatt
Current room temperature changed
i
This card starts when the current temperature of the room as measured by the thermostat has changed. If you have a multiroom thermostat system, this will be your central thermostat that is connected to your boiler/CV.
Quatt
Room temperature setpoint changed
i
This card starts when the current setpoint temperature for the room as set by your central thermostat has changed.
Quatt
Water supply temperature setpoint changed
i
This card starts when the current setpoint for water supply temperature as set by your central thermostat has changed.

And...

Quatt
CV is heating
i
Whether the CV is currently heating (actual state, not the Quatt CiC's command)
Quatt
CV should be heating
i
Quatt CiC's command to the CV whether to start heating.
Quatt
Boiler on/off setting is on
i
Only valid for on/off boilers (non-modulating). This condition is for the Quatt CiC's command to turn an on/off boiler on or off.
Quatt
Hot tap water is being used
i
Whether hot tap water is currently being used.
Quatt
Boiler flame is on
Quatt
Boiler incoming water temperature is greater than Temperature (°C)
Quatt
Boiler outgoing water temperature is greater than Temperature (°C)
Quatt
Water flow speed is greater than Flow speed (L/h)
Quatt
Boiler water supply temperature is greater than Temperature (°C)
i
The temperature of the water supply to the boiler as measured by the flow meter.
Quatt
Coefficient of performance of Heatpump selection is greater than COP
i
The COP is a ratio. A value > 1 means that the heatpump delivers more thermal power than the electrical power it consumes. If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Heatpump is limited by COP
i
Whether the heatpump is limited by the COP. It might be limited by the COP (Coefficient of Performance) based on energy pricing, current ambient temperature and heat pump outlet temperature.
Quatt
Heatpump selection is set to silent mode
i
If you only have one heatpump, you can leave the selection heatpump (i.e. it doesn't matter which selection you pick).
Quatt
Water temperature delta of Heatpump selection is greater than Temperature (°C)
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Incoming water temperature of Heatpump selection is greater than Temperature (°C)
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Outgoing water temperature of Heatpump selection is greater than Temperature (°C)
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Outside temperature measured by Heatpump selection is greater than Temperature (°C)
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Thermal power of Heatpump selection is greater than Power (Watt)
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Working mode of Heatpump selection is Working mode
i
If you only have one heatpump, you can leave the selection on any/all/1 heatpump.
Quatt
Supervisory control mode is Supervisory control mode
Quatt
Thermostat cooling is on
Quatt
Thermostat hot water is on
i
Whether the CV is currently set to supply hot tap water, which is regulated by the thermostat's setting for hot water.
Quatt
Thermostat is currently heating
i
Whether the thermostat command is currently set to heat or not.
Quatt
Current room temperature is greater than Temperature (°C)
Quatt
Room temperature setpoint is greater than Temperature (°C)
Quatt
Water supply temperature setpoint is greater than Temperature (°C)

Support

Having an issue with this app? Contact the developer here.

What's new

Version 1.2.3 — Incorrect value for 'off' capabilities

View changelog

Quatt

Quatt is not compatible with the selected Homey.

Quatt will install on Homey shortly.
Install App