HR-energy

Control your Qube heatpump from Homey
Control your Qube heatpump from Homey

Read more ›

Supported devices

Flow cards

Click on a device above to show related Flow cards only.

When...

Qube
The power changed
Qube
The generic alarm turned on
Qube
The generic alarm turned off
Qube
Any alarm turned ON
i
Triggers when any alarm activates. The alarm name is provided as a tag.
Qube
Compressor shutting down
i
Triggers when the compressor begins its shutdown sequence.
Qube
Compressor start failed
i
Triggers when a compressor start attempt has failed.
Qube
Compressor starting
i
Triggers when the compressor begins its startup sequence.
Qube
Cooling alarm turned ON
i
Triggers when a cooling alarm activates.
Qube
DHW timeout alarm turned ON
i
Triggers when domestic hot water heating exceeds the maximum allowed time.
Qube
Entered alarm/fault
i
Triggers when the heat pump enters an alarm or fault state.
Qube
Entered cooling
i
Triggers when the heat pump enters cooling mode.
Qube
Entered DHW heating
i
Triggers when the heat pump starts domestic hot water production.
Qube
Entered heating
i
Triggers when the heat pump enters heating mode.
Qube
Entered standby
i
Triggers when the heat pump enters standby mode.
Qube
Flow alarm turned ON
i
Triggers when insufficient flow is detected on the heating circuit.
Qube
Global alarm turned OFF
i
Triggers when the global alarm clears.
Qube
Global alarm turned ON
i
Triggers when the global alarm activates.
Qube
Heating alarm turned ON
i
Triggers when a heating circuit alarm activates.
Qube
Legionella timeout alarm turned ON
i
Triggers when the anti-legionella cycle fails to reach target temperature in time.
Qube
Source-side alarm turned ON
i
Triggers when a source/brine circuit alarm activates.
Qube
Unit status changed
i
Triggers when the heat pump unit status changes (e.g. standby → heating).
Qube
User-side alarm turned ON
i
Triggers when a user-side (load) alarm activates.
Qube
Working hours alarm turned ON
i
Triggers when a maintenance threshold (operating hours limit) has been reached.

And...

Qube
The generic alarm is on

Then...

Qube
Force DHW program Force DHW
i
Force the domestic hot water time program via BMS.
Qube
Set cooling setpoint to Temperature °C
i
Write the cooling supply temperature setpoint.
Qube
Set demand to Demand
i
Enable or disable heat pump demand via Modbus.
Qube
Set DHW setpoint to Temperature °C
i
Write the domestic hot water temperature setpoint.
Qube
Set heating curve to State
i
Enable or disable the heating curve (weather-dependent setpoint).
Qube
Set heating setpoint to Temperature °C
i
Write the heating supply temperature setpoint.
Qube
Set season mode to Season
i
Switch between heating (winter) and cooling (summer) season.
Qube
Set SG Ready mode to SG Ready mode
i
Set the SG Ready mode. Controls two internal boolean switches (sgready_a / sgready_b).
Qube
Start anti-legionella cycle
i
Manually triggers an anti-legionella disinfection cycle.
Qube
Write Value to Modbus register Register address as Data type
i
Write a raw value to a Modbus holding register. For advanced / debugging use.

Support

Having an issue with this app? Contact the developer here.